Page 57 of 75 
 
TP10110019-ST  
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No.: IECEN60065G 
 
 
 
7.1 
TABLE: temperature rise measurements 
 
Power consumption in the OFF/Stand-by 
OFF: 0 W 
 
 
Position of the functional switch (W) ......................ON: 31.4 W (108 V) 
31.5 W (132 V) 
— 
Operating conditions 
Test voltage: 120 x 0.9 = 108 Vac; 120 V x 1.1 = 132 Vac (T2, UST-FOR-YOU / F02801610) 
Un (Vac) 
In (A) 
Pn (W) 
Pout (W) 
108 
0.592 
31.4 
 
132 
0.525 
31.5 
 
Monitored point: 
dT (K) 
Limit dT (K) 
Input voltage  
108 Vac 
132 Vac 
-- 
1. 
CN1 body 
24.6 
24.0 
50 
2. 
PCB nera TH1 
28.8 
27.5 
70 
3. 
CX1 body 
25.7 
24.8 
65 
4. 
CX2 body 
25.5 
24.5 
65 
5. 
LF1 coil 
26.3 
25.1 
70 
6. 
LF2 coil 
25.8 
24.6 
70 
7. 
CY1 body 
22.3 
21.9 
50 
8. 
CY2 body 
20.2 
19.9 
50 
9. 
CY3 body 
24.4 
23.8 
50 
10.  PCB near BR1 
27.6 
26.8 
70 
11.  C1 body near BR1 
35.8 
34.8 
50 
12.  PCB between Q6 & Q7 
54.1 
51.1 
70 
13.  T2 coil 
59.7 
58.5 
65 
14.  T2 core 
64.2 
52.9 
65 
15.  CT1 coil 
62.2 
61.1 
65 
16.  DT1 coil 
46.0 
45.2 
65 
17.  DT1 core 
41.9 
41.4 
65 
18.  T1 coil 
56.8 
57.8 
65 
19.  T1 core 
53.6 
54.1 
65 
20.  CY4 body 
48.9 
48.4 
50 
21.  U2 body 
49.3 
49.1 
65 
22.  PCB naer U1 
50.1 
48.3 
70 
23.  L2 coil 
29.6 
30.6 
70 
24.  PCB near IC1 
32.7 
32.8 
70 
25.  L1 coil 
33.0 
32.9 
70 
26.  C17 body 
32.7 
32.5 
70 
27.  Plastic enclosure inside near T2 
26.3 
26.2 
-- 
28.  Wooden enclosure inside near T2 
9.3 
9.9 
60 
29.  Metal enclosure outside near power 
13.8 
14.0 
40 
 
 
 
 
 
Winding temperature rise measurements 
 
 
Ambient temperature t1 (
o
C)  ................................
22.3 
— 
 
Ambient temperature t2 (
o
C)  ................................
21.5 
— 
 
 
 
 
Page 58 of 75 
 
TP10110019-ST  
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No.: IECEN60065G 
 
 
 
7.1 
TABLE: temperature rise measurements 
 
Power consumption in the OFF/Stand-by 
OFF: 0 W 
 
 
Position of the functional switch (W) ......................ON: 31.9 W (198 V) 
31.9 W (253 V) 
— 
Operating conditions 
Test voltage: 220 x 0.9 = 198 Vac; 230 V x 1.1 = 253 Vac (T2, UST-FOR-YOU / F02801610) 
Un (Vac) 
In (A) 
Pn (W) 
Pout (W) 
198 
0.349 
31.9 
 
253 
0.296 
31.9 
 
Monitored point: 
dT (K) 
Limit dT (K) 
Input voltage  
198 Vac 
253 Vac 
-- 
1. 
CN1 body 
20.7 
21.2 
50 
2. 
PCB nera TH1 
18.9 
19.3 
70 
3. 
CX1 body 
19.6 
20.2 
65 
4. 
CX2 body 
19.8 
20.1 
65 
5. 
LF1 coil 
21.0 
21.3 
70 
6. 
LF2 coil 
20.1 
20.9 
70 
7. 
CY1 body 
17.8 
18.2 
50 
8. 
CY2 body 
16.8 
17.3 
50 
9. 
CY3 body 
19.7 
20.0 
50 
10.  PCB near BR1 
21.0 
21.4 
70 
11.  C1 body near BR1 
28.9 
29.7 
50 
12.  PCB between Q6 & Q7 
39.2 
42.2 
70 
13.  T2 coil 
50.9 
52.2 
65 
14.  T2 core 
50.2 
51.2 
65 
15.  CT1 coil 
49.5 
51.9 
65 
16.  DT1 coil 
38.0 
40.2 
65 
17.  DT1 core 
37.6 
39.6 
65 
18.  T1 coil 
49.7 
54.8 
65 
19.  T1 core 
48.5 
53.1 
65 
20.  CY4 body 
43.7 
46.1 
50 
21.  U2 body 
43.2 
45.8 
65 
22.  PCB naer U1 
40.0 
43.4 
70 
23.  L2 coil 
27.4 
30.2 
70 
24.  PCB near IC1 
27.0 
27.8 
70 
25.  L1 coil 
32.3 
33.4 
70 
26.  C17 body 
27.2 
28.5 
70 
27.  Plastic enclosure inside near T2 
19.7 
20.7 
-- 
28.  Wooden enclosure inside near T2 
6.7 
6.9 
60 
29.  Metal enclosure outside near power 
12.4 
12.6 
40 
 
 
 
 
 
Winding temperature rise measurements 
 
 
Ambient temperature t1 (
o
C)  ................................
23.2 
— 
 
Ambient temperature t2 (
o
C)  ................................
23.2 
— 
 
 
 
 
Page 59 of 75 
 
TP10110019-ST  
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No.: IECEN60065G 
 
 
 
7.1 
TABLE: temperature rise measurements 
 
Power consumption in the OFF/Stand-by 
OFF: 0 W 
 
 
Position of the functional switch (W) ......................ON: 25.8 W (108 V) 
25.9 W (132 V) 
— 
Operating conditions 
Test voltage: 120 x 0.9 = 108 Vac; 120 V x 1.1 = 132 Vac (T2, EASE HOUSE LIMITED / NT1810NL) 
Un (Vac) 
In (A) 
Pn (W) 
Pout (W) 
108 
0.441 
25.8 
 
132 
0.39 
25.9 
 
Monitored point: 
dT (K) 
Limit dT (K) 
Input voltage  
108 Vac 
132 Vac 
-- 
1. 
CN1 body 
19.7 
19.8 
50 
2. 
PCB nera TH1 
25.3 
24.5 
70 
3. 
CX1 body 
17.9 
17.9 
65 
4. 
CX2 body 
18.3 
18.2 
65 
5. 
LF1 coil 
20.2 
19.8 
70 
6. 
LF2 coil 
18.0 
17.8 
70 
7. 
CY1 body 
16.3 
16.5 
50 
8. 
CY2 body 
15.3 
15.6 
50 
9. 
CY3 body 
17.6 
17.8 
50 
10.  PCB near BR1 
19.3 
19.4 
70 
11.  C1 body near BR1 
26.7 
26.9 
50 
12.  PCB between Q6 & Q7 
42.8 
43.2 
70 
13.  T2 coil 
52.6 
52.6 
65 
14.  T2 core 
49.7 
49.7 
65 
15.  CT1 coil 
52.4 
53.4 
65 
16.  DT1 coil 
37.5 
38.2 
65 
17.  DT1 core 
33.2 
33.9 
65 
18.  T1 coil 
47.4 
50.3 
65 
19.  T1 core 
48.7 
52.2 
65 
20.  CY4 body 
41.0 
42.2 
50 
21.  U2 body 
43.7 
45.5 
65 
22.  PCB naer U1 
43.5 
45.7 
70 
23.  L2 coil 
24.1 
25.6 
70 
24.  PCB near IC1 
26.5 
27.0 
70 
25.  L1 coil 
30.0 
30.5 
70 
26.  C17 body 
26.5 
27.1 
70 
27.  Plastic enclosure inside near T2 
18.4 
18.9 
-- 
28.  Wooden enclosure inside near T2 
6.6 
7.2 
60 
29.  Metal enclosure outside near power 
13.1 
13.7 
40 
 
 
 
 
 
Winding temperature rise measurements 
 
 
Ambient temperature t1 (
o
C)  ................................
19.0 
— 
 
Ambient temperature t2 (
o
C)  ................................
18.7 
— 
 
 
 
 
Page 60 of 75 
 
TP10110019-ST  
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No.: IECEN60065G 
 
 
 
7.1 
TABLE: temperature rise measurements 
 
Power consumption in the OFF/Stand-by 
OFF: 0 W 
 
 
Position of the functional switch (W) ......................ON: 25.3 W (198 V) 
25.8 W (253 V) 
— 
Operating conditions 
Test voltage: 220 x 0.9 = 198 Vac; 230 V x 1.1 = 253 Vac (T2, EASE HOUSE LIMITED / NT1810NL) 
Un (Vac) 
In (A) 
Pn (W) 
Pout (W) 
198 
0.284 
25.3 
 
253 
0.243 
25.8 
 
Monitored point: 
dT (K) 
Limit dT (K) 
Input voltage  
198 Vac 
253 Vac 
-- 
1. 
CN1 body 
18.6 
18.4 
50 
2. 
PCB nera TH1 
21.6 
21.0 
70 
3. 
CX1 body 
16.9 
16.9 
65 
4. 
CX2 body 
17.2 
17.0 
65 
5. 
LF1 coil 
18.5 
18.3 
70 
6. 
LF2 coil 
16.9 
16.7 
70 
7. 
CY1 body 
16.0 
16.0 
50 
8. 
CY2 body 
15.1 
15.1 
50 
9. 
CY3 body 
17.4 
17.2 
50 
10.  PCB near BR1 
19.0 
18.9 
70 
11.  C1 body near BR1 
25.5 
25.6 
50 
12.  PCB between Q6 & Q7 
41.2 
42.5 
70 
13.  T2 coil 
52.6 
51.9 
65 
14.  T2 core 
49.5 
49.0 
65 
15.  CT1 coil 
51.6 
52.6 
65 
16.  DT1 coil 
36.8 
37.5 
65 
17.  DT1 core 
32.7 
33.2 
65 
18.  T1 coil 
46.3 
48.0 
65 
19.  T1 core 
47.4 
49.5 
65 
20.  CY4 body 
40.2 
41.2 
50 
21.  U2 body 
42.8 
44.1 
65 
22.  PCB naer U1 
42.1 
44.3 
70 
23.  L2 coil 
23.6 
25.0 
70 
24.  PCB near IC1 
26.6 
26.8 
70 
25.  L1 coil 
29.9 
30.0 
70 
26.  C17 body 
26.2 
26.5 
70 
27.  Plastic enclosure inside near T2 
18.1 
18.4 
-- 
28.  Wooden enclosure inside near T2 
7.1 
7.4 
60 
29.  Metal enclosure outside near power 
13.1 
13.5 
40 
 
 
 
 
 
Winding temperature rise measurements 
 
 
Ambient temperature t1 (
o
C)  ................................
19.3 
— 
 
Ambient temperature t2 (
o
C)  ................................
19.6 
— 