TP10110019-ST
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IECEN60065G
7.1
TABLE: temperature rise measurements
P
Power consumption in the OFF/Stand-by
OFF: 0 W
Position of the functional switch (W) ......................ON: 31.4 W (108 V)
31.5 W (132 V)
—
Operating conditions
Test voltage: 120 x 0.9 = 108 Vac; 120 V x 1.1 = 132 Vac (T2, UST-FOR-YOU / F02801610)
Un (Vac)
In (A)
Pn (W)
Pout (W)
108
0.592
31.4
132
0.525
31.5
Monitored point:
dT (K)
Limit dT (K)
Input voltage
108 Vac
132 Vac
--
1.
CN1 body
24.6
24.0
50
2.
PCB nera TH1
28.8
27.5
70
3.
CX1 body
25.7
24.8
65
4.
CX2 body
25.5
24.5
65
5.
LF1 coil
26.3
25.1
70
6.
LF2 coil
25.8
24.6
70
7.
CY1 body
22.3
21.9
50
8.
CY2 body
20.2
19.9
50
9.
CY3 body
24.4
23.8
50
10. PCB near BR1
27.6
26.8
70
11. C1 body near BR1
35.8
34.8
50
12. PCB between Q6 & Q7
54.1
51.1
70
13. T2 coil
59.7
58.5
65
14. T2 core
64.2
52.9
65
15. CT1 coil
62.2
61.1
65
16. DT1 coil
46.0
45.2
65
17. DT1 core
41.9
41.4
65
18. T1 coil
56.8
57.8
65
19. T1 core
53.6
54.1
65
20. CY4 body
48.9
48.4
50
21. U2 body
49.3
49.1
65
22. PCB naer U1
50.1
48.3
70
23. L2 coil
29.6
30.6
70
24. PCB near IC1
32.7
32.8
70
25. L1 coil
33.0
32.9
70
26. C17 body
32.7
32.5
70
27. Plastic enclosure inside near T2
26.3
26.2
--
28. Wooden enclosure inside near T2
9.3
9.9
60
29. Metal enclosure outside near power
13.8
14.0
40
Winding temperature rise measurements
Ambient temperature t1 (
o
C) ................................
22.3
—
Ambient temperature t2 (
o
C) ................................
21.5
—
Page 58 of 75
TP10110019-ST
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IECEN60065G
7.1
TABLE: temperature rise measurements
P
Power consumption in the OFF/Stand-by
OFF: 0 W
Position of the functional switch (W) ......................ON: 31.9 W (198 V)
31.9 W (253 V)
—
Operating conditions
Test voltage: 220 x 0.9 = 198 Vac; 230 V x 1.1 = 253 Vac (T2, UST-FOR-YOU / F02801610)
Un (Vac)
In (A)
Pn (W)
Pout (W)
198
0.349
31.9
253
0.296
31.9
Monitored point:
dT (K)
Limit dT (K)
Input voltage
198 Vac
253 Vac
--
1.
CN1 body
20.7
21.2
50
2.
PCB nera TH1
18.9
19.3
70
3.
CX1 body
19.6
20.2
65
4.
CX2 body
19.8
20.1
65
5.
LF1 coil
21.0
21.3
70
6.
LF2 coil
20.1
20.9
70
7.
CY1 body
17.8
18.2
50
8.
CY2 body
16.8
17.3
50
9.
CY3 body
19.7
20.0
50
10. PCB near BR1
21.0
21.4
70
11. C1 body near BR1
28.9
29.7
50
12. PCB between Q6 & Q7
39.2
42.2
70
13. T2 coil
50.9
52.2
65
14. T2 core
50.2
51.2
65
15. CT1 coil
49.5
51.9
65
16. DT1 coil
38.0
40.2
65
17. DT1 core
37.6
39.6
65
18. T1 coil
49.7
54.8
65
19. T1 core
48.5
53.1
65
20. CY4 body
43.7
46.1
50
21. U2 body
43.2
45.8
65
22. PCB naer U1
40.0
43.4
70
23. L2 coil
27.4
30.2
70
24. PCB near IC1
27.0
27.8
70
25. L1 coil
32.3
33.4
70
26. C17 body
27.2
28.5
70
27. Plastic enclosure inside near T2
19.7
20.7
--
28. Wooden enclosure inside near T2
6.7
6.9
60
29. Metal enclosure outside near power
12.4
12.6
40
Winding temperature rise measurements
Ambient temperature t1 (
o
C) ................................
23.2
—
Ambient temperature t2 (
o
C) ................................
23.2
—
Page 59 of 75
TP10110019-ST
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IECEN60065G
7.1
TABLE: temperature rise measurements
P
Power consumption in the OFF/Stand-by
OFF: 0 W
Position of the functional switch (W) ......................ON: 25.8 W (108 V)
25.9 W (132 V)
—
Operating conditions
Test voltage: 120 x 0.9 = 108 Vac; 120 V x 1.1 = 132 Vac (T2, EASE HOUSE LIMITED / NT1810NL)
Un (Vac)
In (A)
Pn (W)
Pout (W)
108
0.441
25.8
132
0.39
25.9
Monitored point:
dT (K)
Limit dT (K)
Input voltage
108 Vac
132 Vac
--
1.
CN1 body
19.7
19.8
50
2.
PCB nera TH1
25.3
24.5
70
3.
CX1 body
17.9
17.9
65
4.
CX2 body
18.3
18.2
65
5.
LF1 coil
20.2
19.8
70
6.
LF2 coil
18.0
17.8
70
7.
CY1 body
16.3
16.5
50
8.
CY2 body
15.3
15.6
50
9.
CY3 body
17.6
17.8
50
10. PCB near BR1
19.3
19.4
70
11. C1 body near BR1
26.7
26.9
50
12. PCB between Q6 & Q7
42.8
43.2
70
13. T2 coil
52.6
52.6
65
14. T2 core
49.7
49.7
65
15. CT1 coil
52.4
53.4
65
16. DT1 coil
37.5
38.2
65
17. DT1 core
33.2
33.9
65
18. T1 coil
47.4
50.3
65
19. T1 core
48.7
52.2
65
20. CY4 body
41.0
42.2
50
21. U2 body
43.7
45.5
65
22. PCB naer U1
43.5
45.7
70
23. L2 coil
24.1
25.6
70
24. PCB near IC1
26.5
27.0
70
25. L1 coil
30.0
30.5
70
26. C17 body
26.5
27.1
70
27. Plastic enclosure inside near T2
18.4
18.9
--
28. Wooden enclosure inside near T2
6.6
7.2
60
29. Metal enclosure outside near power
13.1
13.7
40
Winding temperature rise measurements
Ambient temperature t1 (
o
C) ................................
19.0
—
Ambient temperature t2 (
o
C) ................................
18.7
—
Page 60 of 75
TP10110019-ST
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IECEN60065G
7.1
TABLE: temperature rise measurements
P
Power consumption in the OFF/Stand-by
OFF: 0 W
Position of the functional switch (W) ......................ON: 25.3 W (198 V)
25.8 W (253 V)
—
Operating conditions
Test voltage: 220 x 0.9 = 198 Vac; 230 V x 1.1 = 253 Vac (T2, EASE HOUSE LIMITED / NT1810NL)
Un (Vac)
In (A)
Pn (W)
Pout (W)
198
0.284
25.3
253
0.243
25.8
Monitored point:
dT (K)
Limit dT (K)
Input voltage
198 Vac
253 Vac
--
1.
CN1 body
18.6
18.4
50
2.
PCB nera TH1
21.6
21.0
70
3.
CX1 body
16.9
16.9
65
4.
CX2 body
17.2
17.0
65
5.
LF1 coil
18.5
18.3
70
6.
LF2 coil
16.9
16.7
70
7.
CY1 body
16.0
16.0
50
8.
CY2 body
15.1
15.1
50
9.
CY3 body
17.4
17.2
50
10. PCB near BR1
19.0
18.9
70
11. C1 body near BR1
25.5
25.6
50
12. PCB between Q6 & Q7
41.2
42.5
70
13. T2 coil
52.6
51.9
65
14. T2 core
49.5
49.0
65
15. CT1 coil
51.6
52.6
65
16. DT1 coil
36.8
37.5
65
17. DT1 core
32.7
33.2
65
18. T1 coil
46.3
48.0
65
19. T1 core
47.4
49.5
65
20. CY4 body
40.2
41.2
50
21. U2 body
42.8
44.1
65
22. PCB naer U1
42.1
44.3
70
23. L2 coil
23.6
25.0
70
24. PCB near IC1
26.6
26.8
70
25. L1 coil
29.9
30.0
70
26. C17 body
26.2
26.5
70
27. Plastic enclosure inside near T2
18.1
18.4
--
28. Wooden enclosure inside near T2
7.1
7.4
60
29. Metal enclosure outside near power
13.1
13.5
40
Winding temperature rise measurements
Ambient temperature t1 (
o
C) ................................
19.3
—
Ambient temperature t2 (
o
C) ................................
19.6
—
Click on the first or last page to see other SUB 140P service manuals if exist.