TP10110019-ST  
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No.: IECEN60065G 
 
 
 
(cont.) 
If this insulation forms part of a semiconductor 
component (e.g. an optocoupler), there is no 
distance through insulation requirement for the 
insulation consisting of an insulating compound 
completely filling the casing, so that 
CLEARANCES and 
CREEPAGE DISTANCES do not exist, if the 
component passes the electric strength test in the 
accordance with the compliance clause below 
and in addition: 
-
 
passes the test and inspection criteria of 13.6 
with an electric strength test of 10.3 using the 
test voltage of 1,5 kV multiplied by 1,6, and 
-
 
is subject to routine testing for electric 
strength during manufacturing, using a test 
voltage of 1,5 kV (for performance of the test 
see N.2.1). 
It is permitted to bridge this insulation with a 
capacitor complying with IEC 60384-14:1993, 
subclass Y2. 
A capacitor classified Y3 according to IEC 60384-
14:1993, may bridge this insulation under the 
following conditions: 
-
 
the insulation requirements are satisfied by 
having a capacitor classified Y3 as defined by 
IEC 60384-14, which in addition to the Y3 
testing, is tested with an Impulse test of 2.5 
kV defined in IEC 62151, subclause 6.2.1; 
-
 
the additional testing shall be performed on 
all the test specimens as described in IEC 
60384-14; 
-
 
the Impulse test of 2.5 kV is to be performed 
before the Endurance Test in IEC 60384-14 
in the sequence of tests as described in IEC 
60384-14. 
Subclause 5.3.2 (Corrigendum 1): 
Add after the fourth dash: 
NOTE - In Sweden, exclusions are applicable for 
equipment which is intended for connection to the 
building installation wiring using screw terminals 
or other reliable means, and for equipment which 
is intended for connection to the building 
installation wiring via an industrial plug and 
socket -outlet or an appliance coupler, or both, 
complying with IEC 60309 or with a comparable 
national standard. 
 
N/A 
 
 
 
 
Page 50 of 75 
 
TP10110019-ST  
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No.: IECEN60065G 
 
 
 
Annex ZC (informative)
 
A-deviations 
A-deviation: A national deviation due to regulations, the alteration of which 
 at least for the time being 
 
outside the competence of the CEN/CENELEC member. 
5.1 
Italy 
The following requirements shall be fulfilled: 
- The power consumption in Watts (W) shall be 
indicated on TV receivers and in their instruction 
for use (Measurement according to EN 60555-2). 
NOTE EN 60555-2 has since been replaced by 
IEC 60107-1:1997. 
- TV receivers shall be provided with an 
instruction for use, schematic diagrams and 
adjustments procedure in Italian language. 
- Marking for controls and terminals shall be in 
Italian language. Abbreviation and international 
symbols are allowed provided that they are 
explained in the instruction for use. 
- The ECC manufacturers are bound to issue a 
conformity declaration according to the above 
requirements in the instruction manual. The 
correct statement for conformity to be written in 
the instruction manual, shall be: 
Questo apparecchio è fabbricato nella CEE nel 
rispetto delle disposizioni del D.M. marzo 1992 ed 
è in particolare conforme alle prescrizioni dell'art. 
1 dello stesso D.M. 
- The first importers of TV receivers manufactured 
outside EEC are bound to submit the TV 
receivers for previous conformity certification to 
the Italian Post Ministry (PP.TT). 
The TV receivers shall have on the backcover the 
certification number in the following form: 
D.M. 26/03/1992 xxxxx/xxxxx/S or T or pT 
S for stereo 
T for teletext 
pT for retrofitable teletext 
Justification: 
Ministerial Decree of 26 March 1992: National 
rules for television receivers trade. 
NOTE The ministerial decree above contains 
additional, but not safety relevant requirements. 
 
N/A 
 
 
 
 
Page 51 of 75 
 
TP10110019-ST  
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No.: IECEN60065G 
 
 
 
6.1 
Germany 
The following requirement applies: 
For the operation of any cathode ray tube 
intended for the display of visual images 
operating at an acceleration voltage exceeding 
40 kV, authorization is required, or application of 
type approval (Bauartzulassung) and marking. 
Justification
NOTE Contact address: 
Physikalisch-Technische Bundesanstalt, 
Bundesallee 100, D-38116 Braunschweig, 
Tel.: Int+49-531-592-6320, Internet: 
http://www.ptb.de 
 
N/A 
14 
Sweden 
The following is added: 
Switches containing mercury such as 
thermostats, relays and level controllers are not 
allowed. 
Justification: 
Ordinance (1990:944) on Prohibition in 
Connection with Handling, Importation and 
Exportation of Chemical Products (Certain 
Cases). 
 
N/A 
 
 
 
 
Page 52 of 75 
 
TP10110019-ST  
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No.: IECEN60065G 
 
 
 
Supplement requirements for Subwoofer according to Amendment A11: 2008 of EN60065: 2002 
 
2.2 
Types of apparatus 
 
 
2.2.Z1 
Portable Sound System 
 
N/A 
 
Small battery powered audio equipment whose 
prime purpose is to listen to recorded or 
broadcasted sound 
 
N/A 
 
Audio equipment uses headphones or earphones 
that can be worn in or on or around the eats  
No such devices are provided 
N/A 
 
Audio equipment allows the user to walk around 
 
N/A 
 
MARKING AND INSTRUCTIONS 
 
 
5.4.1 za) 
Instructions for excessive sound pressure 
 
N/A 
 
HAZARDOUS RADIATIONS 
 
6.1 
Ionizing radiation 
N/A 
 
Apparatus shall be so constructed that personal 
protection against ionizing radiation is provided 
under normal and fault operation conditions 
No such device is provided 
N/A 
 
The dose-rate < 1 
µ
Sv/h (0.1 mR/h) 
 
N/A 
 
Z1 
Resistance to candle flame ignition 
 
 
Television set shall be designed that the likelihood 
of ignition and the spread of fire caused by a 
candle flame is reduced  
No such device is provided 
N/A 
 
 
 