JBL SUB 140P EMC - CB Certificate ▷ View online
Page 53 of 75
TP10110019-ST
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IECEN60065G
Supplement requirements for Subwoofer according to Amendment A2: 2010 of IEC60065: 2001 + A1:
2005
2005
7
HEATING UNDER NORMAL OPERATING CONDITIONS
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
(see appended table 7.1)
P
9
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS
9.1.1
For PROFESSIONAL EQUIPMENT, audio output
TERMINALS are permitted to be ACCESSIBLE to
SKILLED PERSONS if the audio output voltage,
when the apparatus is producing its NON-
CLIPPED OUTPUT POWER, is not greater than
120 V r.m.s.
TERMINALS are permitted to be ACCESSIBLE to
SKILLED PERSONS if the audio output voltage,
when the apparatus is producing its NON-
CLIPPED OUTPUT POWER, is not greater than
120 V r.m.s.
No such voltage
N/A
9.1.6
An instrument having an input impedance
consisting of a resistance of 100 M
consisting of a resistance of 100 M
Ω
± 5 M
Ω
in
parallel with an input capacitance of 25 pF or
less.
less.
N/A
9.2
No hazard after removing a cover by hand
No such part
N/A
11
FAULT CONDITIONS
11.2.1
Measurement of temperature rises
(see appended table 11.2)
P
11.2.3
Temperature rise of parts, other than windings and
PRINTED BOARDS, providing electrical insulation
PRINTED BOARDS, providing electrical insulation
(see appended table 11.2)
P
11.2.6
PRINTED BOARDS
N/A
Temperature rise of printed circuit boards (PCB)
exceeding the limits of table 3 by max. 100 K for
max. 5 min
exceeding the limits of table 3 by max. 100 K for
max. 5 min
N/A
a) Temperature rise of printed circuit boards (PCB)
to 20.1.3, exceeding the limits of table 3 by not
more than 100 K for an area not greater than
2 cm²
to 20.1.3, exceeding the limits of table 3 by not
more than 100 K for an area not greater than
2 cm²
N/A
b) Temperature rise of printed circuit boards (PCB)
to 20.1.3 up to 300 K for an area not greater than
2 cm² for a maximum of 5 min
to 20.1.3 up to 300 K for an area not greater than
2 cm² for a maximum of 5 min
N/A
Meets all the special conditions if conductors on
printed circuit boards are interrupted
printed circuit boards are interrupted
N/A
Class I protective earthing maintained
Class II apparatus
N/A
11.2.7
Temperature rise of parts not subject to the limits
of 11.2.1 to 11.2.5
of 11.2.1 to 11.2.5
(see appended table 11.2)
P
Page 54 of 75
TP10110019-ST
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IECEN60065G
12
MECHANICAL STRENGTH
12.1.3
Impact hammer test
P
Steel ball test
P
12.1.4
Drop test for portable apparatus where mass < 7
kg
kg
Measured: 10.1 Kg
N/A
12.1.5
Thermoplastic enclosures stress relief test
N/A
13
CLEARANCES AND CREEPAGE DISTANCES
13.2
Determination of working voltage
No such voltage
N/A
13.3.2
Circuits conductively connected to the mains
comply with table 8 and, where applicable, table 9
comply with table 8 and, where applicable, table 9
P
13.3.3
Circuits not conductively connected to the mains
comply with table 10
comply with table 10
N/A
13.6
For transformers, magnetic couplers and similar
devices, if insulation is relied upon for safety, a
voltage of 500 V r.m.s. at a frequency of 50 Hz or
60 Hz is applied between windings, and also
between windings and other conductive parts,
during the thermal cycling condition above.
devices, if insulation is relied upon for safety, a
voltage of 500 V r.m.s. at a frequency of 50 Hz or
60 Hz is applied between windings, and also
between windings and other conductive parts,
during the thermal cycling condition above.
N/A
14
COMPONENTS
14.5.3
PTC-S thermistors comply with IEC 60730-1:2007 No such device
N/A
14.11
Circuits conductively connected to the mains
comply with table 8 and, where applicable, table 9
comply with table 8 and, where applicable, table 9
P
14.11
Optocouplers
P
a) the TYPE TESTS and inspection criteria of
13.6; and ROUTINE TESTS for dielectric strength
during manufacturing, per Subclause N.2.1 using
the appropriate value of the test voltage in 10.3.2
applied for 1 s; or
13.6; and ROUTINE TESTS for dielectric strength
during manufacturing, per Subclause N.2.1 using
the appropriate value of the test voltage in 10.3.2
applied for 1 s; or
N/A
b) complies with the requirements of IEC 60747-
5-5, where the test voltages are as specified in
5.2.6 of IEC 60747-5-5:2007:
5-5, where the test voltages are as specified in
5.2.6 of IEC 60747-5-5:2007:
– the voltage Vini,a for TYPE TESTING; and
– the voltage Vini,b for ROUTINE TESTING,
applied for 1 s
applied for 1 s
shall be the appropriate value of the test voltage
in 10.3.2 of this standard.
in 10.3.2 of this standard.
P
Page 55 of 75
TP10110019-ST
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IECEN60065G
As an alternative to a) and b) above, it is
permitted to treat an optocoupler according to
13.8
permitted to treat an optocoupler according to
13.8
N/A
15
Terminals
15.1.2
Connectors for antenna, earth, audio, video or data:
No risk of insertion in mains socket-outlets
N/A
Not apply to connectors forming part of a non-
detachable cord which are not CONDUCTIVELY
CONNECTED TO THE MAINS, unless
ACCESSIBLE conductive parts become
HAZARDOUS LIVE during or after insertion of the
connector into the MAINS socket-outlet.
detachable cord which are not CONDUCTIVELY
CONNECTED TO THE MAINS, unless
ACCESSIBLE conductive parts become
HAZARDOUS LIVE during or after insertion of the
connector into the MAINS socket-outlet.
N/A
18
MECHANICAL STRENGTH OF PICTURE TUBES AND PROTECTION AGAINST
THE EFFECTS OF IMPLOSION s
THE EFFECTS OF IMPLOSION s
Picture tube separately approved to IEC 61965….: No such picture tube
N/A
Picture tube separately approved to 18.1............... :
N/A
18.1
Picture tubes > 16 cm intrinsically protected
N/A
IEC 61965 for intrinsically protected tubes,
including those having integral protective screens
including those having integral protective screens
N/A
18.2 for apparatus having non-intrinsically
protected tubes.
protected tubes.
N/A
18.2
Non-intrinsically protected picture tubes
N/A
19
STABILITY AND MECHANICAL HAZARDS
19.1
Test on a plane, inclined at 10
o
to the horizontal
P
19.2
100 N force applied vertically downwards
P
19.3
100 N force, or 13 % of weight, applied horizontally
to point of least stability
to point of least stability
N/A
19.4
Edges or corners not hazardous
N/A
19.5
Glass surfaces with an area exceeding 0,1 m² or
maximum dimension > 450 mm, pass the test of
19.5.1
maximum dimension > 450 mm, pass the test of
19.5.1
N/A
20
RESISTANCE TO FIRE
20.1.3
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage
between 50 V and 400 V (peak) a.c. or d.c. meets
V-1 or better to IEC 60707, unless used in a fire
enclosure
available power exceeds 15 W at a voltage
between 50 V and 400 V (peak) a.c. or d.c. meets
V-1 or better to IEC 60707, unless used in a fire
enclosure
The PCB has the flammability
rating of V-0
rating of V-0
P
Page 56 of 75
TP10110019-ST
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IECEN60065G
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage >
400 V (peak) a.c. or d.c. meets V-0 to IEC 60695-
11-10
available power exceeds 15 W at a voltage >
400 V (peak) a.c. or d.c. meets V-0 to IEC 60695-
11-10
N/A
20.1.4
Components and parts not covered by 20.1.1,
20.1.2 and 20.1.3 (other than fire enclosures)
mounted nearer to a potential ignition source than
the distances in Table 21 comply with the relevant
flammability category in IEC 69695-11-10 as
specified in Table 21
20.1.2 and 20.1.3 (other than fire enclosures)
mounted nearer to a potential ignition source than
the distances in Table 21 comply with the relevant
flammability category in IEC 69695-11-10 as
specified in Table 21
The bobbin of transformer (T1
and T2) has the flammability
rating of V-0
and T2) has the flammability
rating of V-0
P
Components and parts as above but shielded from
a potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
a potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
No such barrier
N/A