Page 53 of 75 
 
TP10110019-ST  
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No.: IECEN60065G 
 
 
 
Supplement requirements for Subwoofer according to Amendment A2: 2010 of IEC60065: 2001 + A1: 
2005 
 
HEATING UNDER NORMAL OPERATING CONDITIONS 
 
7.1.5 
Parts not subject to a limit under 7.1.1 to 7.1.4 
(see appended table 7.1) 
 
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS 
 
9.1.1 
For PROFESSIONAL EQUIPMENT, audio output 
TERMINALS are permitted to be ACCESSIBLE to 
SKILLED PERSONS if the audio output voltage, 
when the apparatus is producing its NON-
CLIPPED OUTPUT POWER, is not greater than 
120 V r.m.s. 
No such voltage 
N/A 
9.1.6 
An instrument having an input impedance 
consisting of a resistance of 100 M
 ± 5 M
 in 
parallel with an input capacitance of 25 pF or 
less. 
 
N/A 
9.2 
No hazard after removing a cover by hand 
No such part 
N/A 
 
11 
FAULT CONDITIONS 
 
11.2.1 
Measurement of temperature rises 
(see appended table 11.2) 
11.2.3 
Temperature rise of parts, other than windings and 
PRINTED BOARDS, providing electrical insulation 
(see appended table 11.2) 
11.2.6 
PRINTED BOARDS 
 
N/A 
 
Temperature rise of printed circuit boards (PCB) 
exceeding the limits of table 3 by max. 100 K for 
max. 5 min 
 
N/A 
 
a) Temperature rise of printed circuit boards (PCB) 
to 20.1.3, exceeding the limits of table 3 by not 
more than 100 K for an area not greater than 
2 cm² 
 
N/A 
 
b) Temperature rise of printed circuit boards (PCB) 
to 20.1.3 up to 300 K for an area not greater than 
2 cm² for a maximum of 5 min 
 
N/A 
 
Meets all the special conditions if conductors on 
printed circuit boards are interrupted 
 
N/A 
 
Class I protective earthing maintained 
Class II apparatus 
N/A 
11.2.7 
Temperature rise of parts not subject to the limits 
of 11.2.1 to 11.2.5 
(see appended table 11.2) 
 
 
 
 
 
Page 54 of 75 
 
TP10110019-ST  
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No.: IECEN60065G 
 
 
 
12 
MECHANICAL STRENGTH 
 
12.1.3 
Impact hammer test 
 
 
Steel ball test 
 
12.1.4 
Drop test for portable apparatus where mass < 7 
kg 
Measured: 10.1 Kg 
N/A 
12.1.5 
Thermoplastic enclosures stress relief test 
 
N/A 
 
13 
CLEARANCES AND CREEPAGE DISTANCES 
 
13.2 
Determination of working voltage 
No such voltage 
N/A 
13.3.2 
Circuits conductively connected to the mains 
comply with table 8 and, where applicable, table 9 
 
13.3.3 
Circuits not conductively connected to the mains 
comply with table 10 
 
N/A 
13.6 
For transformers, magnetic couplers and similar 
devices, if insulation is relied upon for safety, a 
voltage of 500 V r.m.s. at a frequency of 50 Hz or 
60 Hz is applied between windings, and also 
between windings and other conductive parts, 
during the thermal cycling condition above. 
 
N/A 
 
14 
COMPONENTS 
 
14.5.3 
PTC-S thermistors comply with IEC 60730-1:2007  No such device 
N/A 
14.11 
Circuits conductively connected to the mains 
comply with table 8 and, where applicable, table 9 
 
14.11 
Optocouplers 
 
 
 
 
a) the TYPE TESTS and inspection criteria of 
13.6; and ROUTINE TESTS for dielectric strength 
during manufacturing, per Subclause N.2.1 using 
the appropriate value of the test voltage in 10.3.2 
applied for 1 s; or 
 
N/A 
 
b) complies with the requirements of IEC 60747-
5-5, where the test voltages are as specified in 
5.2.6 of IEC 60747-5-5:2007: 
– the voltage Vini,a for TYPE TESTING; and 
– the voltage Vini,b for ROUTINE TESTING, 
applied for 1 s 
shall be the appropriate value of the test voltage 
in 10.3.2 of this standard. 
 
 
 
 
 
Page 55 of 75 
 
TP10110019-ST  
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No.: IECEN60065G 
 
 
 
 
As an alternative to a) and b) above, it is 
permitted to treat an optocoupler according to 
13.8 
 
N/A 
 
15 
Terminals 
 
15.1.2 
Connectors for antenna, earth, audio, video or data: 
 
 
No risk of insertion in mains socket-outlets 
 
N/A 
 
Not apply to connectors forming part of a non-
detachable cord which are not CONDUCTIVELY 
CONNECTED TO THE MAINS, unless 
ACCESSIBLE conductive parts become 
HAZARDOUS LIVE during or after insertion of the 
connector into the MAINS socket-outlet. 
 
N/A 
 
18 
MECHANICAL STRENGTH OF PICTURE TUBES AND PROTECTION AGAINST 
THE EFFECTS OF IMPLOSION s 
 
 
Picture tube separately approved to IEC 61965….:  No such picture tube 
N/A 
 
Picture tube separately approved to 18.1............... :   
N/A 
18.1 
Picture tubes > 16 cm intrinsically protected 
 
N/A 
 
IEC 61965 for intrinsically protected tubes, 
including those having integral protective screens 
 
N/A 
 
18.2 for apparatus having non-intrinsically 
protected tubes. 
 
N/A 
18.2 
Non-intrinsically protected picture tubes 
 
N/A 
 
19 
STABILITY AND MECHANICAL HAZARDS 
 
19.1 
Test on a plane, inclined at 10
o
 to the horizontal 
 
19.2 
100 N force applied vertically downwards 
 
19.3 
100 N force, or 13 % of weight, applied horizontally 
to point of least stability 
 
N/A 
19.4 
Edges or corners not hazardous 
 
N/A 
19.5 
Glass surfaces with an area exceeding 0,1 m² or 
maximum dimension > 450 mm, pass the test of 
19.5.1 
 
N/A 
 
20 
RESISTANCE TO FIRE 
 
20.1.3 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage 
between 50 V and 400 V (peak) a.c. or d.c. meets 
V-1 or better to IEC 60707, unless used in a fire 
enclosure 
The PCB has the flammability 
rating of V-0 
 
 
 
 
Page 56 of 75 
 
TP10110019-ST  
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No.: IECEN60065G 
 
 
 
 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage > 
400 V (peak) a.c. or d.c. meets V-0 to IEC 60695-
11-10 
 
N/A 
20.1.4 
Components and parts not covered by 20.1.1, 
20.1.2 and 20.1.3 (other than fire enclosures) 
mounted nearer to a potential ignition source than 
the distances in Table 21 comply with the relevant 
flammability category in IEC 69695-11-10 as 
specified in Table 21 
The bobbin of transformer (T1 
and T2) has the flammability 
rating of V-0 
 
Components and parts as above but shielded from 
a potential ignition source, with the barrier area in 
accordance with Table 21 and fig. 13 
No such barrier 
N/A 
 
Page of 87