JBL SUB 140P EMC - CB Certificate ▷ View online
Page 41 of 75
TP10110019-ST
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IECEN60065G
Denmark
Appliances of Class I provided with socket-outlets
with earth contact or which are intended to be
used in locations where protection against
indirect contact is required according to the wiring
rules shall be provided with a plug in accordance
with the Heavy Current Regulations, Section 107-
2-D1 standard sheet DK 2-1a.
with earth contact or which are intended to be
used in locations where protection against
indirect contact is required according to the wiring
rules shall be provided with a plug in accordance
with the Heavy Current Regulations, Section 107-
2-D1 standard sheet DK 2-1a.
N/A
Denmark
To the second paragraph the following is added:
Socket outlets intended for providing power to
Class II apparatus with a rated current of 2,5 A
shall have the following dimensions:
Class II apparatus with a rated current of 2,5 A
shall have the following dimensions:
Dimensions in mm
Other dimensions shall be in compliance with the
Heavy Current Regulations, Section 107-2-D1,
Standard Sheet DKA 1-3 for portable socket
outlets. Shutters are not required.
Heavy Current Regulations, Section 107-2-D1,
Standard Sheet DKA 1-3 for portable socket
outlets. Shutters are not required.
N/A
Denmark
To the third paragraph the following is added:
Mains socket-outlets with earthing contact shall
be in compliance with Heavy Current Regulations
Section 107-2-D1, Standard sheet DK 1-3a, DK
1-5a or DK 1-7a
be in compliance with Heavy Current Regulations
Section 107-2-D1, Standard sheet DK 1-3a, DK
1-5a or DK 1-7a
Justification:
Heavy Current Regulations, Section 107.
N/A
Page 42 of 75
TP10110019-ST
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IECEN60065G
Ireland
Apparatus which is fitted with a flexible cable or
cord shall be provided with a plug in accordance
with Statutory Instrument 525: 1997, “13 A Plugs
and Conversion Adapters for Domestic Use
Regulations: 1997”.
cord shall be provided with a plug in accordance
with Statutory Instrument 525: 1997, “13 A Plugs
and Conversion Adapters for Domestic Use
Regulations: 1997”.
Justification:
SI 525: 1997
N/A
Norway
Mains socket-outlets mounted on Class II
apparatus shall comply with the specifications
given in CEE Publ. 7 as far as applicable, with the
following amendments:
apparatus shall comply with the specifications
given in CEE Publ. 7 as far as applicable, with the
following amendments:
§ 8 Dimensions
a 2,5 A 250 V two-pole socket-outlets for
electronic apparatus shall comply with the
enclosed Standard Sheet I.
electronic apparatus shall comply with the
enclosed Standard Sheet I.
STANDARD SHEET I
2,5 A/ 250 V SOCKET-OUTLET FOR ELECTRONIC
APPLIANCES OF CLASS II
APPLIANCES OF CLASS II
Dimensions in mm
Other dimensions according to CEE Publication 7 Standard
Sheet 1 “Portable Single-Way Socket-Outlets”
Sheet 1 “Portable Single-Way Socket-Outlets”
§ 24 Mechanical strength
a 2,5 A, 250 V socket-outlets for Class II
electronic apparatus are tested as specified in
12.1.3 of EN 60065. Also the protecting rim shall
be tested.
electronic apparatus are tested as specified in
12.1.3 of EN 60065. Also the protecting rim shall
be tested.
Justification:
Act of 24 May 1929 relating to supervision of
electrical installation (TEA 1929/FEL 1998).
electrical installation (TEA 1929/FEL 1998).
N/A
Page 43 of 75
TP10110019-ST
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IECEN60065G
United Kingdom
Apparatus which is fitted with a flexible cable or
cord and is designed to be connected to a mains
socket conforming to BS 1363 by means of that
flexible cable or cord and plug shall be fitted with
a “standard plug” in accordance with Statutory
Instrument 1768: 1994: The Plugs and Sockets
etc. (Safety) Regulations 1994, unless exempted
by those Regulations.
cord and is designed to be connected to a mains
socket conforming to BS 1363 by means of that
flexible cable or cord and plug shall be fitted with
a “standard plug” in accordance with Statutory
Instrument 1768: 1994: The Plugs and Sockets
etc. (Safety) Regulations 1994, unless exempted
by those Regulations.
NOTE “Standard plug” is defined in SI 1768:1994
and essentially means an approved plug
conforming to BS 1363 or an approved
conversion plug.
and essentially means an approved plug
conforming to BS 1363 or an approved
conversion plug.
Justification:
SI 1768: 1994
N/A
Norway
Method b) of 8.1 is not permitted. Double or
reinforced insulation is required between parts
connected to the mains and parts connected to
the public telecommunications network
reinforced insulation is required between parts
connected to the mains and parts connected to
the public telecommunications network
N/A
J.2
Norway
After Table J.1 the following is added:
In Norway, due to the IT power distribution
system used, the a.c. MAINS supply voltage is
considered to be equal to the line-to-line voltage,
and will remain 230 V in case of a single earth
fault.
system used, the a.c. MAINS supply voltage is
considered to be equal to the line-to-line voltage,
and will remain 230 V in case of a single earth
fault.
Justification:
Based on a use in Norway of an IT power
distribution system where the neutral is not
provided.
distribution system where the neutral is not
provided.
N/A
Page 44 of 75
TP10110019-ST
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IECEN60065G
Annex B
Finland
Replace NOTE 1 by
In the CENELEC countries listed in IEC 62151,
special national conditions apply.
special national conditions apply.
Add the following:
All subclauses given below are subclauses of IEC
62151:2000 (ref. Corrigendum 1 and 2 to IEC
62151).
62151:2000 (ref. Corrigendum 1 and 2 to IEC
62151).
Subclause 4.1.1 (Corrigendum 2):
Add after the first paragraph:
NOTE - In Finland, Class I equipment which is
intended for connection to the building installation
via a non-industrial plug or a non-industrial
appliance coupler, or both and in addition is
intended for connection to other equipment or a
network shall, if safety relies on connection to
protective earth or if surge suppressors are
connected between the network terminals and
ACCESSIBLE parts, have a marking stating that
the equipment must be connected to an earthed
mains socket -outlet.
intended for connection to the building installation
via a non-industrial plug or a non-industrial
appliance coupler, or both and in addition is
intended for connection to other equipment or a
network shall, if safety relies on connection to
protective earth or if surge suppressors are
connected between the network terminals and
ACCESSIBLE parts, have a marking stating that
the equipment must be connected to an earthed
mains socket -outlet.
The marking text shall be as follows:
“Laite on liitettava suojamaadoituskoskettimilla
varustettuun pistorasiaan”
“Laite on liitettava suojamaadoituskoskettimilla
varustettuun pistorasiaan”
Subclause 5.3.1 (Corrigendum 1):
Add after the first test specifications paragraph:
NOTE 1 In Finland, Norway and Sweden, there
are additional requirements for the insulation.
are additional requirements for the insulation.
Renumber the existing note as note 2.
For additional requirements for the insulation in
Sweden in the NOTE 1 the following text is added
between the first and second paragraph (this text
is identical to the text in EN 60950-1:2001):
Sweden in the NOTE 1 the following text is added
between the first and second paragraph (this text
is identical to the text in EN 60950-1:2001):
If this insulation is solid, including insulation
forming part of a component, it shall at least
consist of either
forming part of a component, it shall at least
consist of either
-
two layers of thin sheet material, each of
which shall pass the electric strength test
below, or
which shall pass the electric strength test
below, or
-
one layer having a distance through
insulation of at least 0,4 mm, which shall
pass the electric strength test below.
insulation of at least 0,4 mm, which shall
pass the electric strength test below.
N/A