JBL SUB 140P EMC - CB Certificate ▷ View online
Page 25 of 75
TP10110019-ST
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IECEN60065G
A
APPENDIX A, ADDITIONAL REQUIREMENTS FOR APPARATUS WITH
PROTECTION AGAINST SPLASHING WATER
PROTECTION AGAINST SPLASHING WATER
A.5.1
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not
apply
apply
N/A
A.10.2.1
Enclosure provides protection against splashing
water
water
N/A
A.10.2.2
Humidity treatment carried out for 7 days
N/A
B
APPENDIX B, APPARATUS TO BE CONNECTED TO THE
TELECOMMUNICATION NETWORKS
TELECOMMUNICATION NETWORKS
Complies with IEC 62151 clause 1
N/A
Complies with IEC 62151 clause 2
N/A
Complies with IEC 62151 clause 3 but with 3.5.4
modified to 2.4.10 of this standard
modified to 2.4.10 of this standard
N/A
Complies with IEC 62151 clause 4 but with 4.1.2,
4.1.3 and 4.2.1.2 modified in accordance with
annex B of this standard
4.1.3 and 4.2.1.2 modified in accordance with
annex B of this standard
N/A
Complies with IEC 62151 cause 5 but with 5.3.1
modified in accordance with annex B of this
standard
modified in accordance with annex B of this
standard
N/A
Complies with IEC 62151 clause 6
N/A
Complies with IEC 62151 clause 7
N/A
Complies with IEC 62151 annex A, B and C
N/A
L
APPENDIX L, ADDITIONAL REQUIREMENTS FOR ELECTRONIC FLASH
APPARATUS FOR PHOTOGRAPHIC PURPOSES
APPARATUS FOR PHOTOGRAPHIC PURPOSES
L5.4
Marking and Instructions
N/A
L9.1.1
Terminals to connection to synchroniser not
Hazardous Live
Hazardous Live
N/A
L7.1.5 &
L11.2.6
L11.2.6
Lithium batteries meet permissible temp rise in
Table 3 , unless comply with 6.3.2 of IEC 60086-4
Table 3 , unless comply with 6.3.2 of IEC 60086-4
N/A
L14.6.6
Mains switch characteristics appropriate to its
function under normal conditions
function under normal conditions
N/A
Page 26 of 75
TP10110019-ST
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IECEN60065G
IEC 60065, 7th ed. + A1
(EN 60065: 2002 + A1: 2006 + A11: 2008)
GROUP DIFFERENCES, NATIONAL DEVIATIONS AND SPECIAL NATIONAL CONDITIONS IN THE
CENELEC COUNTRIES
C = CENELEC COMMON MODIFICATIONS
S = SPECIAL NATIONAL CONDITIONS
A = A-DEVIATIONS (NATIONAL DEVIATIONS)
CONTENTS
C: Add the following annexes:
Annex ZB (normative) Special national conditions
Annex ZC (informative) A-deviations
Considered
P
2.2Z1
C: Add after the definition 2.2.12 the following
new definition:
PORTABLE SOUND SYSTEM
small battery powered audio equipment:
• whose prime purpose is to listen to recorded or
broadcasted sound; and
• that uses headphones or earphones that can be
worn in or on or around the ears; and
• that allows the user to walk around
NOTE Examples are mini-disk or CD players,
MP3 audio players or similar equipment
N/A
Page 27 of 75
TP10110019-ST
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IECEN60065G
3.1
C: Add the following indent at the end of the list:
- exposure to excessive sound pressures from
headphones or earphones.
headphones or earphones.
NOTE A new method of measurement is
described in EN 50332-1, Sound system
equipment: Headphones and earphones
associated with portable audio equipment
described in EN 50332-1, Sound system
equipment: Headphones and earphones
associated with portable audio equipment
−
Maximum sound pressure level measurement
methodology and limit considerations
methodology and limit considerations
−
Part 1:
General method for “one package equipment”,
and in EN 50332-2, Sound system equipment:
Headphones and earphones associated with
portable audio equipment
and in EN 50332-2, Sound system equipment:
Headphones and earphones associated with
portable audio equipment
−
Maximum sound
pressure level measurement methodology and
limit considerations
limit considerations
−
Part 2: Guidelines to
associate sets with headphones coming from
different manufacturers.
different manufacturers.
N/A
4.1.1
C: Replace the text of the note by:
NOTE For ROUTINE TEST reference is made to
EN 50333.
EN 50333.
P
5.1 i)
C: Replace the note by:
NOTE For RATED POWER CONSUMPTION
measurements of TVs reference is made to EN
62087. Measurements are done in the ON (play)
operating mode.
measurements of TVs reference is made to EN
62087. Measurements are done in the ON (play)
operating mode.
N/A
5.4.1
Add the following indent:
za) For a PORTABLE SOUND SYSTEM, a
warning that excessive sound pressure from
earphones and headphones can cause hearing
loss.
warning that excessive sound pressure from
earphones and headphones can cause hearing
loss.
N/A
Page 28 of 75
TP10110019-ST
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IECEN60065G
6.1
C: Replace the subclause by:
6.1 Ionizing radiation
Apparatus including a potential source of ionizing
radiation shall be so constructed that personal
protection against ionizing radiation is provided
under normal operating conditions and under
fault conditions.
Compliance is checked by measurement under
the following conditions:
In addition to the normal operating conditions, all
controls adjustable from the outside BY HAND,
by any object such as a tool or a coin, and those
internal adjustments or pre-sets which are not
locked in a reliable manner, are adjusted so as to
give maximum radiation whilst maintaining an
intelligible picture for 1 h, at the end of which the
measurement is made.
NOTE 1 Soldered joints and paint lockings are
examples of adequate locking.
The dose-rate is determined by means of a
radiation monitor with an effective area of 10 cm2
• at any point 10 em from the outer surface of the
apparatus.
Moreover, the measurement shall be made under
fault conditions causing an increase of the high-
voltage, provided an intelligible picture is
maintained for 1 h, at the end of which the
measurement is made.
The dose-rate shall not exceed 1/lSv/h (0,1 mRlh)
taking account of the background level.
NOTE 2 These values appear in Directive
96/29/Euratom of 13th May 1996.
A picture is considered to be intelligible if the
following conditions are met:
- a scanning amplitude of at least 70 %of the
usable screen width;
- a minimum luminance of 50 cti/m" with locked
blank raster provided by a test generator;
- a horizontal resolution corresponding to at least
1,5 MHz in the centre, with a similar vertical
degradation;
- not more than one flashover per 5 min.
1,5 MHz in the centre, with a similar vertical
degradation;
- not more than one flashover per 5 min.
N/A
Click on the first or last page to see other SUB 140P service manuals if exist.