DOWNLOAD JBL SUB 140P Service Manual ↓ Size: 2.06 MB | Pages: 87 in PDF or view online for FREE

Model
SUB 140P
Pages
87
Size
2.06 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
sub-140p.pdf
Date

JBL SUB 140P EMC - CB Certificate ▷ View online

 
 
 
 
Page 25 of 75 
 
TP10110019-ST  
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No.: IECEN60065G 
 
 
 
APPENDIX A, ADDITIONAL REQUIREMENTS FOR APPARATUS WITH 
PROTECTION AGAINST SPLASHING WATER 
 
A.5.1 
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not 
apply 
 
N/A 
A.10.2.1 
Enclosure provides protection against splashing 
water 
 
N/A 
A.10.2.2 
Humidity treatment carried out for 7 days 
 
N/A 
 
APPENDIX B, APPARATUS TO BE CONNECTED TO THE 
TELECOMMUNICATION NETWORKS 
 
 
Complies with IEC 62151 clause 1 
 
N/A 
 
Complies with IEC 62151 clause 2 
 
N/A 
 
Complies with IEC 62151 clause 3 but with 3.5.4 
modified to 2.4.10 of this standard 
 
N/A 
 
Complies with IEC 62151 clause 4 but with 4.1.2, 
4.1.3 and 4.2.1.2 modified in accordance with 
annex B of this standard 
 
N/A 
 
Complies with IEC 62151 cause 5 but with 5.3.1 
modified in accordance with annex B of this 
standard 
 
N/A 
 
Complies with IEC 62151 clause 6  
 
N/A 
 
Complies with IEC 62151 clause 7  
 
N/A 
 
Complies with IEC 62151 annex A, B and C 
 
N/A 
 
APPENDIX L, ADDITIONAL REQUIREMENTS FOR ELECTRONIC FLASH 
APPARATUS FOR PHOTOGRAPHIC PURPOSES 
 
L5.4 
Marking and Instructions 
 
N/A 
L9.1.1 
Terminals to connection to synchroniser not 
Hazardous Live 
 
N/A 
L7.1.5 & 
L11.2.6 
Lithium batteries meet permissible temp rise in 
Table 3 , unless comply with 6.3.2 of IEC 60086-4 
 
N/A 
L14.6.6 
Mains switch characteristics appropriate to its 
function under normal conditions 
 
N/A 
 
 
 
 
Page 26 of 75 
 
TP10110019-ST  
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No.: IECEN60065G 
 
 
 
 
IEC 60065, 7th ed. + A1 
(EN 60065: 2002 + A1: 2006 + A11: 2008) 
 
GROUP DIFFERENCES, NATIONAL DEVIATIONS AND SPECIAL NATIONAL CONDITIONS IN THE 
CENELEC COUNTRIES 
 
C = CENELEC COMMON MODIFICATIONS 
S = SPECIAL NATIONAL CONDITIONS 
A = A-DEVIATIONS (NATIONAL DEVIATIONS) 
 
 
CONTENTS 
C: Add the following annexes: 
Annex ZB (normative) Special national conditions 
Annex ZC (informative) A-deviations 
Considered 
2.2Z1 
C: Add after the definition 2.2.12 the following 
new definition: 
PORTABLE SOUND SYSTEM 
small battery powered audio equipment: 
• whose prime purpose is to listen to recorded or 
broadcasted sound; and 
• that uses headphones or earphones that can be 
worn in or on or around the ears; and 
• that allows the user to walk around 
NOTE Examples are mini-disk or CD players, 
MP3 audio players or similar equipment 
 
N/A 
 
 
 
 
Page 27 of 75 
 
TP10110019-ST  
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No.: IECEN60065G 
 
 
 
3.1 
C: Add the following indent at the end of the list: 
- exposure to excessive sound pressures from 
headphones or earphones. 
NOTE A new method of measurement is 
described in EN 50332-1, Sound system 
equipment: Headphones and earphones 
associated with portable audio equipment 
 
Maximum sound pressure level measurement 
methodology and limit considerations 
 Part 1: 
General method for “one package equipment”, 
and in EN 50332-2, Sound system equipment: 
Headphones and earphones associated with 
portable audio equipment 
 Maximum sound 
pressure level measurement methodology and 
limit considerations 
 Part 2: Guidelines to 
associate sets with headphones coming from 
different manufacturers. 
 
N/A 
4.1.1 
C: Replace the text of the note by: 
NOTE For ROUTINE TEST reference is made to 
EN 50333. 
 
5.1 i) 
C: Replace the note by: 
NOTE For RATED POWER CONSUMPTION 
measurements of TVs reference is made to EN 
62087. Measurements are done in the ON (play) 
operating mode. 
 
N/A 
5.4.1 
Add the following indent: 
za) For a PORTABLE SOUND SYSTEM, a 
warning that excessive sound pressure from 
earphones and headphones can cause hearing 
loss. 
 
N/A 
 
 
 
 
Page 28 of 75 
 
TP10110019-ST  
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No.: IECEN60065G 
 
 
 
6.1 
C: Replace the subclause by: 
6.1 Ionizing radiation 
Apparatus including a potential source of ionizing 
radiation shall be so constructed that personal 
protection against ionizing radiation is provided 
under normal operating conditions and under 
fault conditions. 
Compliance is checked by measurement under 
the following conditions: 
In addition to the normal operating conditions, all 
controls adjustable from the outside BY HAND, 
by any object such as a tool or coin, and those 
internal adjustments or pre-sets which are not 
locked in a reliable manner, are adjusted so as to 
give maximum radiation whilst maintaining an 
intelligible picture for h, at the end of which the 
measurement is made. 
NOTE 1 Soldered joints and paint lockings are 
examples of adequate locking. 
The dose-rate is determined by means of 
radiation monitor with an effective area of 10 cm2 
• at any point 10 em from the outer surface of the 
apparatus. 
Moreover, the measurement shall be made under 
fault conditions causing an increase of the high-
voltage, provided an intelligible picture is 
maintained for h, at the end of which the 
measurement is made. 
The dose-rate shall not exceed 1/lSv/h (0,mRlh) 
taking account of the background level. 
NOTE 2 These values appear in Directive 
96/29/Euratom of 13th May 1996. 
A picture is considered to be intelligible if the 
following conditions are met: 
- a scanning amplitude of at least 70 %of the 
usable screen width; 
- a minimum luminance of 50 cti/m" with locked 
blank raster provided by a test generator; 
- a horizontal resolution corresponding to at least 
1,5 MHz in the centre, with a similar vertical 
degradation;                                                           
- not more than one flashover per 5 min.
 
 
N/A 
Page of 87
Display

Click on the first or last page to see other SUB 140P service manuals if exist.