JBL SUB 140P EMC - CB Certificate ▷ View online
Page 5 of 75
TP10110019-ST
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IECEN60065G
Instructions for multimedia system connection
N/A
Special stability warning for fixed installation
N/A
Warning: battery exposure to heat
N/A
Warning: protective film on CRT face
N/A
5.4.2
Disconnect device: plug/coupler or all-pole mains
switch location, accessibility and markings
switch location, accessibility and markings
Attachment plug is used
P
Instructions for permanently connected equipment Not this type
N/A
6
HAZARDOUS RADIATIONS
6.1
Ionizing radiation < 36 pA/kg (0,5 mR/h)
No such device
N/A
6.1
EN 60065
EN 60065
N/A
6.2
Laser radiation, emission limits to IEC 60825-1 .... :
N/A
Emission limits under fault conditions .................... :
N/A
7
HEATING UNDER NORMAL OPERATING CONDITIONS
7.1
Temperature rises not exceeding specified values,
no operation of fuse links
no operation of fuse links
(see appended table 7.1)
P
7.1.1
Temperature rise of accessible parts
(see appended table 7.1)
P
7.1.2
Temperature rise of parts providing electrical
insulation
insulation
(see appended table 7.1)
P
7.1.3
Temperature rise of parts acting as a support or as
a mechanical barrier
a mechanical barrier
N/A
7.1.4
Temperature rise of windings
(see appended table 7.1)
P
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
(see appended table 7.1)
P
7.2
Softening temperature of insulating material
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
o
C
Recognized components are
provided
provided
N/A
Page 6 of 75
TP10110019-ST
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IECEN60065G
8
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION
AGAINST ELECTRIC SHOCK
AGAINST ELECTRIC SHOCK
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
untreated textile oxide films and beads etc.
considered to be bare
Windings are covered by
lacquer
lacquer
P
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
device, fuse-links or handling drawers etc.
No such components are
replaced by hand
replaced by hand
N/A
8.3
Insulation of hazardous live parts not provided by
hygroscopic material
hygroscopic material
No such hazardous live parts
N/A
8.4
No risk of electric shock following the removal of a
cover which can be removed by hand
cover which can be removed by hand
No such construction
N/A
8.5
Class I equipment
Basic insulation between hazardous live parts and
earthed accessible parts
earthed accessible parts
Class II apparatus
N/A
A resistor bridging basic insulation complying with
14.1 a)
14.1 a)
N/A
A capacitor bridging basic insulation complying
with 14.2.1 a)
with 14.2.1 a)
N/A
8.6
Class II equipment and Class II constructions within Class I equipment
Reinforced or double insulation between
hazardous live parts and accessible parts
hazardous live parts and accessible parts
P
Components bridging reinforced or double
insulation complying with 14.1 a) or 14.3
insulation complying with 14.1 a) or 14.3
Transformer (CT1, T1, DT1
and T2) complied with 14.3
and T2) complied with 14.3
P
Basic insulation bridged by components complying
with 14.3.4.3
with 14.3.4.3
N/A
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.2.1 a)
bridged by a capacitor complying with 14.2.1 a)
X-capacitor (CX1, CX2) and Y-
capacitor (CY1, CY2) are
provided
capacitor (CY1, CY2) are
provided
P
Reinforced or double insulation being bridged with
2 capacitors in series complying with 14.2.1 a)
2 capacitors in series complying with 14.2.1 a)
N/A
Reinforced or double insulation being bridged with
a single capacitor complying with 14.2.1 b)
a single capacitor complying with 14.2.1 b)
Y-capacitor (CY3, CY4) is
provided
provided
P
8.7
This clause is void
N/A
Page 7 of 75
TP10110019-ST
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IECEN60065G
8.8
Basic or supplementary insulation > 0,4 mm (mm)
................................................................................. :
Primary wires: min. 0.4 mm for
each layer
each layer
Bobbin of Transformer (DT1,
NT1670NL) between
primary/secondary winding and
core: 1.0 mm
NT1670NL) between
primary/secondary winding and
core: 1.0 mm
Bobbin of Transformer (T1,
NT1759NL) between
primary/secondary winding and
core: 0.71 mm
NT1759NL) between
primary/secondary winding and
core: 0.71 mm
Bobbin of Transformer (T2,
F02801610 and NT1810NL)
between primary/secondary
winding and core: 1.0 mm
F02801610 and NT1810NL)
between primary/secondary
winding and core: 1.0 mm
P
Reinforced insulation > 0,4 mm (mm) ................... : Optocoupler (U2) > 0.4 mm
P
Thin sheet insulation (excluding non-separable thin
sheet insulation. See 8.22)
sheet insulation. See 8.22)
3 layers tape of transformer
(DT1, NT1670NL; T2,
F02801610 and NT1810NL)
between primary winding and
secondary winding (RI)
(DT1, NT1670NL; T2,
F02801610 and NT1810NL)
between primary winding and
secondary winding (RI)
Triple insulation wire of
transformer (T1, NT1759NL)
between primary winding and
secondary winding (RI)
transformer (T1, NT1759NL)
between primary winding and
secondary winding (RI)
P
Basic or supplementary insulation, at least two
layers, each meeting 10.3
layers, each meeting 10.3
N/A
Basic or supplementary insulation, three layers
any two of which meet 10.3
any two of which meet 10.3
N/A
Reinforced insulation, two layers each of which
meet 10.3
meet 10.3
N/A
Reinforced insulation, three layers any two which
meet 10.3
meet 10.3
For Transformer (DT1,
NT1670NL; T2, F02801610
and NT1810NL) only
NT1670NL; T2, F02801610
and NT1810NL) only
P
8.9
Adequate insulation between internal hazardous
live conductors and accessible parts
live conductors and accessible parts
Measured min. 0.4 mm
P
Adequate insulation between internal hazardous
live parts and conductors connected to accessible
parts
live parts and conductors connected to accessible
parts
Measured min. 0.4 mm
P
8.10
Double insulation between conductors connected
to the mains and accessible parts.
Double insulation between internal hazardous live
parts and conductors connected to accessible
parts
to the mains and accessible parts.
Double insulation between internal hazardous live
parts and conductors connected to accessible
parts
P
8.11
Detaching of wires
Page 8 of 75
TP10110019-ST
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IECEN60065G
No undue reduction of creepages or clearance
distances if wires become detached
distances if wires become detached
All primary wires are fixed by
double secure method
double secure method
P
Vibration test carried out ........................................ : Comply with sub-clause 12.1.2
P
8.12
This clause is void
N/A
8.13
Adequate fastening of windows, lenses, lamp
covers etc. (pull test 20 N for 10 s)
covers etc. (pull test 20 N for 10 s)
No such device
N/A
8.14
Adequate fastening of covers (pull test 50 N for
10 s)
10 s)
N/A
8.15
No risk of damage to the insulation of internal
wiring due to hot parts or sharp edges
wiring due to hot parts or sharp edges
P
8.16
Only special supply equipment can be used
N/A
8.17
Insulated winding wire without additional
interleaved insulation
interleaved insulation
N/A
8.18
Endurance test as required by 8.17
N/A
8.19
Disconnection from the mains
8.19.1
Disconnect device
Appliance inlet is used
P
All-pole switch or circuit breaker with >3 mm
contact separation
contact separation
No such device
N/A
8.19.2
Mains switch ON indication
A lighted display during the
“ON” position is clearly
discernible and the word
“Power” is marked on the
mains switch
“ON” position is clearly
discernible and the word
“Power” is marked on the
mains switch
P
8.20
Switch not fitted in the mains cord
P
8.21
Bridging components comply with clause 14
No such component
N/A
8.22
Non-separable thin sheet material
No such material
N/A
9
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS
9.1
Testing on the outside
P
9.1.1
For voltages >1000 V ac or >1500 V dc complies
with clause 13.3.1 for basic insulation
with clause 13.3.1 for basic insulation
No such voltage
N/A
9.1.1.1
Touch current measured from terminal devices
using the network in annex D ................................. :
using the network in annex D ................................. :
Measured max. open circuit
voltage: 328 Vpeak
voltage: 328 Vpeak
U1: max. 0.328 Vpeak
U2: max. 0.276 Vpeak
P
Discharge not exceeding 45
µ
C
35.78
µ
C
P
Energy of discharge not exceeding 350 mJ
< 15 KV
N/A
9.1.1.2
Test with test finger and test probe
P