JBL SUB 140P EMC - CB Certificate ▷ View online

 
 
 
 
Page 5 of 75 
 
TP10110019-ST  
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No.: IECEN60065G 
 
 
 
 
Instructions for multimedia system connection 
 
N/A 
 
Special stability warning for fixed installation 
 
N/A 
 
Warning: battery exposure to heat 
 
N/A 
 
Warning: protective film on CRT face 
 
N/A 
5.4.2 
Disconnect device: plug/coupler or all-pole mains 
switch location, accessibility and markings 
Attachment plug is used 
 
Instructions for permanently connected equipment  Not this type 
N/A 
 
HAZARDOUS RADIATIONS 
 
6.1 
Ionizing radiation < 36 pA/kg (0,5 mR/h) 
No such device 
N/A 
6.1         
EN 60065 
 
N/A 
6.2 
Laser radiation, emission limits to IEC 60825-1 .... :   
N/A 
 
Emission limits under fault conditions .................... :   
N/A 
 
HEATING UNDER NORMAL OPERATING CONDITIONS 
 
7.1 
Temperature rises not exceeding specified values, 
no operation of fuse links 
(see appended table 7.1) 
7.1.1 
Temperature rise of accessible parts 
(see appended table 7.1) 
7.1.2 
Temperature rise of parts providing electrical 
insulation 
(see appended table 7.1) 
7.1.3 
Temperature rise of parts acting as a support or as 
a mechanical barrier 
 
N/A 
7.1.4 
Temperature rise of windings 
(see appended table 7.1) 
7.1.5 
Parts not subject to a limit under 7.1.1 to 7.1.4 
(see appended table 7.1) 
7.2 
Softening temperature of insulating material 
supporting parts conductively connected to the 
mains carrying a current > 0,2 A at least 150
 o
Recognized components are 
provided 
N/A 
 
 
 
 
Page 6 of 75 
 
TP10110019-ST  
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No.: IECEN60065G 
 
 
 
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION 
AGAINST ELECTRIC SHOCK 
 
8.1 
Conductive parts covered by lacquer, paper, 
untreated textile oxide films and beads etc. 
considered to be bare 
Windings are covered by 
lacquer 
8.2 
No shock hazard when changing voltage setting 
device, fuse-links or handling drawers etc. 
No such components are 
replaced by hand 
N/A 
8.3 
Insulation of hazardous live parts not provided by 
hygroscopic material 
No such hazardous live parts 
N/A 
8.4 
No risk of electric shock following the removal of a 
cover which can be removed by hand 
No such construction 
N/A 
8.5 
Class I equipment 
 
 
Basic insulation between hazardous live parts and 
earthed accessible parts 
Class II apparatus 
N/A 
 
A resistor bridging basic insulation complying with 
14.1 a) 
 
N/A 
 
A capacitor bridging basic insulation complying 
with 14.2.1 a) 
 
N/A 
8.6 
Class II equipment and Class II constructions within Class I equipment 
 
 
Reinforced or double insulation between 
hazardous live parts and accessible parts 
 
 
Components bridging reinforced or double 
insulation complying with 14.1 a) or 14.3 
Transformer (CT1, T1, DT1 
and T2) complied with 14.3 
 
Basic insulation bridged by components complying 
with 14.3.4.3 
 
N/A 
 
Basic and supplementary insulation each being 
bridged by a capacitor complying with 14.2.1 a) 
X-capacitor (CX1, CX2) and Y-
capacitor (CY1, CY2) are 
provided 
 
Reinforced or double insulation being bridged with 
2 capacitors in series complying with 14.2.1 a) 
 
N/A 
 
Reinforced or double insulation being bridged with 
a single capacitor complying with 14.2.1 b) 
Y-capacitor (CY3, CY4) is 
provided 
8.7 
This clause is void 
 
N/A 
 
 
 
 
Page 7 of 75 
 
TP10110019-ST  
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No.: IECEN60065G 
 
 
 
8.8 
Basic or supplementary insulation > 0,4 mm (mm) 
................................................................................. : 
Primary wires: min. 0.4 mm for 
each layer 
Bobbin of Transformer (DT1, 
NT1670NL) between 
primary/secondary winding and 
core: 1.0 mm 
Bobbin of Transformer (T1, 
NT1759NL) between 
primary/secondary winding and 
core: 0.71 mm 
Bobbin of Transformer (T2, 
F02801610 and NT1810NL) 
between primary/secondary 
winding and core: 1.0 mm 
 
Reinforced insulation > 0,4 mm (mm)  ................... :  Optocoupler (U2) > 0.4 mm 
 
Thin sheet insulation (excluding non-separable thin 
sheet insulation. See 8.22) 
3 layers tape of transformer 
(DT1, NT1670NL; T2, 
F02801610 and NT1810NL) 
between primary winding and 
secondary winding (RI) 
Triple insulation wire of 
transformer (T1, NT1759NL) 
between primary winding and 
secondary winding (RI) 
 
Basic or supplementary insulation, at least two 
layers, each meeting 10.3 
 
N/A 
 
Basic or supplementary insulation, three layers 
any two of which meet 10.3 
 
N/A 
 
Reinforced insulation, two layers each of which 
meet 10.3 
 
N/A 
 
Reinforced insulation, three layers any two which 
meet 10.3 
For Transformer (DT1, 
NT1670NL; T2, F02801610 
and NT1810NL) only 
8.9 
Adequate insulation between internal hazardous 
live conductors and accessible parts 
Measured min. 0.4 mm 
 
Adequate insulation between internal hazardous 
live parts and conductors connected to accessible 
parts 
Measured min. 0.4 mm 
8.10 
Double insulation between conductors connected 
to the mains and accessible parts.                
Double insulation between internal hazardous live 
parts and conductors connected to accessible 
parts 
 
8.11 
Detaching of wires 
 
 
 
 
 
Page 8 of 75 
 
TP10110019-ST  
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No.: IECEN60065G 
 
 
 
 
No undue reduction of creepages or clearance 
distances if wires become detached 
All primary wires are fixed by 
double secure method 
 
Vibration test carried out  ........................................ :  Comply with sub-clause 12.1.2 
8.12 
This clause is void 
 
N/A 
8.13 
Adequate fastening of windows, lenses, lamp 
covers etc. (pull test 20 N for 10 s) 
No such device 
N/A 
8.14 
Adequate fastening of covers (pull test 50 N for 
10 s) 
 
N/A 
8.15 
No risk of damage to the insulation of internal 
wiring due to hot parts or sharp edges 
 
8.16 
Only special supply equipment can be used 
 
N/A 
8.17 
Insulated winding wire without additional 
interleaved insulation 
 
N/A 
8.18 
Endurance test as required by 8.17 
 
N/A 
8.19 
Disconnection from the mains 
 
8.19.1 
Disconnect device 
Appliance inlet is used 
 
All-pole switch or circuit breaker with >3 mm 
contact separation 
No such device  
N/A 
8.19.2 
Mains switch ON indication 
A lighted display during the 
“ON” position is clearly 
discernible and the word 
“Power” is marked on the 
mains switch 
8.20 
Switch not fitted in the mains cord 
 
8.21 
Bridging components comply with clause 14 
No such component 
N/A 
8.22 
Non-separable thin sheet material 
No such material  
N/A 
 
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS 
 
9.1 
Testing on the outside 
9.1.1 
For voltages >1000 V ac or >1500 V dc complies 
with clause 13.3.1 for basic insulation  
No such voltage 
N/A 
9.1.1.1 
Touch current measured from terminal devices 
using the network in annex D ................................. : 
Measured max. open circuit 
voltage: 328 Vpeak  
U1: max. 0.328 Vpeak  
U2: max. 0.276 Vpeak 
 
Discharge not exceeding 45 
µ
35.78 
µ
 
Energy of discharge not exceeding 350 mJ 
< 15 KV 
N/A 
9.1.1.2 
Test with test finger and test probe 
 
Page of 87