JBL SUB 140P EMC - CB Certificate ▷ View online

 
 
 
 
Page 17 of 75 
 
TP10110019-ST  
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No.: IECEN60065G 
 
 
 
14.5.2.4 
Not possible to touch hazardous live parts when 
replacing fuse-links without the use of a tool ......... : 
The fuse is not replaceable by 
user 
N/A 
14.5.3 
PTC-S thermistors comply with IEC 60730-1 
No such device 
N/A 
 
PTC-S devices (15 W) category V-1 or better 
 
N/A 
14.5.4 
Circuit protectors have adequate breaking capacity 
and their position is correctly marked 
 
N/A 
14.6 
Switches 
 
14.6.1 a) 
Separate testing to IEC 61058 including: 
10 000 operations 
Normal pollution suitability 
Resistance to heat and fire level 3 
and 
V-0 compliance with annex G, G.1.1 
Approval switch is provided 
14.6.1 b) 
Tested in the apparatus: 
N/A 
 
Switch controlling > 0.2 A with open contact  
voltage > 35 V (peak)/24 V dc complying with 
14.6.3, 14.6.4 and V-0 in annex G, G.1.1 
 
N/A 
 
Switch controlling > 0.2 A with open contact  
voltage < 35 V (peak)/24 V dc complying with 
14.6.3 and V-0 in annex G, G.1.1 
 
N/A 
 
Switch controlling < 0.2 A with open contact  
voltage > 35 V (peak)/24 V dc complying with  
14.6.4 and V-0 in annex G, G.1.1 
 
N/A 
14.6.2 
Switch tested to 14.6.1 b) constructed to IEC 
61058-1 subclause 13.1 and has making/breaking  
action independent of speed of actuation 
 
N/A 
14.6.3 
Switch tested to 14.6.1 b) compliant with IEC 
61058-1 subclause 16.2.2 d) and m) not attaining 
excessive temperatures in use 
 
N/A 
14.6.4 
Switch tested to 14.6.1 b) has adequate dielectric 
strength 
 
N/A 
14.6.5 
Mains switch controlling mains socket outlets 
additional tests to IEC 61058-1 
 
N/A 
 
Socket outlet current marking correct 
 
N/A 
14.7 
Safety interlocks 
 
 
Safety interlocks to 2.8 of IEC 60950 
No such device 
N/A 
14.8 
Voltage setting devices 
 
 
Voltage setting device not likely to be changed 
accidentally 
No such device 
N/A 
 
 
 
 
Page 18 of 75 
 
TP10110019-ST  
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No.: IECEN60065G 
 
 
 
14.9 
Motors 
 
14.9.1 
Endurance test on motors 
No such device 
N/A 
 
Motor start test 
 
N/A 
 
Dielectric strength test 
 
N/A 
14.9.2 
Not adversely affected by oil or grease etc. 
 
N/A 
14.9.3 
Protection against moving parts 
 
N/A 
14.9.4 
Motors with phase-shifting capacitors, three-phase 
motors and series motors meet clause. B.8, B.9 
and B.10 of IEC 60950, Annex B 
 
N/A 
14.10 
Batteries 
 
14.10.1 
Batteries mounted with no risk of accumulation of 
flammable gases 
No such device 
N/A 
14.10.2 
No possibility of recharging non-rechargeable 
batteries 
 
N/A 
14.10.3 
Recharging currents and times within 
manufacturers limits 
 
N/A 
 
Lithium batteries discharge and reverse currents 
within the manufacturers limits 
No such device 
N/A 
14.10.4 
Battery mould stress relief 
 
N/A 
14.10.5 
Battery drop test 
 
N/A 
14.11 
Optocouplers 
 
 
Optocouplers comply with Cl. 8 
Approved optocoupler is used 
 
 
14.12 
Surge suppression varistors 
 
 
Comply with IEC 61051-2 
Approved varistor is used 
 
Not connected between mains and accessible 
parts except for earthed parts of permanently 
connected apparatus 
 
 
Complies with the current pulse, fire hazard and 
thermal stress requirements of 14.12 
 
N/A 
 
15 
TERMINALS 
 
15.1.1 
Mains plug, appliance inlet, interconnection 
couplers and mains socket-outlet meet the 
appropriate standard 
Appliance inlet is approved 
 
 
 
 
Page 19 of 75 
 
TP10110019-ST  
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No.: IECEN60065G 
 
 
 
 
Overloading of plugs or appliance inlets 
prevented if the apparatus has mains socket 
outlets 
No such outlet 
N/A 
 
Overloading of internal wiring prevented if the 
apparatus has mains socket outlets 
No such outlet 
N/A 
15.1.2 
Connectors for antenna, earth, audio, video or data: 
 
 
No risk of insertion in mains socket-outlets 
 
 
No risk of insertion into audio or video: outlets 
marked with the symbol of 5.2 
 
15.1.3 
Output terminals of a.c. adaptors or similar devices 
not compatible with household mains socket-
outlets 
 
N/A 
15.2 
Provision for protective earthing 
 
 
Accessible conductive parts of Class I equipment 
reliably connected to earth terminal, within 
equipment 
Class II apparatus 
N/A 
 
Protective earth conductors correctly coloured 
 
N/A 
 
Equipment with non-detachable mains cord 
provided with separate protective earth terminal 
near mains input 
Not this type 
N/A 
 
Protective earth terminal resistant to corrosion 
 
N/A 
 
Earth resistance  test: < 0,1 
 at 25 A ................... :   
N/A 
15.3 
Terminals for external flexible cords and for permanent connection to the 
mains supply
 
 
15.3.1 
Adequate terminals for connection of permanent 
wiring 
It is not a permanently 
connected apparatus 
N/A 
15.3.2 
Reliable connection of non-detachable cords: 
 
 
Not soldered to conductors of a printed circuit 
board 
 
N/A 
 
Adequate clearances and creepage distances 
between connections should a wire break away 
 
N/A 
 
Wire secured by additional means to the conductor   
N/A 
15.3.3 
Screws and nuts clamping conductors have 
adequate threads: ISO 261, ISO 262 or similar 
 
N/A 
15.3.4 
Soldered conductors wrapped around terminal 
prior to soldering or held in place by additional 
means 
 
N/A 
 
Clamping of conductor and insulation if not 
soldered or held by screws 
 
N/A 
 
 
 
 
Page 20 of 75 
 
TP10110019-ST  
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No.: IECEN60065G 
 
 
 
15.3.5 
Terminals allow connection of appropriate cross-
sectional area of conductors, for the rated current 
of the equipment 
 
N/A 
15.3.6 
Terminals to 15.3.3 have sizes required by 
table 16 
 
N/A 
15.3.7 
Terminals clamp conductors between metal and 
have adequate pressure 
 
N/A 
 
Terminals designed to avoid conductor slipping out 
when tightened or loosened 
 
N/A 
 
Terminals adequately fixed to avoid loosening 
when the clamping is tightened or loosened and 
stress on internal wiring is avoided 
 
N/A 
15.3.8 
Terminals carrying a current more than 0,2 A: 
contact pressure not transmitted by insulating 
material except ceramic 
 
N/A 
15.3.9 
Termination of non-detachable cords: wires 
terminated near to each other 
 
N/A 
 
Terminals located and shielded: test with 8 mm 
strand 
 
N/A 
15.4 
Devices forming a part of the mains plug 
 
15.4.1 
No undue strain on mains socket-outlets 
Not direct plug-in apparatus 
N/A 
15.4.2 
Device complies with standard for dimensions of 
mains plugs 
 
N/A 
15.4.3 
Device has adequate mechanical strength (tests a, 
b, c) 
 
N/A 
 
16 
EXTERNAL FLEXIBLE CORDS 
 
16.1 
Mains cords sheathed type, complying with 
IEC 60227 for PVC or IEC 60245 for synthetic 
rubber cords ............................................................ : 
Complied with IEC 60227 
 
Non-detachable cords for Class I have 
green/yellow core for protective earth 
Not this type product 
N/A 
16.2 
Mains cords conductors have adequate cross-
sectional area for rated current consumption of the 
equipment 
NISPT-2, 2
×
0.75mm
2
 
16.3 
a) Flexible cords not complying with 16.1, used for 
interconnections between separate units of 
equipment used in combination and carrying 
hazardous live voltages, have adequate dielectric 
strength 
 
N/A 