Report No.: 
11008507 001 
 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
 
 
 
3.3.4 
S (GB): The range of conductor sizes of flexible 
cords to be accepted by terminals for equipment 
with a
 RATED CURRENT
 of over 10 A up to and 
including 13 A is: 
- 1,25 mm
2
 to 1,5 mm
2
 nominal cross-sectional 
area. 
No power supply cord. 
N/A 
4.3.6 
S (GB): The torque test is performed using a 
socket outlet complying with BS 1363 and the 
plug part of
 DIRECT PLUG
-
IN EQUIPMENT
 shall be 
assessed to BS 1363: Part 1, 12.1, 12.2, 12.3, 
12.9, 12.11, 12.12, 12.16 and 12.17, except that 
the test of 12.17 is performed at not less than 
125 °C. 
Not direct plug-in equipment. 
N/A 
 
S (IE): 
DIRECT PLUG
-
IN EQUIPMENT
 is known as 
plug similar devices. Such devices shall comply 
with Statutory Instrument 526:1997 – National 
Standards Authority of Ireland (Section 28) 
(Electrical plugs, plug similar devices and sockets 
for domestic use) Regulations, 1997. 
Not direct plug-in equipment. 
N/A 
4.3.13.6 
C: Add the following note: 
NOTE  Attention is drawn to 1999/519/EC: Council 
Recommendation on the limitation of exposure of the general 
public to electromagnetic fields 0 Hz to 300 GHz. Standards 
taking into account this recommendation are currently under 
development. 
Added. 
N/A 
6.1.2.1 
S (FI, NO, SE): Add the following text between 
the first and second paragraph: 
If this insulation is solid, including insulation 
forming part of a component, it shall at least 
consist of either 
- two layers of thin sheet material, each of which 
shall pass the electric strength test below, or 
- one layer having a distance through insulation of 
at least 0,4 mm, which shall pass the electric 
strength test below. 
If this insulation forms part of a semiconductor 
component (e.g. an optocoupler), there is no 
distance through insulation requirement for the 
insulation consisting of an insulating compound 
completely filling the casing, so that 
CLEARANCES 
AND CREEPAGE DISTANCES
 do not exist, if the 
component passes the electric strength test in 
accordance with the compliance clause below 
and in addition 
- passes the tests and inspection criteria of 2.10.8 
with an electric strength test of 1,5 kV multiplied 
by 1,6 (the electric strength test of 2.10.7 shall be 
performed using 1,5 kV), and 
- is subject to 
ROUTINGE TESTING
 for electric 
No TNV. 
N/A 
 
 
 
 
Page 33 of 58 
 
Report No.: 
11008507 001 
 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
 
 
 
strength during manufacturing, using a test 
voltage of 1,5 kV. 
It is permitted to bridge this insulation with a 
capacitor complying with EN 132400:1994, 
subclass Y2. 
A capacitor classified Y3 according to 
EN 132400:1994, may bridge this insulation 
under the following conditions: 
- the insulation requirements are satisfied by 
having a capacitor classified Y3 as defined by 
EN 132400, which in addition to the Y3 testing, is 
tested with an impulse test of 2,5 kV defined in 
EN 60950:2000, 6.2.2.1; 
- the additional testing shall be performed on all 
the test specimens as described in EN 132400; 
- the impulse test of 2,5 kV is to be performed 
before the endurance test in EN 132400, in the 
sequence of tests as described in EN 132400. 
6.1.2.2 
S (FI, NO, SE): The exclusions are applicable for 
PERMANENTLY CONNECTED EQUIPMENT
 and
 
PLUGGABLE EQUIPMENT TYPE B
 and equipment 
intended to be used in a 
RESTRICTED ACCESS 
LOCATION
 where equipotential bonding has been 
applied, e.g. in a telecommunication centre, and 
which has provision for a permanently connected 
PROTECTIVE EARTHING CONDUCTOR 
and is provided 
with instructions for the installation of that 
conductor by a service person. 
No TNV. 
N/A 
7.1 
S (FI, NO, SE): Requirements according to this 
annex, 6.1.2.1 and 6.1.2.2 apply with the term 
TELECOMMUNICATION NETWORK
 in 6.1.2 being 
replaced by the term 
CABLE DISTRIBUTION SYSTEM
Not connect to cable 
distribution system. 
N/A 
G.2.1 
S (NO): Due to the IT power distribution system 
used (see annex V, Fig. V.7), the 
A
.
C
MAINS 
SUPPLY
 voltage is considered to be equal to the 
line-to-line voltage, and will remain at 230 V in 
case of a single earth fault. 
Class III equipment. 
N/A 
Annex H 
C: Replace the last paragraph of this annex by: 
At any point 10 cm from the surface of the 
operator access area, the dose rate shall not 
exceed 1 µSv/h (0,1 mR/h) (see note). Account is 
taken of the background level. 
Replace the notes as follows: 
NOTE  These values appear in Directive 96/29/Euratom. 
 
Delete Note 2. 
Replaced. 
N/A 
Annex P 
C: Replace the text of this annex by: 
See annex ZA. 
Replaced. 
N/A 
 
 
 
 
Page 34 of 58 
 
Report No.: 
11008507 001 
 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
 
 
 
Annex Q 
C: Replace the title of IEC 61032 by "Protection of persons and equipment by 
enclosures – Probes for verification". 
Add the following notes for the standards indicated: 
IEC 60127 
NOTE Harmonized as EN 60127 (Series) (not modified) 
IEC 60269-2-1 NOTE Harmonized as HD 630.2.1 S4:2000 (modified) 
IEC 60529 
NOTE Harmonized as EN 60529:1991 (not modified) 
IEC 61032 
NOTE Harmonized as EN 61032:1998 (not modified) 
IEC 61140 
NOTE Harmonized as EN 61140:2001 (not modified) 
ITU-T Recommendation K.31 
 
 
N/A 
 
 
 
 
Page 35 of 58 
 
Report No.: 
11008507 001 
 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
 
 
 
Annex ZA 
C: NORMATIVE REFERENCES TO INTERNATIONAL PUBLICATIONS WITH 
THEIR RELEVANT EUROPEAN PUBLICATIONS 
NOTE  When an international publication has been modified by common modifications, indicated by 
(mod), the relevant EN/HD applies. 
N/A 
 
 
IEC 60050-151 
 
 
 
IEC 60050-195 
 
 
EN 60065:1998 + corr. June 1999 
IEC 60065 (mod):1998 
 
 
EN 60073:1996 
IEC 60073:1996 
 
 
HD 566 S1:1990 
IEC 60085:1984 
 
 
HD 214 S2:1980 
IEC 60112:1979 
 
 
HD 611.4.1.S1:1992 
IEC 60216-4-1:1990 
 
 
HD 21 
1)
 Series 
IEC 60227 (mod) Series 
 
 
HD 22 
2)
 Series 
IEC 60245 (mod) Series 
 
 
EN 60309 Series 
IEC 60309 Series 
 
 
EN 60317-43:1997 
IEC 60317-43:1997 
 
 
EN 60320 Series 
IEC 60320 (mod) Series 
 
 
HD 384.3 S2:1995 
IEC 60364-3 (mod):1993 
 
 
HD 384.4.41 S2:1996 
IEC 60364-4-41 (mod):1992 
3)
 
 
 
EN 132400:1994 
4)
  
+ A2:1998 + A3:1998 + A4:2001 
IEC 60384-14:1993 
 
 
EN 60417-1 
IEC 60417-1 
 
 
HD 625.1 S1:1996 + corr. Nov. 1996 
IEC 60664-1 (mod):1992 
 
 
EN 60695-2-2:1994 
IEC 60695-2-2:1991 
 
 
EN 60695-2-11:2001 
IEC 60695-2-11:2000 
 
 
 
IEC 60695-2-20:1995 
 
 
 
IEC 60695-10-2:1995 
 
 
 
IEC 60695-11-3:2000 
 
 
 
IEC 60695-11-4:2000 
 
 
EN 60695-11-10:1999 
IEC 60695-11-10:1999 
 
 
EN 60695-11-20:1999 
IEC 60695-11-20:1999 
 
 
EN 60730-1:2000 
IEC 60730-1:1999 (mod) 
 
 
EN 60825-1:1994 + corr. Febr. 1995 + 
A11:1996 + corr. July 1997 
IEC 60825-1:1993 
 
 
EN 60825-2:2000 
IEC 60825-2:2000 
 
 
 
IEC 60825-9:1999 
 
 
EN 60851-3:1996 
IEC 60851-3:1996 
 
 
EN 60851-5:1996 
IEC 60825-5:1996 
 
 
EN 60851-6:1996 
IEC 60851-6:1996 
 
 
 
IEC 60885-1:1987 
 
 
EN 60990:1999 
IEC 60990:1999 
 
 
 
IEC 61058-1:2000 
 
 
EN 61965:2001 
IEC 61965:2000 
 
 
EN ISO 178:1996 
ISO 178:1993 
 
 
EN ISO 179 Series 
ISO 179 Series 
 
 
EN ISO 180:2000 
ISO 180:1993 
 
Page of 62