JBL SPOT (serv.man2) EMC - CB Certificate ▷ View online
Page 40 of 58
Report No.:
11008507 001
TRF No.:IECEN60950_1B
TRF originator: SGS Fimko
Note(s):
1) The temperatures were measured under worst case normal mode defined in 1.2.2.1 and as described in
1.6.2 at voltages as described above.
2) With maximum of 25°C ambient temperature specified the max. temperature is calculated as follows:
Surface of equipment which may be touched:
- plastic
- plastic
→
Tmax = 95°C
4.5.2
TABLE: ball pressure test of thermoplastic parts
N/A
allowed impression diameter (mm) .................. : ≤ 2 mm
Part
Test temperature
(°C)
Impression diameter
(mm)
Note(s):
4.6.1, 4.6.2 Table: enclosure openings
N/A
Location
Size (mm)
Comments
Note(s):
4.7
Table: resistance to fire
P
Part
Manufacturer of material
Type of material
Thickness
(mm)
Flammability
class
Note(s): No openings.
5.1.6
TABLE: touch current measurement
N/A
Condition
L→ terminal A
(mA)
N → terminal A
(mA)
Limit
(mA)
Comments
Note(s):
5.2
TABLE: electric strength tests and impulse tests
N/A
Test voltage applied between:
Test voltage (V)
Breakdown
Page 41 of 58
Report No.:
11008507 001
TRF No.:IECEN60950_1B
TRF originator: SGS Fimko
Note(s):
5.3
TABLE: fault condition tests
N/A
ambient temperature (°C) ...................................... :
model/type of power supply ................................... :
manufacturer of power supply ............................... :
rated markings of power supply ............................. :
No.
Component no.
Fault
Test
voltage (V)
Test
time
Fuse
no.
Fuse
current (A)
Result
Note(s):
Page 42 of 58
Report No.:
11008507 001
National Differences
Clause
Requirement − Test
Result – Remark
Verdict
Australian National Differences according to CB Bulletin No. 110A, June 2006
APPENDIX Australian National Differences according to CB Bulletin No. 110A, June 2006
(AS/NZS 60950.1:2003)
(IEC Publication 60950-1:2001)
P
EXPLANATION FOR ABBREVIATIONS
P=Pass, F=Fail, N/A=Not applicable. Placed in the column to the right.
Annex ZZ Variations
Between the definitions for "Person, service" and
"Range, rated frequency" insert the following:
"Range, rated frequency" insert the following:
1.2
Potential ignition source
1.2.12.201
Inserted.
N/A
1.2.12.15
After the definition of 1.2.12.15, add the following:
1.2.12.201 Potential ignition source:
Possible fault which can start a fire if the open-
circuit voltage measured across an interruption or
faulty contact exceeds a value of 50 V (peak) a.c.
or d.c. and the product of the peak value of this
voltage and the measured r.m.s. current under
normal operating conditions exceeds 15 VA.
circuit voltage measured across an interruption or
faulty contact exceeds a value of 50 V (peak) a.c.
or d.c. and the product of the peak value of this
voltage and the measured r.m.s. current under
normal operating conditions exceeds 15 VA.
Such a faulty contact or interruption in an
electrical connection includes those which may
occur in conductive patterns on printed boards.
electrical connection includes those which may
occur in conductive patterns on printed boards.
NOTE 201: An electronic protection circuit may be
used to prevent such a fault from becoming a
potential ignition source.
used to prevent such a fault from becoming a
potential ignition source.
NOTE 202: This definition is from AS/NZS
60065:2003.
60065:2003.
Added.
N/A
1.5.1
Add the following to the end of first paragraph:
"or the relevant Australian/New Zealand
Standard."
Standard."
Added.
P
1.5.2
Add the following to the end of first and third dash
items:
items:
"or the relevant Australian/New Zealand
Standard."
Standard."
Added.
P
2.1
Delete the Note.
Deleted.
N/A
3.2.3
Delete Note 2.
Deleted.
N/A
Modify Table 3B as follows:
Rated current of
equipment A
Nominal
cross-
sectional
area mm
2
AWG or kcmil
(cross-sectional
area in mm
2
)
see note 2
3.2.5
Over 0.2 up to
and including 3
and including 3
0.5
1)
18 [0.8]
Modified.
N/A
Page 43 of 58
Report No.:
11008507 001
National Differences
Clause
Requirement − Test
Result – Remark
Verdict
Australian National Differences according to CB Bulletin No. 110A, June 2006
Over 3 up to and
including 7.5
including 7.5
0.75
16 [1.3]
Over 7.5 up to
and including 10
and including 10
(0.75)
2)
1.00
16 [1.3]
Over 10 up to
and including 16
and including 16
(1.0)
3)
1.5
14 [2]
Replace footnote 1) with the following:
1)
This nominal cross-sectional area is only
allowed for Class II appliances if the length of the
power supply cord, measured between the point
where the cord, or cord guard, enters the
appliances, and the entry to the plug does not
exceed 2 m (0.5 mm² three-core supply flexible
cords are not permitted; see AS/NZS 3191).
power supply cord, measured between the point
where the cord, or cord guard, enters the
appliances, and the entry to the plug does not
exceed 2 m (0.5 mm² three-core supply flexible
cords are not permitted; see AS/NZS 3191).
Delete Note 1.
4.3.6
Replace paragraph three with:
Equipment with a plug portion, suitable for
insertion into a 10 A 3-pin flat-pin socket-outlet
complying with AS/NZS 3112, shall comply with
the requirements in AS/NZS 3112 for equipment
with integral pins for insertion into socket-outlets.
insertion into a 10 A 3-pin flat-pin socket-outlet
complying with AS/NZS 3112, shall comply with
the requirements in AS/NZS 3112 for equipment
with integral pins for insertion into socket-outlets.
Replaced.
N/A
4.3.13.5
Add the following to the end of the first paragraph:
", or AS/NZS 2211.1"
Added.
N/A
4.7
Add the following paragraph:
For alternative tests refer to clause 4.7.201.
See below.
N/A
4.7.201
Add the following after clause 4.7.3.6:
4.7.201 Resistance to fire - Alternative tests
Added.
However, equipment under
test and materials used in
compliance with requirements
of IEC 60950-1. Alternative
test methods were not
considered.
test and materials used in
compliance with requirements
of IEC 60950-1. Alternative
test methods were not
considered.
N/A
4.7.201.1
General
Parts of non-metallic material shall be resistant to
ignition and spread of fire.
ignition and spread of fire.
This requirement does not apply to decorative
trims, knobs and other parts unlikely to be ignited
or to propagate flames originating from inside the
apparatus, or the following:
trims, knobs and other parts unlikely to be ignited
or to propagate flames originating from inside the
apparatus, or the following:
(a) Components that are contained in an
enclosure having a flammability category of
FV-0 according to AS/NSZ 4695.707 and
having openings only for the connecting wires
filling the openings completely, and for the
FV-0 according to AS/NSZ 4695.707 and
having openings only for the connecting wires
filling the openings completely, and for the
Alternative test methods were
not considered.
not considered.
N/A