Report No.:
11008507 001
National Differences
Clause
Requirement − Test
Result – Remark
Verdict
US National Differences according to CB Bulletin No. 110A, June 2006
standard supply outlets, receptacles and medium-
base or smaller lampholders if the supply branch
circuit protection is not suitable.
base or smaller lampholders if the supply branch
circuit protection is not suitable.
Power distribution transformers distributing power
at 100 volts or more, and rated 10 kVA or more,
require transformer overcurrent protection.
at 100 volts or more, and rated 10 kVA or more,
require transformer overcurrent protection.
3.2
Wiring methods (terminals, leads, etc.) used for
the connection of the equipment to the mains
shall be in accordance with the NEC/CEC.
the connection of the equipment to the mains
shall be in accordance with the NEC/CEC.
No direct mains connection.
N/A
3.2.1
Power supply cords are required to have
attachment plugs rated not less than 125 percent
of the rated current of the equipment.
attachment plugs rated not less than 125 percent
of the rated current of the equipment.
No direct mains connection.
N/A
3.2.3
Permanent connection of equipment to the mains
supply by a power supply cord is not permitted,
except for certain equipment, such as ATMs.
supply by a power supply cord is not permitted,
except for certain equipment, such as ATMs.
No direct mains connection.
N/A
3.2.5
Power supply cords are required to be no longer
than 4.5 m in length.
than 4.5 m in length.
Flexible power supply cords are required to be
compatible with Article 400 of the NEC, and
Tables 11 and 12 of the CEC.
compatible with Article 400 of the NEC, and
Tables 11 and 12 of the CEC.
No direct mains connection.
N/A
3.2.9
Permanently connected equipment is required to
have a suitable wiring compartment and wire
bending space.
have a suitable wiring compartment and wire
bending space.
No direct mains connection.
N/A
3.3
Wiring terminals and associated spacings for field
wiring connections shall comply with CSA C22.2
No. 0.
wiring connections shall comply with CSA C22.2
No. 0.
No direct mains connection.
N/A
3.3.3
Wire binding screws are not permitted to attach
conductors larger than 10 AWG (5.3 mm²).
conductors larger than 10 AWG (5.3 mm²).
No direct mains connection.
N/A
3.3.4
Terminals for permanent wiring, including
protective earthing terminals, are required to be
suitable for U.S./Canadian wire gauge sizes, rated
125 percent of the equipment rating, and be
specially marked when specified (1.7.7).
protective earthing terminals, are required to be
suitable for U.S./Canadian wire gauge sizes, rated
125 percent of the equipment rating, and be
specially marked when specified (1.7.7).
No direct mains connection.
N/A
3.4.2
Motor control devices are required for cord-
connected equipment with a motor if the
equipment is rated more than 12A, or if the motor
has a nominal voltage rating greater than 120V,
or is rated more than 1/3 hp (locked rotor current
over 43 A)
connected equipment with a motor if the
equipment is rated more than 12A, or if the motor
has a nominal voltage rating greater than 120V,
or is rated more than 1/3 hp (locked rotor current
over 43 A)
No motor control devices.
N/A
3.4.8
Vertically-mounted disconnect switches and
circuit breakers are required to have the ”on”
position indicated by the handle in the up position.
circuit breakers are required to have the ”on”
position indicated by the handle in the up position.
No such switch provided.
N/A
Page 57 of 58
Report No.:
11008507 001
National Differences
Clause
Requirement − Test
Result – Remark
Verdict
US National Differences according to CB Bulletin No. 110A, June 2006
3.4.11
For computer room applications, equipment with
battery systems capable of supplying 750 VA for
five minutes are required to have a battery
disconnect means that may be connected to the
computer room remote power-off circuit.
battery systems capable of supplying 750 VA for
five minutes are required to have a battery
disconnect means that may be connected to the
computer room remote power-off circuit.
No battery.
N/A
4.3.12
The maximum quantify of flammable liquid stored
in equipment is required to comply with NFPA 30.
in equipment is required to comply with NFPA 30.
No flammable liquid.
N/A
4.3.13
Equipment with lasers is required to meet Code of
Federal Regulations 21 CFR 1040 (and the
Canadian Radiation Emitting Devices Act, REDR
C1370).
Federal Regulations 21 CFR 1040 (and the
Canadian Radiation Emitting Devices Act, REDR
C1370).
N/A
4.7
For computer room applications, automated
information storage systems with combustible
media greater than 27 cubic feet are required to
have a provision for connection of either
automatic sprinklers or a gaseous agent
extinguishing system with an extended discharge.
information storage systems with combustible
media greater than 27 cubic feet are required to
have a provision for connection of either
automatic sprinklers or a gaseous agent
extinguishing system with an extended discharge.
Not information storage
systems.
systems.
N/A
4.7.3.1
For computer room applications, enclosures with
combustible material measuring greater than 0.9
m² or a single dimension greater than 1.8 m are
required to have a flame spread rating of 50 or
less. For other applications, enclosures with the
same dimensions require a flame spread rating of
200 or less.
combustible material measuring greater than 0.9
m² or a single dimension greater than 1.8 m are
required to have a flame spread rating of 50 or
less. For other applications, enclosures with the
same dimensions require a flame spread rating of
200 or less.
Not information storage
systems.
systems.
N/A
Annex H
Equipment that produces ionizing radiation is
required to comply with the Code of Federal
Regulations, 21 CFR 1020 (and the Canadian
Radiation Emitting Devices Act, REDR C1370).
required to comply with the Code of Federal
Regulations, 21 CFR 1020 (and the Canadian
Radiation Emitting Devices Act, REDR C1370).
No ionizing radiation.
N/A
Other differences
1.5.1
Some components and materials associated with
the risk of fire, electric shock, or personal injury
are required to have component or material
ratings in accordance with the applicable national
(U.S. and Canadian) component or material
requirements. These components include:
the risk of fire, electric shock, or personal injury
are required to have component or material
ratings in accordance with the applicable national
(U.S. and Canadian) component or material
requirements. These components include:
attachment plugs, battery packs (rechargeable
type, used with transportable equipment), cathode
ray tubes, circuit breakers, communication circuit
accessories, connectors (used for current
interruption of non-LPS circuits), cord sets and
power supply cords, direct plug-in equipment,
enclosures (outdoor), flexible cords and cables,
fuses (branch circuit), fuseholders, ground-fault
current interrupters, industrial control equipment,
insulating tape, interconnecting cables,
lampholders, limit controls, printed wiring,
protectors for communications circuits,
receptacles, solid state controls, supplementary
protectors, surge suppressors, switches
type, used with transportable equipment), cathode
ray tubes, circuit breakers, communication circuit
accessories, connectors (used for current
interruption of non-LPS circuits), cord sets and
power supply cords, direct plug-in equipment,
enclosures (outdoor), flexible cords and cables,
fuses (branch circuit), fuseholders, ground-fault
current interrupters, industrial control equipment,
insulating tape, interconnecting cables,
lampholders, limit controls, printed wiring,
protectors for communications circuits,
receptacles, solid state controls, supplementary
protectors, surge suppressors, switches
Components are approved,
see component list 1.5.1.
see component list 1.5.1.
P
Page 58 of 58
Report No.:
11008507 001
National Differences
Clause
Requirement − Test
Result – Remark
Verdict
US National Differences according to CB Bulletin No. 110A, June 2006
(including interlock switches), thermal cut-offs,
thermostats, multi-layer transformer winding wire,
tubing, wire connectors, and wire and cables.
thermostats, multi-layer transformer winding wire,
tubing, wire connectors, and wire and cables.
2.3.1
For TNV-2 and TNV-3 circuits with other than
ringing signals and with voltages exceeding
42.4 Vpeak or 60 Vd.c., the maximum acceptable
current through a 2000 ohm resistor (or greater)
connected across the voltage source with other
loads disconnected is 7.1 mA peak or 30 mA d.c.
under normal operating conditions.
ringing signals and with voltages exceeding
42.4 Vpeak or 60 Vd.c., the maximum acceptable
current through a 2000 ohm resistor (or greater)
connected across the voltage source with other
loads disconnected is 7.1 mA peak or 30 mA d.c.
under normal operating conditions.
No TNV.
N/A
2.3.2
In the event of a single fault, the limits of 2.2.3
apply to SELV Circuits and accessible conductive
parts.
apply to SELV Circuits and accessible conductive
parts.
No TNV.
N/A
2.6.3.3
When subject to impedance testing, protective
earthing and bonding are required to be subjected
to the additional test conditions specified.
earthing and bonding are required to be subjected
to the additional test conditions specified.
No direct mains connection.
N/A
3.2.1.2
Equipment connected to a centralized d.c. power
system, and having one pole of the DC mains
input terminal connected to the main protective
earthing terminal in the equipment, is required to
comply with special earthing, writing, marking and
installation instruction requirements.
system, and having one pole of the DC mains
input terminal connected to the main protective
earthing terminal in the equipment, is required to
comply with special earthing, writing, marking and
installation instruction requirements.
No direct mains connection.
N/A
4.2.8.1
Enclosures around CRTs with a face diameter of
160mm or more are required to reduce the risk of
injury due to the implosion of the CRT.
160mm or more are required to reduce the risk of
injury due to the implosion of the CRT.
No CRT.
N/A
4.3.2
Equipment with handles is required to comply with
special loading tests.
special loading tests.
No handles.
N/A
5.1.8.3
Equipment intended to receive telecommunication
ringing signals is required to comply with a special
touch current measurement tests.
ringing signals is required to comply with a special
touch current measurement tests.
N/A
6.2.1
Enamel coating on winding wire not considered
electrical separation unless subjected to special
investigation.
electrical separation unless subjected to special
investigation.
No used.
N/A
6.4
Equipment intended for connection to
telecommunication network outside plant cable is
required to be protected against overvoltage from
power line crosses in accordance with 6.4 and
Annex NAC.
telecommunication network outside plant cable is
required to be protected against overvoltage from
power line crosses in accordance with 6.4 and
Annex NAC.
N/A
6.5
Equipment connected to a telecommunications
network and supplied with an earphone intended
to be held against, or in the ear is required to
comply with special acoustic pressure tests.
network and supplied with an earphone intended
to be held against, or in the ear is required to
comply with special acoustic pressure tests.
N/A
M.2
Continuous ringing signals up to 16 mA only are
permitted if the equipment is subjected to special
installation and performance restrictions.
permitted if the equipment is subjected to special
installation and performance restrictions.
N/A
Page 1 of 5
Type Designation:
jbl spot (JBL)
Report Number:
11008507 001