Page 56 of 58 
 
Report No.: 
11008507 001 
National Differences 
Clause 
Requirement − Test 
Result – Remark 
Verdict 
 
US National Differences according to CB Bulletin No. 110A, June 2006 
standard supply outlets, receptacles and medium-
base or smaller lampholders if the supply branch 
circuit protection is not suitable. 
Power distribution transformers distributing power 
at 100 volts or more, and rated 10 kVA or more, 
require transformer overcurrent protection. 
3.2 
Wiring methods (terminals, leads, etc.) used for 
the connection of the equipment to the mains 
shall be in accordance with the NEC/CEC. 
No direct mains connection. 
N/A 
3.2.1 
Power supply cords are required to have 
attachment plugs rated not less than 125 percent 
of the rated current of the equipment. 
No direct mains connection. 
N/A 
3.2.3 
Permanent connection of equipment to the mains 
supply by a power supply cord is not permitted, 
except for certain equipment, such as ATMs. 
No direct mains connection. 
N/A 
3.2.5 
Power supply cords are required to be no longer 
than 4.5 m in length. 
Flexible power supply cords are required to be 
compatible with Article 400 of the NEC, and 
Tables 11 and 12 of the CEC. 
No direct mains connection. 
N/A 
3.2.9 
Permanently connected equipment is required to 
have a suitable wiring compartment and wire 
bending space. 
No direct mains connection. 
N/A 
3.3 
Wiring terminals and associated spacings for field 
wiring connections shall comply with CSA C22.2 
No. 0. 
No direct mains connection. 
N/A 
3.3.3 
Wire binding screws are not permitted to attach 
conductors larger than 10 AWG (5.3 mm²). 
No direct mains connection. 
N/A 
3.3.4 
Terminals for permanent wiring, including 
protective earthing terminals, are required to be 
suitable for U.S./Canadian wire gauge sizes, rated 
125 percent of the equipment rating, and be 
specially marked when specified (1.7.7). 
No direct mains connection. 
N/A 
3.4.2 
Motor control devices are required for cord-
connected equipment with a motor if the 
equipment is rated more than 12A, or if the motor 
has a nominal voltage rating greater than 120V, 
or is rated more than 1/3 hp (locked rotor current 
over 43 A) 
No motor control devices. 
N/A 
3.4.8 
Vertically-mounted disconnect switches and 
circuit breakers are required to have the ”on” 
position indicated by the handle in the up position. 
No such switch provided. 
N/A 
 
 
 
 
Page 57 of 58 
 
Report No.: 
11008507 001 
National Differences 
Clause 
Requirement − Test 
Result – Remark 
Verdict 
 
US National Differences according to CB Bulletin No. 110A, June 2006 
3.4.11 
For computer room applications, equipment with 
battery systems capable of supplying 750 VA for 
five minutes are required to have a battery 
disconnect means that may be connected to the 
computer room remote power-off circuit. 
No battery. 
N/A 
4.3.12 
The maximum quantify of flammable liquid stored 
in equipment is required to comply with NFPA 30. 
No flammable liquid. 
N/A 
4.3.13 
Equipment with lasers is required to meet Code of 
Federal Regulations 21 CFR 1040 (and the 
Canadian Radiation Emitting Devices Act, REDR 
C1370). 
 
N/A 
4.7 
For computer room applications, automated 
information storage systems with combustible 
media greater than 27 cubic feet are required to 
have a provision for connection of either 
automatic sprinklers or a gaseous agent 
extinguishing system with an extended discharge. 
Not information storage 
systems.  
N/A 
4.7.3.1 
For computer room applications, enclosures with 
combustible material measuring greater than 0.9 
m² or a single dimension greater than 1.8 m are 
required to have a flame spread rating of 50 or 
less. For other applications, enclosures with the 
same dimensions require a flame spread rating of 
200 or less. 
Not information storage 
systems. 
N/A 
Annex H 
Equipment that produces ionizing radiation is 
required to comply with the Code of Federal 
Regulations, 21 CFR 1020 (and the Canadian 
Radiation Emitting Devices Act, REDR C1370). 
No ionizing radiation. 
N/A 
Other differences 
1.5.1 
Some components and materials associated with 
the risk of fire, electric shock, or personal injury 
are required to have component or material 
ratings in accordance with the applicable national 
(U.S. and Canadian) component or material 
requirements. These components include: 
attachment plugs, battery packs (rechargeable 
type, used with transportable equipment), cathode 
ray tubes, circuit breakers, communication circuit 
accessories, connectors (used for current 
interruption of non-LPS circuits), cord sets and 
power supply cords, direct plug-in equipment, 
enclosures (outdoor), flexible cords and cables, 
fuses (branch circuit), fuseholders, ground-fault 
current interrupters, industrial control equipment, 
insulating tape, interconnecting cables, 
lampholders, limit controls, printed wiring, 
protectors for communications circuits, 
receptacles, solid state controls, supplementary 
protectors, surge suppressors, switches 
Components are approved, 
see component list 1.5.1. 
 
 
 
 
Page 58 of 58 
 
Report No.: 
11008507 001 
National Differences 
Clause 
Requirement − Test 
Result – Remark 
Verdict 
 
US National Differences according to CB Bulletin No. 110A, June 2006 
(including interlock switches), thermal cut-offs, 
thermostats, multi-layer  transformer winding wire, 
tubing, wire connectors, and wire and cables. 
2.3.1 
For TNV-2 and TNV-3 circuits with other than 
ringing signals and with voltages exceeding 
42.4 Vpeak or 60 Vd.c., the maximum acceptable 
current through a 2000 ohm resistor (or greater) 
connected across the voltage source with other 
loads disconnected is 7.1 mA peak or 30 mA d.c. 
under normal operating conditions. 
No TNV. 
N/A 
2.3.2  
In the event of a single fault, the limits of 2.2.3 
apply to SELV Circuits and accessible conductive 
parts. 
No TNV. 
N/A 
2.6.3.3 
When subject to impedance testing, protective 
earthing and bonding are required to be subjected 
to the additional test conditions specified. 
No direct mains connection. 
N/A 
3.2.1.2 
Equipment connected to a centralized d.c. power 
system, and having one pole of the DC mains 
input terminal connected to the main protective 
earthing terminal in the equipment, is required to 
comply with special earthing, writing, marking and 
installation instruction requirements. 
No direct mains connection. 
N/A 
4.2.8.1 
Enclosures around CRTs with a face diameter of 
160mm or more are required to reduce the risk of 
injury due to the implosion of the CRT. 
No CRT. 
N/A 
4.3.2 
Equipment with handles is required to comply with 
special loading tests. 
No handles. 
N/A 
5.1.8.3 
Equipment intended to receive telecommunication 
ringing signals is required to comply with a special 
touch current measurement tests. 
 
N/A 
6.2.1 
Enamel coating on winding wire not considered 
electrical separation unless subjected to special 
investigation. 
No used. 
N/A 
6.4 
Equipment intended for connection to 
telecommunication network outside plant cable is 
required to be protected against overvoltage from 
power line crosses in accordance with 6.4 and 
Annex NAC. 
 
N/A 
6.5 
Equipment connected to a telecommunications 
network and supplied with an earphone intended 
to be held against, or in the ear is required to 
comply with special acoustic pressure tests. 
 
N/A 
M.2 
Continuous ringing signals up to 16 mA only are 
permitted if the equipment is subjected to special 
installation and performance restrictions. 
 
N/A 
 
 