Page 28 of 58 
 
Report No.: 
11008507 001 
 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
 
 
 
2) it is adequately indicated on the X-ray emission 
source that 
i)  X-rays are generated and 
ii)  the electron acceleration voltage must not 
exceed the maximum value stipulated by 
the manufacturer or importer. 
c) A licence in accordance with Cl. 1 is also not 
required by persons who operate an X-ray 
emission source on which the electron 
acceleration voltage exceeds 20 kV if 
1) the X-ray emission source has been granted a 
type approval and 
2) it is adequately indicated on the X-ray emission 
source that 
i)  X-rays are generated 
ii) the device stipulated by the manufacturer or 
importer guarantees that the maximum 
permissible local dose rate in accordance 
with the type approval is not exceeded and 
iii) the electron acceleration voltage must not 
exceed the maximum value stipulated by the 
manufacturer or importer. 
d) Furthermore, a licence in accordance with 
Cl. 1 is also not required by persons who operate 
X-ray emission sources on which the electron 
acceleration voltage does not exceed 30 kV if 
1) the X-rays are generated only by intrinsically 
safe CRTs complying with Enclosure III, No. 6, 
2) the values stipulated in accordance with 
Enclosure III, No. 6.2 are limited by technical 
measures and specified in the device and 
3) it is adequately indicated on the X-ray emission 
source that the X-rays generated are ade-
quately screened by the intrinsically safe CRT. 
2.2.4 
S (NO): Requirements according to this annex, 
1.7.2 and 6.1.2.1 apply. 
No TNV. 
N/A 
2.3.2 
S (NO): Requirements according to this annex, 
6.1.2.1 apply. 
No TNV. 
N/A 
2.3.3 and 
2.3.4 
S (NO): Requirements according to this annex, 
1.7.2 and 6.1.2.1 apply. 
No TNV. 
N/A 
2.6.3.3 
S (GB): The current rating of the circuit shall be 
taken as 13 A, not 16 A. 
Class III equipment. 
N/A 
2.7.1 
C: Replace the subclause as follows: 
Basic requirements 
To protect against excessive current, short-
circuits and earth faults in 
PRIMARY CIRCUITS
protective devices shall be included either as 
Replaced. 
N/A 
 
 
 
 
Page 29 of 58 
 
Report No.: 
11008507 001 
 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
 
 
 
integral parts of the equipment or as parts of the 
building installation, subject to the following, a), b) 
and c): 
a) except as detailed in b) and c), protective 
devices necessary to comply with the 
requirements of 5.3 shall be included as parts of 
the equipment; 
b) for components in series with the mains input 
to the equipment such as the supply cord, 
appliance coupler, r.f.i. filter and switch, short-
circuit and earth fault protection may be provided 
by protective devices in the building installation; 
c) it is permitted for 
PLUGGABLE EQUIPMENT TYPE B
 
or 
PERMANENTLY CONNECTED EQUIPMENT
, to rely 
on dedicated overcurrent and short-circuit 
protection in the building installation, provided 
that the means of protection, e.g. fuses or circuit 
breakers, is fully specified in the installation 
instructions. 
If reliance is placed on protection in the building 
installation, the installation instructions shall so 
state, except that for 
PLUGGABLE EQUIPMENT TYPE 
A
 the building installation shall be regarded as 
providing protection in accordance with the rating 
of the wall socket outlet. 
 
S (GB): To protect against excessive currents 
and short-circuits in the 
PRIMARY CIRCUIT OF 
DIRECT PLUG
-
IN EQUIPMENT
, protective device shall 
be included as integral parts of the 
DIRECT PLUG
-
IN EQUIPMENT
Class III equipment. 
N/A 
2.7.2 
C: Void. 
Declared. 
N/A 
2.10.2 
C: Replace in the first line "(see also 1.4.7)" by 
"(see also 1.4.8)". 
Replaced. 
N/A 
2.10.3.1 
S (NO): Due to the IT power distribution system 
used (see annex V, Fig. V.7), the 
A
.
C
MAINS 
SUPPLY
 voltage is considered to be equal to the 
line-to-line voltage and will remain at 230 V in 
case of a single earth fault 
Class III equipment. 
N/A 
 
 
 
 
Page 30 of 58 
 
Report No.: 
11008507 001 
 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
 
 
 
3.2.1.1 
S (CH): Supply cords of equipment having a 
RATED CURRENT
 not exceeding 10 A shall be 
provided with a plug complying with SEV 1011 or 
IEC 60884-1 and one of the following dimension 
sheets: 
SEV 6532-2.1991, Plug type 15, 3P+N+PE   250/400 V, 10 A 
SEV 6533-2.1991, Plug type 11, L+N 
250 V, 10 A 
SEV 6534-2.1991, Plug type 12, L+N+PE 
250 V, 10 A 
In general, EN 60309 applies for plugs for 
currents exceeding 10 A. However, a 16 A plug 
and socket-outlet system is being introduced in 
Switzerland, the plugs of which are according to 
the following dimension sheets, published in 
February 1998: 
SEV 5932-2.1998, Plug type 25, 3L+N+PE   230/400 V, 16 A 
SEV 5933-2.1998, Plug type 21, L+N 
250 V, 16 A 
SEV 5934-2.1998, Plug type 23, L+N+PE 
250 V, 16 A
 
No power supply cord. 
N/A 
 
S (DK): Supply cords of single-phase equipment 
having a rated current not exceeding 13 A shall 
be provided with a plug according to the Heavy 
Current Regulations, Section 107-2-D1. 
CLASS I EQUIPMENT
 provided with socket-outlets 
with earth contacts or which are intended to be 
used in locations where protection against 
indirect contact is required according to the wiring 
rules shall be provided with a plug in accordance 
with standard sheet DK 2-1a or DK 2-5a. 
If ply-phase equipment and single-phase 
equipment having a 
RATED CURRENT
 exceeding 
13 A is provided with a supply cord with a plug, 
this plug shall be in accordance with the Heavy 
Current Regulations, Section 107-2-D1 or 
EN 60309-2. 
No power supply cord. 
N/A 
 
S (ES): Supply cords of single-phase equipment 
having a rated current not exceeding 10 A shall 
be provided with a plug according to 
UNE 20315:1994. 
Supply cords of single-phase equipment having a 
rated current not exceeding 2,5 A shall be 
provided with a plug according to 
UNE-EN 50075:1993. 
CLASS I EQUIPMENT
 provided with socket-outlets 
with earth contacts or which are intended to be 
used in locations where protection against 
indirect contact is required according to the wiring 
rules, shall be provided with a plug in accordance 
with standard UNE 20315:1994. 
If poly-phase equipment is provided with a supply 
cord with a plug, this plug shall be in accordance 
with UNE-EN 60309-2. 
No power supply cord. 
N/A 
 
 
 
 
Page 31 of 58 
 
Report No.: 
11008507 001 
 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
 
 
 
 
S (GB): Apparatus which is fitted with a flexible 
cable or cord and is designed to be connected to 
a mains socket conforming to BS 1363 by means 
of that flexible cable or cord and plug, shall be 
fitted with a 'standard plug' in accordance with 
Statutory Instrument 1768:1994 – The Plugs and 
Socket etc. (Safety) Regulations 1994, unless 
exempted by those regulations. 
NOTE – 'Standard plug' is defined in SI 1768:1994 and 
essentially means an approved plug conforming to BS 1363 
or an approved conversion plug. 
 
No power supply cord. 
N/A 
 
S (IE): Apparatus which is fitted with a flexible 
cable or cord and is designed to be connected to 
a mains socket conforming to I.S. 411 by means 
of that flexible cable or cord and plug, shall be 
fitted with a 13 A plug in accordance with 
Statutory Instrument 525:1997 – National 
Standards Authority of Ireland (section 28) (13 A 
Plugs and Conversion Adaptors for Domestic 
Use) Regulations 1997. 
No power supply cord. 
N/A 
3.2.3 
C: Delete Note 1 and in Table 3A, delete the 
conduit sizes in parentheses. 
Deleted. 
N/A 
3.2.5.1 
C: Replace 
"60245 IEC 53"  by  "H05 RR-F"; 
"60227 IEC 52"  by  "H03 VV-F or H03 VVH2-F"; 
"60227 IEC 53"  by  "H05 VV-F or H05 VVH2-F2". 
In Table 3B, replace the first four lines by the 
following: 
Up to and including 6  
 
0,75
1)
 
Over 6 up to and including 10  (0,75)
2) 
1,0 
Over 10 up to and including 16 (1,0)
3)
 
1,5 
In the Conditions applicable to Table 3B delete 
the words "in some countries" in condition 
1)
In Note 1, applicable to Table 3B, delete the 
second sentence. 
Replaced. 
N/A 
3.2.5.1 
S (GB): A power supply cord with conductor of 
1,25 mm
2
 is allowed for equipment with a rated 
current over 10 A and up to and including 13 A. 
No power supply cord. 
N/A 
3.3.4 
C: In table 3D, delete the fourth line: conductor 
sizes for 10 to 13 A, and replace with the 
following:
 
 
Deleted. 
N/A 
 
"Over 10 up to and including 16
 
1,5 to 2,5 
1,5 to 4" 
 
 
 
Delete the fifth line: conductor sizes for 13 to 
16 A. 
 
 
Page of 62