Report No.: 
11008507 001 
National Differences 
Clause 
Requirement − Test 
Result – Remark 
Verdict 
 
Australian National Differences according to CB Bulletin No. 110A, June 2006 
ventilation not exceeding 1 mm in width 
regardless of the length. 
(b)  The following parts which would contribute 
negligible fuel to a fire: 
small mechanical parts, the mass of which 
does not exceed 4 g, such as mounting 
parts, gears, cams, belts and bearings; 
small electrical components, such as 
capacitors with a volume not exceeding 
1750 mm
3
, integrated circuits, transistors and 
optocoupler packages, if these components 
are mounted on material flammability 
category FV-1 or better according to AS/NZS 
4695.707 
NOTE - In considering how to minimize 
propagation of fire and what “small parts” are, 
account should be taken of the cumulative effect 
of small parts adjacent to each other for the 
possible effect of propagating fire from one part to 
another. 
Compliance is checked by tests of 4.7.201.2, 
4.7.201.3, 4.7.201.4 and 4.7.201.5. 
For the base materials of printed boards, 
compliance is checked by the test of 4.7.201.5. 
The tests shall be carried out on parts of non-
metallic material, which have been removed from 
the apparatus. When the glow-wire test is carried 
out, the parts shall be placed in the same 
orientation, as they would be in normal use. 
These tests are not carried out on internal wiring. 
4.7.201.2 
Parts of non-metallic material are subjected to 
glow wire test of AS/NZS 4695.2.11, which is 
carried out at 550 °C. 
Parts for which the glow-wire test cannot be 
carried out, such as those made of soft or foamy 
material, shall meet the requirements specified in 
ISO 9772 for category FH-3 material. The glow-
wire test shall be not carried out on parts of 
materials classified at least FH-3 according to 
ISO 9772 provided that the sample was not 
thicker than the relevant part. 
Alternative test methods were 
not considered. 
N/A 
4.7.201.3 
Testing of insulating materials 
Parts of insulating materials supporting potential 
ignition sources shall be subject to the glow-wire 
test of AN/NZS 4695.2.11, which is carried out at 
750 °C. 
The test shall be also carried out on other parts of 
Alternative test methods were 
not considered. 
N/A 
 
 
 
 
Page 45 of 58 
 
Report No.: 
11008507 001 
National Differences 
Clause 
Requirement − Test 
Result – Remark 
Verdict 
 
Australian National Differences according to CB Bulletin No. 110A, June 2006 
insulating material which are within a distance of 
3 mm of the connection. 
NOTE - Contacts in components such as switch 
contacts are considered to be connections. 
For parts, which withstand the glow-wire test but 
produce a flame, other parts above the 
connection within the envelope of a vertical 
cylinder having a diameter of 20 mm and a height 
of 50 mm shall be subjected to the needle-flame 
test. However, parts shielded by a barrier which 
meets the needle-flame test shall not be tested. 
The needle-flame test shall be made in 
accordance with AS/NZS 4695.2.2 with the 
following modifications: 
5 Severities 
Replace with: 
The duration of application of the test flame shall 
be 30 s ± 1 s. 
 
8 Test procedure 
8.2 Modification: 
Replace the first sentence with: 
The specimen shall be arranged so that the flame 
can be applied to a vertical or horizontal edge as 
shown in the examples of figure 1. 
8.4 Modification: 
The first paragraph does not apply. 
Addition: 
If possible, the flame shall be applied at least 
10 mm from a corner. 
8.5 Replacement: 
The test shall be made on one specimen. If the 
specimen does not withstand the test, the test 
may be repeated on two further specimens, both 
of which shall then withstand the test. 
 
10 Evaluation of test results 
Replace with: 
The duration of burning (t
b
) shall not exceed 30 s. 
However, for printed circuit boards, it shall not 
exceed 15 s. 
The needle-flame test shall not be carried out on 
parts of material classified as V-0 or V-1 
 
 
 
 
Page 46 of 58 
 
Report No.: 
11008507 001 
National Differences 
Clause 
Requirement − Test 
Result – Remark 
Verdict 
 
Australian National Differences according to CB Bulletin No. 110A, June 2006 
according to IEC 60695-11-10, provided that the 
sample tested was not thicker than the relevant 
part. 
4.7.201.4 
Testing in the event of non-extinguishing material 
If parts, other than enclosures, do not withstand 
the glow-wire tests of 4.7.201.3, by failure to 
extinguish within 30 s after the removal of the 
glow-wire tip, the needle-flame test detailed in 
4.7.201.3 is made on all parts of non-metallic 
material which are within a distance of 50 mm or 
which are likely to be impinged upon by flame 
during the tests of 4.7.201.3. Parts shielded by a 
separate barrier which meets the needle-flame 
test need not to be tested. 
NOTE 1 - If the enclosure does not withstand the 
glow-wire test the equipment is considered to 
have failed to meet the requirement of clause 
4.7.201 without the need for consequential 
testing. 
NOTE 2 - If other parts do not withstand the glow-
wire test due to ignition of the tissue paper and if 
this indicates that burring or glowing particles can 
fall onto an external surface underneath the 
equipment, the equipment is considered to have 
failed to meet the requirement of clause 4.7.201 
without the need for consequential testing. 
NOTE 3 - Parts likely to be impinged upon by the 
flame are considered to be those within the 
envelope of a vertical cylinder having a radius of 
10 mm and a height equal to the height of the 
flame, positioned above the point of the material 
supporting in contact with or in close proximity to 
connections. 
Alternative test methods were 
not considered. 
N/A 
4.7.201.5 
Testing of printed boards 
The base material of printed boards is subjected 
to needle-flame test to Clause 4.7.201.3. The 
flame is applied to the edge of the board where 
the heat sink effect is lowest when the board is 
positioned as in normal use. The flame shall not 
be applied to an edge, consisting of broken 
perforations, unless the edge is less than 3 mm 
for a potential ignition source. 
The test is not carried out if the – 
-  Printed board does not carry any potential 
ignition source; 
-  Base material of printed boards, on which the 
available apparent power at a connection 
exceeds 15 VA operating at a voltage 
exceeding 50 V and equal or less than 400 V 
Alternative test methods were 
not considered. 
N/A 
 
 
 
 
Page 47 of 58 
 
Report No.: 
11008507 001 
National Differences 
Clause 
Requirement − Test 
Result – Remark 
Verdict 
 
Australian National Differences according to CB Bulletin No. 110A, June 2006 
(peak) a.c. or d.c. under normal operating 
conditions, is of flammability category FV-1 or 
better according to AS/NZS 4695.707, or the 
printed boards are protected by an enclosure 
meeting the flammability category FV-0 
according to AS/NZS 4695.707, or made of 
metal, having openings only for connecting 
wires which fill the opening completely, or  
-  Base material of printed boards, on which the 
available apparatus power at a connection 
exceeds 15 VA operating at a voltage 
exceeding 400 V (peak) a.c. or d.c. under 
normal operating conditions, and base material 
printed boards supporting spark gaps which 
provide protection against overvoltages, is of 
flammability category FV-0 according to 
AS/NSZ 4695.707 or the printed boards are 
contained in a metal enclosure, having 
openings only for connecting wires fill the 
openings completely. 
Compliance is determined using the smallest 
thickness of the material. 
NOTE - Available apparent power is the 
maximum apparent power, which can be drawn 
from the supplying circuit through a resistive load 
whose value is chosen to maximise the apparent 
power for more than 2 min when the circuit 
supplied is disconnected. 
6.2.2 
Add the following after the first paragraph: 
In Australia (this variation does not apply in New 
Zealand), compliance with 6.2.2 is checked by the 
tests of both 6.2.2.1 and 6.2.2.2. 
Delete the note. 
No TNV. 
N/A 
6.2.2.1 
Delete Note 2. 
Add the following after the first paragraph: 
In Australia (this variation does not apply in New 
Zealand), the electrical separation is subjected to 
10 impulses of alternating polarity, using the 
impulse test generator of annex N for 10/700 µs 
impulses. The interval between successive 
impulses is 60 s and the initial voltage, Uc, is: 
-  for 6.2.1 a):                  
   7.0 kV for hand-held telephones and for 
  headsets and 2.5 kV for other equipment; and 
-  for 6.2.1b) and 6.2.1c): 
   1.5 kV.  
No TNV. 
N/A 