Page 16 of 58 
 
Report No.: 
11008507 001 
 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
 
 
 
4.3.1 
Edges and corners 
Edges and corners of the 
enclosure are rounded. 
4.3.2 
Handles and manual controls; force (N) .............. :  No handles or controls provided. 
N/A 
4.3.3 
Adjustable controls  
No controls provided. 
N/A 
4.3.4 
Securing of parts 
Mechanical fixings in such a 
way designed that they will 
withstand mechanical stress 
occurring in normal use. 
4.3.5 
Connection of plugs and sockets 
No mismatch of connectors, 
plugs or sockets possible.  
4.3.6 
Direct plug-in equipment 
Not direct plug-in type. 
N/A 
 
Dimensions (mm) of mains plug for direct plug-in:   
N/A 
 
Torque and pull test of mains plug for direct 
plug-in; torque (Nm); pull (N) ............................... : 
 
N/A 
4.3.7 
Heating elements in earthed equipment 
No heating elements provided. 
N/A 
4.3.8 
Batteries 
No batteries.  
N/A 
4.3.9 
Oil and grease 
 
N/A 
4.3.10 
Dust, powders, liquids and gases 
 
N/A 
4.3.11 
Containers for liquids or gases 
 
N/A 
4.3.12 
Flammable liquids...............................................: 
 
N/A 
 
Quantity of liquid (l) .............................................: 
 
N/A 
 
Flash point (°C)...................................................: 
 
N/A 
4.3.13 
Radiation; type of radiation  ................................: 
See below 
4.3.13.1 
General 
 
4.3.13.2 
Ionizing radiation  
No ionizing radiations. 
N/A 
 
Measured radiation (pA/kg)  .................................:   
 
 
Measured high-voltage (kV)  ................................:   
 
 
Measured focus voltage (kV) ...............................:   
 
 
CRT markings  .....................................................:   
 
4.3.13.3 
Effect of ultraviolet (UV) radiation on materials 
No UV radiations. 
N/A 
 
Part, property, retention after test, flammability 
classification  ......................................................: 
 
N/A 
4.3.13.4 
Human exposure to ultraviolet (UV) radiation ....: 
 
N/A 
4.3.13.5 
Laser (including LEDs) 
Only indicator LED provided. 
 
Laser class .........................................................: 
LED Class 1. 
 
4.3.13.6 
Other types  ........................................................: 
No other radiations. 
N/A 
 
 
 
 
Page 17 of 58 
 
Report No.: 
11008507 001 
 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
 
 
 
 
4.4 
Protection against hazardous moving parts 
N/A 
4.4.1 
General 
 
N/A 
4.4.2 
Protection in operator access areas 
 
N/A 
4.4.3 
Protection in restricted access locations  
 
N/A 
4.4.4 
Protection in service access areas 
 
N/A 
 
4.5 
Thermal requirements 
4.5.1 
Maximum temperatures 
See appended table 4.5.1. 
 
Normal load condition per Annex L.....................: 
See 1.6.2. 
4.5.2 
Resistance to abnormal heat 
 
N/A 
 
4.6 
Openings in enclosures 
4.6.1 
Top and side openings 
No openings. 
 
Dimensions (mm)  ..............................................: 
 
 
4.6.2 
Bottoms of fire enclosures 
No openings. 
 
Construction of the bottom .................................: 
 
 
4.6.3 
Doors or covers in fire enclosures 
 
N/A 
4.6.4 
Openings in transportable equipment 
 
N/A 
4.6.5 
Adhesives for constructional purposes 
 
N/A 
 
Conditioning temperature (°C)/time (weeks) ......: 
 
 
 
4.7 
Resistance to fire 
4.7.1 
Reducing the risk of ignition and spread of flame 
See below. 
 
Method 1, selection and application of 
components wiring and materials 
Use of materials with the 
required flammability classes. 
 
Method 2, application of all of simulated fault 
condition tests 
Method 1 used. 
N/A 
4.7.2 
Conditions for a fire enclosure 
See below. 
4.7.2.1 
Parts requiring a fire enclosure 
See 4.7.2.2. 
N/A 
 
 
 
 
Page 18 of 58 
 
Report No.: 
11008507 001 
 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
 
 
 
4.7.2.2 
Parts not requiring a fire enclosure 
With having the following parts: 
Components in secondary 
(supplied by LPS adaptor) and 
mounted on PCB material of 
Flammability class V-1. 
the fire enclosure is not 
required. 
4.7.3 
Materials 
4.7.3.1 
General 
PCB rated accordingly. For 
details see table 1.5.1. 
4.7.3.2 
Materials for fire enclosures 
 
N/A 
4.7.3.3 
Materials for components and other parts outside 
fire enclosures 
 
N/A 
4.7.3.4 
Materials for components and other parts inside 
fire enclosures 
 
N/A 
4.7.3.5 
Materials for air filter assemblies 
No air filters provided. 
N/A 
4.7.3.6 
Materials used in high-voltage components 
No high voltage components 
provided. 
N/A 
 
ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS 
5.1 
Touch current and protective conductor current 
Class III equipment without TNV circuit. 
N/A 
5.1.1 
General 
 
N/A 
5.1.2 
Equipment under test (EUT) 
 
N/A 
5.1.3 
Test circuit 
 
N/A 
5.1.4 
Application of measuring instrument 
 
N/A 
5.1.5 
Test procedure 
 
N/A 
5.1.6 
Test measurements 
 
N/A 
 
Test voltage (V)  .................................................: 
 
 
 
Measured touch current (mA) ............................: 
 
 
 
Max. allowed touch current (mA)  .......................: 
 
 
 
Measured protective conductor current (mA)  ....: 
 
 
 
Max. allowed protective conductor current (mA) : 
 
 
5.1.7 
Equipment with touch current exceeding 3.5 mA :   
N/A 
5.1.8 
Touch currents to and from telecommunication 
networks and cable distribution systems and from 
telecommunication networks 
 
N/A 
 
 
 
 
Page 19 of 58 
 
Report No.: 
11008507 001 
 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
 
 
 
5.1.8.1 
Limitation of the touch current to a 
telecommunication network and a cable 
distribution system 
 
N/A 
 
Test voltage (V)  .................................................: 
 
 
 
Measured touch current (mA) ............................: 
 
 
 
Max. allowed touch current (mA)  .......................: 
 
 
5.1.8.2 
Summation of touch currents from 
telecommunication networks ..............................: 
 
N/A 
 
5.2 
Electric strength 
Class III equipment. 
N/A 
5.2.1 
General 
 
N/A 
5.2.2 
Test procedure  
 
N/A 
 
5.3 
Abnormal operating and fault conditions 
5.3.1 
Protection against overload and abnormal 
operation 
See below. 
5.3.2 
Motors 
No motors. 
N/A 
5.3.3 
Transformers 
No transformers. 
N/A 
5.3.4 
Functional insulation ...........................................: 
Method c) considered. Due to 
-  all components are 
mountedv on PCB of 
flammability V-1. 
-  no risk of electrical shock. 
no test had been performed. 
5.3.5 
Electromechanical components 
No electromechanical 
component provided. 
N/A 
5.3.6 
Simulation of faults 
None would cause hazards. 
N/A 
5.3.7 
Unattended equipment 
None of the listed components 
was provided. 
N/A 
5.3.8 
Compliance criteria for abnormal operating and 
fault conditions 
No tests are required. 
N/A 
 
CONNECTION TO TELECOMMUNICATION NETWORKS 
N/A 
6.1 
Protection of telecommunication network service persons, and users of other 
equipment connected to the network, from hazards in the equipment 
N/A 
6.1.1 
Protection from hazardous voltages 
N/A 
6.1.2 
Separation of the telecommunication network from earth 
N/A 
Page of 62