Report No.   152949 
 
ATTACHMENT: NATIONAL DIFFERENCES – SINGAPORE 
Test results according to Consumer Protection Information Booklet, 
2002 Ed., (Ver. 3) 
 
 
 
No 
Item  
Requirement 
Result - Remark 
Verdict 
, ref. Singapore Consumer Protection (Safety Requirements) - 
Information booklet - chapter 7 (page 21 - 24). Based on information by Singapore NCB – PSB 
Corp.
 
7 SAFETY AUTHORITY’S REQUIREMENTS
 
The Safety Authority monitors the safety of the controlled goods sold in Singapore by 
investigating all complaints, incidents and accidents reported to the authority. Experiences 
gained are translated into the Safety Authority’s Requirements. These requirements are to be 
fulfilled in addition to the applicable safety standards.
 
Applicable to all electrical products 
All appliances 
All appliances must be tested to 
230 VAC. 
Class III equipment. 
Unit is not intended for 
direct connection to a 
mains supply. 
N/A 
Voltage selector 
(voltage mis-match 
test) 
Appliance fitted with voltage 
selector shall be tested as follows: 
Connect appliance to 230 VAC 
mains with voltage selector switch 
to settings not suitable for 
operation at 230 VAC. 
Class III equipment. 
Unit is not intended 
for direct connection 
to a mains supply. 
N/A 
Tropical condition 
test 
All appliances (with tropical test 
requirements in applicable 
Standards) shall comply with the 
tropical condition test as stated in 
the relevant IEC Standards. 
Class III equipment. 
Unit is not intended for 
direct connection to a 
mains supply. 
Class I 
appliances  
(3-pin mains 
plug) 
All Class I appliances must be 
fitted with 3-pin mains plugs 
complied with SS 145/SS 472 that 
are registered with the Safety 
Authority.  
Class III equipment. 
Unit is not intended for 
direct connection to a 
mains supply. 
N/A 
Class II 
appliances 
(mains plug) 
a) All Class II appliances must be 
fitted with 2-pin mains plug 
(Appendix W) complied with IEC 
83: 1975 (Standard C5, Version II) 
or EN 50075: 1991.   
b) Class II appliances that are fitted 
with 3-pin mains plugs must use 
plugs that are complied with SS 
145 and registered with the Safety 
Authority. 
Class III equipment. 
N/A 
Appliances rated 
≥ 3 kW or 
connected to 
fixed wiring 
Electric appliance 
≥ 3 kW must be 
connected to fixed wiring. All 
connection to fixed wiring must be 
in accordance with Code of 
Practice CP5. 
Considered. 
N/A 
 
 
- Page 2 of 2 - 
 
 
 
 
Report No.   152949 
 
No 
Item  
Requirement 
Result - Remark 
Verdict 
Detachable power 
cord set (consists of 
mains plug, mains 
cord and appliance 
connector 
Detachable power cord set must 
be listed in the test report critical 
component list. 
Class III equipment. 
Unit is not intended for 
direct connection to a 
mains supply. 
N/A 
Circuit diagrams 
Circuit diagrams must be indicated 
with component’s values for 
products tested to IEC 60065 and 
IEC 60950. 
Not provided with this 
test report. 
Must be considered 
before marketing in 
Singapore. 
N/A 
10 
Circuit diagrams of 
electronic modules 
in electrical 
appliances 
Circuit diagrams of the electronic 
modules in the electrical 
appliances must be provided. 
Not provided with this 
test report. 
Must be considered 
before marketing in 
Singapore. 
N/A 
11 
Controlled goods 
likely to be treated 
as toy by children 
Controlled goods, having an 
enclosure, which is shaped and 
decorated so that it is likely to be 
treated as a toy by children, shall 
not be accepted for certification 
and registration. 
The equipment is not 
considered a toy. 
N/A 
Applicable to AC adaptor 
13 
3-pin AC adaptor 
Test report showing that the 3-pin 
complied with sub-clauses 12.1 & 
12.3 of SS 246 must be submitted. 
Cord set and wiring not 
evaluated. Suitable 
cord set / wiring and 
information shall be 
provided when 
marketing in 
Singapore. 
N/A 
14 
2-pin AC adaptor 
The 2-pin (Appendix W) shall 
comply with IEC 83: 1975 (Standard 
C5, Version II) or EN 50075 
Class IIII equipment. 
N/A 
15 
Detachable power 
supply cord set not 
supplied by 
Registered 
Supplier 
Registered Supplier who is not 
supplying the detachable power 
supply cord set together with the AC 
Adaptor must provide written 
instruction to its customer on the 
type of approved detachable power 
cord set to use. 
Must be considered 
before marketing in 
Singapore. 
N/A 
Applicable to computer products 
16 
CD/DVD ROM 
(used in personal 
computer) 
Test certificate showing that 
CD/DVD ROM has complied with 
IEC 825 must be provided. 
No CD/DVD ROM in 
the equipment. 
N/A 
17 
Modem Card (used 
in personal 
computer) 
Modem card incorporated in the 
personal computer must be tested 
at set level (sub-clauses 5.1 & 6 of 
IEC 60950) or at component level. 
No TNV provided. 
N/A 
 
IEC 60950 3rd Ed. 
- Page 1 of 1 - 
 
 
 Report 
No. 
152949 
 
ATTACHMENT: NATIONAL DIFFERENCES – UKRAINE 
Test results according to Online CB BULLETIN (Last modified date of 2007-05-29) 
 
 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
1.4.5 
In Ukraine the NOMINAL VOLTAGE is 220V for 
monophase or 380V for three-phase supply. 
Class III equipment. 
N/A 
1.5.8 
In Ukraine the components connected between phase 
and earthing or between phase and neutral terminal 
shall be calculated for the voltage between phases. 
Class III equipment. 
N/A
 
1.7.2 
In Ukraine for the APPARATUS of І CLASS the 
necessity of its obligatory earthing shall be indicated in 
the manuals. 
Class III equipment. 
N/A
 
2.3.3 
In Ukraine the method b) is not used. 
Considered. 
N/A 
6.2.2 
In Ukraine the both tests in 6.2.2.1 and 6.2.2.2 are 
applied. 
No TNV circuits. 
N/A 
6.2.2.1 
In Ukraine in 6.2.1 а) is used Uс 3,5 kV. 
No TNV circuits. 
N/A 
6.2.2.2 
In Ukraine in 6.2.1 а) is used 3,0 kV for telephones and 
headsets and 2,5 kV  for other equipment and in 6.2.1 
b) and с) is used 1,5 kV. 
No TNV circuits. 
N/A 
Annex N 
In Ukraine in 6.2.1 а) is used 3,0 kV for telephones and 
headsets and 2,5 kV  for other equipment, and in 6.2.1 
b) and с) is used 1,5 kV. 
No TNV circuits. 
N/A 
IEC 60950-1 (ed.2) 
 
- Page 1 of 7 - 
 
   
 
Report No.   152949 
 
ATTACHMENT: NATIONAL DIFFERENCES –
  US 
Test results according to ONLINE CB BULLETIN as of (2007-08-08)
 
 
Clause 
Requirements – Test 
Result – Remark 
Verdict 
The following is a summary of the key national differences based on national regulatory 
requirements, such as the National Electrical Code (NEC), ANSI/NFPA 70-2002, which are 
referenced in legislation and which form the basis for the rules and practices followed in 
electrical and building installations. The bi-national standard (CAN/CSA C22.2 No. 60950-1/UL/IEC 
60950-1, 2nd Edition) should be consulted for further details on the national differences 
summarized below
 
1.1.1 
Equipment able to be installed in accordance 
with the National Electrical Code ANSI/NFPA 70. 
Class III equipment. 
1.1.1 
Equipment able to be installed in accordance 
with ANSI/NFPA 75 and NEC Art. 645 unless 
intended for use outside of computer room and 
provided with such instructions. 
Class III equipment. 
P
 
1.1.2 Equipment 
in 
wire-line communication facilities 
serving high-voltage electric power stations 
operating at greater than 1kV are excluded. 
Class III equipment. 
N/A 
1.1.2 
Equipment intended for outdoor use. 
Equipment is not for outdoor use.
N/A
1.4.14 
For Pluggable Equipment Type A, the protection 
in the installation is assumed to be 20A. 
Class III equipment. 
P
 
1.5.1 
All IEC standards for components identified in 
Annex P.1 replaced by the relevant requirements 
of UL component standards in Annex P.1. 
All critical components are IEC, 
CSA and UL certified. Refer to 
appended table 1.5.1 in main CB 
Test Teport. 
1.5.1 
All IEC standards for components identified in 
Annex P.2 alternatively satisfied by the relevant 
requirements of UL component standards 
All critical components are IEC, 
CSA and UL certified. Refer to 
appended table 1.5.1 in main CB 
Test Teport. 
1.5.5 
Interconnecting cables acceptable for the 
application regarding voltage, current, 
temperature, flammability, mechanical 
serviceability and the like. 
Suitable flame rated cables 
provided. Refer to appended 
table 1.5.1 in main CB test 
report. 
1.5.5 
For other than limited power and TNV circuits, 
the type of output circuit identified for output 
connector. 
Considered. 
N/A 
1.5.5 
External cable assemblies that exceed 3.05 m in 
length to be types specified in the NEC 
Suitable flame rated cables 
provided. Refer to appended 
table 1.5.1 in main CB test 
report. 
1.5.5 
Detachable external interconnecting cables 3.05 
m or less in length and provided with equipment 
marked to identify the responsible organization 
and the designation for the cable 
Suitable flame rated cables 
provided. Refer to appended 
table 1.5.1 in main CB test 
report. 
1.5.5 
Building wiring and cable for use in ducts, 
plenums and other air handling space subject to 
special requirements and excluded from scope. 
No such cables evaluated. 
N/A 
1.5.5 
Telephone line and extension cords and the like 
comply with UL 1863 
No TNV circuitry. 
N/A 
1.6.1.2 
Equipment intended for connection to a d.c. 
power (mains) distribution system subjected to 
special circuit classification requirements (e.g., 
TNV-2) 
Not connected to DC power 
distribution system. 
N/A 
1.6.1.2 
Earthing of d.c. powered equipment provided. 
Not connected to DC power 
distribution system. 
N/A 
1.7 
Lamp replacement information indicated on 
lampholder in operator access area. 
No lamp in the equipment. 
N/A 