JBL RADIAL (serv.man5) EMC - CB Certificate ▷ View online
- Page 1 of 2 -
Report No. 152949
ATTACHMENT: NATIONAL DIFFERENCES – SINGAPORE
Test results according to Consumer Protection Information Booklet,
2002 Ed., (Ver. 3)
No
Item
Requirement
Result - Remark
Verdict
, ref. Singapore Consumer Protection (Safety Requirements) -
Information booklet - chapter 7 (page 21 - 24). Based on information by Singapore NCB – PSB
Corp.
Corp.
7 SAFETY AUTHORITY’S REQUIREMENTS
The Safety Authority monitors the safety of the controlled goods sold in Singapore by
investigating all complaints, incidents and accidents reported to the authority. Experiences
gained are translated into the Safety Authority’s Requirements. These requirements are to be
fulfilled in addition to the applicable safety standards.
investigating all complaints, incidents and accidents reported to the authority. Experiences
gained are translated into the Safety Authority’s Requirements. These requirements are to be
fulfilled in addition to the applicable safety standards.
Applicable to all electrical products
2
All appliances
All appliances must be tested to
230 VAC.
230 VAC.
Class III equipment.
Unit is not intended for
direct connection to a
mains supply.
Unit is not intended for
direct connection to a
mains supply.
N/A
3
Voltage selector
(voltage mis-match
test)
(voltage mis-match
test)
Appliance fitted with voltage
selector shall be tested as follows:
Connect appliance to 230 VAC
mains with voltage selector switch
to settings not suitable for
operation at 230 VAC.
selector shall be tested as follows:
Connect appliance to 230 VAC
mains with voltage selector switch
to settings not suitable for
operation at 230 VAC.
Class III equipment.
Unit is not intended
for direct connection
to a mains supply.
Unit is not intended
for direct connection
to a mains supply.
N/A
4
Tropical condition
test
test
All appliances (with tropical test
requirements in applicable
Standards) shall comply with the
tropical condition test as stated in
the relevant IEC Standards.
requirements in applicable
Standards) shall comply with the
tropical condition test as stated in
the relevant IEC Standards.
Class III equipment.
Unit is not intended for
direct connection to a
mains supply.
Unit is not intended for
direct connection to a
mains supply.
P
5
Class I
appliances
(3-pin mains
plug)
appliances
(3-pin mains
plug)
All Class I appliances must be
fitted with 3-pin mains plugs
complied with SS 145/SS 472 that
are registered with the Safety
Authority.
fitted with 3-pin mains plugs
complied with SS 145/SS 472 that
are registered with the Safety
Authority.
Class III equipment.
Unit is not intended for
direct connection to a
mains supply.
Unit is not intended for
direct connection to a
mains supply.
N/A
6
Class II
appliances
(mains plug)
appliances
(mains plug)
a) All Class II appliances must be
fitted with 2-pin mains plug
(Appendix W) complied with IEC
83: 1975 (Standard C5, Version II)
or EN 50075: 1991.
b) Class II appliances that are fitted
with 3-pin mains plugs must use
plugs that are complied with SS
145 and registered with the Safety
Authority.
fitted with 2-pin mains plug
(Appendix W) complied with IEC
83: 1975 (Standard C5, Version II)
or EN 50075: 1991.
b) Class II appliances that are fitted
with 3-pin mains plugs must use
plugs that are complied with SS
145 and registered with the Safety
Authority.
Class III equipment.
N/A
7
Appliances rated
≥ 3 kW or
connected to
fixed wiring
≥ 3 kW or
connected to
fixed wiring
Electric appliance
≥ 3 kW must be
connected to fixed wiring. All
connection to fixed wiring must be
in accordance with Code of
Practice CP5.
connection to fixed wiring must be
in accordance with Code of
Practice CP5.
Considered.
N/A
- Page 2 of 2 -
Report No. 152949
No
Item
Requirement
Result - Remark
Verdict
8
Detachable power
cord set (consists of
mains plug, mains
cord and appliance
connector
cord set (consists of
mains plug, mains
cord and appliance
connector
Detachable power cord set must
be listed in the test report critical
component list.
be listed in the test report critical
component list.
Class III equipment.
Unit is not intended for
direct connection to a
mains supply.
Unit is not intended for
direct connection to a
mains supply.
N/A
9
Circuit diagrams
Circuit diagrams must be indicated
with component’s values for
products tested to IEC 60065 and
IEC 60950.
with component’s values for
products tested to IEC 60065 and
IEC 60950.
Not provided with this
test report.
Must be considered
before marketing in
Singapore.
test report.
Must be considered
before marketing in
Singapore.
N/A
10
Circuit diagrams of
electronic modules
in electrical
appliances
electronic modules
in electrical
appliances
Circuit diagrams of the electronic
modules in the electrical
appliances must be provided.
modules in the electrical
appliances must be provided.
Not provided with this
test report.
Must be considered
before marketing in
Singapore.
test report.
Must be considered
before marketing in
Singapore.
N/A
11
Controlled goods
likely to be treated
as toy by children
likely to be treated
as toy by children
Controlled goods, having an
enclosure, which is shaped and
decorated so that it is likely to be
treated as a toy by children, shall
not be accepted for certification
and registration.
enclosure, which is shaped and
decorated so that it is likely to be
treated as a toy by children, shall
not be accepted for certification
and registration.
The equipment is not
considered a toy.
considered a toy.
N/A
Applicable to AC adaptor
13
3-pin AC adaptor
Test report showing that the 3-pin
complied with sub-clauses 12.1 &
12.3 of SS 246 must be submitted.
complied with sub-clauses 12.1 &
12.3 of SS 246 must be submitted.
Cord set and wiring not
evaluated. Suitable
cord set / wiring and
information shall be
provided when
marketing in
Singapore.
evaluated. Suitable
cord set / wiring and
information shall be
provided when
marketing in
Singapore.
N/A
14
2-pin AC adaptor
The 2-pin (Appendix W) shall
comply with IEC 83: 1975 (Standard
C5, Version II) or EN 50075
comply with IEC 83: 1975 (Standard
C5, Version II) or EN 50075
Class IIII equipment.
N/A
15
Detachable power
supply cord set not
supplied by
Registered
Supplier
supply cord set not
supplied by
Registered
Supplier
Registered Supplier who is not
supplying the detachable power
supply cord set together with the AC
Adaptor must provide written
instruction to its customer on the
type of approved detachable power
cord set to use.
supplying the detachable power
supply cord set together with the AC
Adaptor must provide written
instruction to its customer on the
type of approved detachable power
cord set to use.
Must be considered
before marketing in
Singapore.
before marketing in
Singapore.
N/A
Applicable to computer products
16
CD/DVD ROM
(used in personal
computer)
(used in personal
computer)
Test certificate showing that
CD/DVD ROM has complied with
IEC 825 must be provided.
CD/DVD ROM has complied with
IEC 825 must be provided.
No CD/DVD ROM in
the equipment.
the equipment.
N/A
17
Modem Card (used
in personal
computer)
in personal
computer)
Modem card incorporated in the
personal computer must be tested
at set level (sub-clauses 5.1 & 6 of
IEC 60950) or at component level.
personal computer must be tested
at set level (sub-clauses 5.1 & 6 of
IEC 60950) or at component level.
No TNV provided.
N/A
IEC 60950 3rd Ed.
- Page 1 of 1 -
Report
No.
152949
ATTACHMENT: NATIONAL DIFFERENCES – UKRAINE
Test results according to Online CB BULLETIN (Last modified date of 2007-05-29)
Clause
Requirement - Test
Result - Remark
Verdict
1.4.5
In Ukraine the NOMINAL VOLTAGE is 220V for
monophase or 380V for three-phase supply.
monophase or 380V for three-phase supply.
Class III equipment.
N/A
1.5.8
In Ukraine the components connected between phase
and earthing or between phase and neutral terminal
shall be calculated for the voltage between phases.
and earthing or between phase and neutral terminal
shall be calculated for the voltage between phases.
Class III equipment.
N/A
1.7.2
In Ukraine for the APPARATUS of І CLASS the
necessity of its obligatory earthing shall be indicated in
the manuals.
necessity of its obligatory earthing shall be indicated in
the manuals.
Class III equipment.
N/A
2.3.3
In Ukraine the method b) is not used.
Considered.
N/A
6.2.2
In Ukraine the both tests in 6.2.2.1 and 6.2.2.2 are
applied.
applied.
No TNV circuits.
N/A
6.2.2.1
In Ukraine in 6.2.1 а) is used Uс 3,5 kV.
No TNV circuits.
N/A
6.2.2.2
In Ukraine in 6.2.1 а) is used 3,0 kV for telephones and
headsets and 2,5 kV for other equipment and in 6.2.1
b) and с) is used 1,5 kV.
headsets and 2,5 kV for other equipment and in 6.2.1
b) and с) is used 1,5 kV.
No TNV circuits.
N/A
Annex N
In Ukraine in 6.2.1 а) is used 3,0 kV for telephones and
headsets and 2,5 kV for other equipment, and in 6.2.1
b) and с) is used 1,5 kV.
headsets and 2,5 kV for other equipment, and in 6.2.1
b) and с) is used 1,5 kV.
No TNV circuits.
N/A
IEC 60950-1 (ed.2)
- Page 1 of 7 -
Report No. 152949
ATTACHMENT: NATIONAL DIFFERENCES –
US
Test results according to ONLINE CB BULLETIN as of (2007-08-08)
Clause
Requirements – Test
Result – Remark
Verdict
The following is a summary of the key national differences based on national regulatory
requirements, such as the National Electrical Code (NEC), ANSI/NFPA 70-2002, which are
referenced in legislation and which form the basis for the rules and practices followed in
electrical and building installations. The bi-national standard (CAN/CSA C22.2 No. 60950-1/UL/IEC
60950-1, 2nd Edition) should be consulted for further details on the national differences
summarized below
requirements, such as the National Electrical Code (NEC), ANSI/NFPA 70-2002, which are
referenced in legislation and which form the basis for the rules and practices followed in
electrical and building installations. The bi-national standard (CAN/CSA C22.2 No. 60950-1/UL/IEC
60950-1, 2nd Edition) should be consulted for further details on the national differences
summarized below
1.1.1
Equipment able to be installed in accordance
with the National Electrical Code ANSI/NFPA 70.
with the National Electrical Code ANSI/NFPA 70.
Class III equipment.
P
1.1.1
Equipment able to be installed in accordance
with ANSI/NFPA 75 and NEC Art. 645 unless
intended for use outside of computer room and
provided with such instructions.
with ANSI/NFPA 75 and NEC Art. 645 unless
intended for use outside of computer room and
provided with such instructions.
Class III equipment.
P
1.1.2 Equipment
in
wire-line communication facilities
serving high-voltage electric power stations
operating at greater than 1kV are excluded.
operating at greater than 1kV are excluded.
Class III equipment.
N/A
1.1.2
Equipment intended for outdoor use.
Equipment is not for outdoor use.
N/A
1.4.14
For Pluggable Equipment Type A, the protection
in the installation is assumed to be 20A.
in the installation is assumed to be 20A.
Class III equipment.
P
1.5.1
All IEC standards for components identified in
Annex P.1 replaced by the relevant requirements
of UL component standards in Annex P.1.
Annex P.1 replaced by the relevant requirements
of UL component standards in Annex P.1.
All critical components are IEC,
CSA and UL certified. Refer to
appended table 1.5.1 in main CB
Test Teport.
CSA and UL certified. Refer to
appended table 1.5.1 in main CB
Test Teport.
P
1.5.1
All IEC standards for components identified in
Annex P.2 alternatively satisfied by the relevant
requirements of UL component standards
Annex P.2 alternatively satisfied by the relevant
requirements of UL component standards
All critical components are IEC,
CSA and UL certified. Refer to
appended table 1.5.1 in main CB
Test Teport.
CSA and UL certified. Refer to
appended table 1.5.1 in main CB
Test Teport.
P
1.5.5
Interconnecting cables acceptable for the
application regarding voltage, current,
temperature, flammability, mechanical
serviceability and the like.
application regarding voltage, current,
temperature, flammability, mechanical
serviceability and the like.
Suitable flame rated cables
provided. Refer to appended
table 1.5.1 in main CB test
report.
provided. Refer to appended
table 1.5.1 in main CB test
report.
P
1.5.5
For other than limited power and TNV circuits,
the type of output circuit identified for output
connector.
the type of output circuit identified for output
connector.
Considered.
N/A
1.5.5
External cable assemblies that exceed 3.05 m in
length to be types specified in the NEC
length to be types specified in the NEC
Suitable flame rated cables
provided. Refer to appended
table 1.5.1 in main CB test
report.
provided. Refer to appended
table 1.5.1 in main CB test
report.
P
1.5.5
Detachable external interconnecting cables 3.05
m or less in length and provided with equipment
marked to identify the responsible organization
and the designation for the cable
m or less in length and provided with equipment
marked to identify the responsible organization
and the designation for the cable
Suitable flame rated cables
provided. Refer to appended
table 1.5.1 in main CB test
report.
provided. Refer to appended
table 1.5.1 in main CB test
report.
P
1.5.5
Building wiring and cable for use in ducts,
plenums and other air handling space subject to
special requirements and excluded from scope.
plenums and other air handling space subject to
special requirements and excluded from scope.
No such cables evaluated.
N/A
1.5.5
Telephone line and extension cords and the like
comply with UL 1863
comply with UL 1863
No TNV circuitry.
N/A
1.6.1.2
Equipment intended for connection to a d.c.
power (mains) distribution system subjected to
special circuit classification requirements (e.g.,
TNV-2)
power (mains) distribution system subjected to
special circuit classification requirements (e.g.,
TNV-2)
Not connected to DC power
distribution system.
distribution system.
N/A
1.6.1.2
Earthing of d.c. powered equipment provided.
Not connected to DC power
distribution system.
distribution system.
N/A
1.7
Lamp replacement information indicated on
lampholder in operator access area.
lampholder in operator access area.
No lamp in the equipment.
N/A