JBL RADIAL (serv.man5) EMC - CB Certificate ▷ View online
IEC 60950 3rd Ed., 1999
- Page 8 of 14 -
Report No. 152949
Clause
Requirement - Test
Result - Remark
Verdict
5.1.6
Replacement:
Replace Table 5A.
Replace Table 5A.
Class III equipment.
N/A
Type of equipment
Terminal A of
measuring instrument
connected to:
Maximum
TOUCH
CURRENT
mA r.m.s.
1)
Maximum
PROTECTIVE
CONDUCTOR CURRENT
ALL equipment
Accessible parts
and circuits not
connected to
protective earth
and circuits not
connected to
protective earth
0,25 -
HAND-HELD Equipment
main
protective earthing
terminal
(if any)
CLASS I
EQUIPMENT
terminal
(if any)
CLASS I
EQUIPMENT
0,75 -
MOVABLE (other than
HAND_HELD, but
including
TRANSPORTABLE
EQUIPMENT
HAND_HELD, but
including
TRANSPORTABLE
EQUIPMENT
3,5 -
STATIONARY,
PLUGGABLE TYPE A
PLUGGABLE TYPE A
3,5 -
ALL other STATIONARY
EQUIPMENT
-
EQUIPMENT
-
not subject to the
conditions of 5.1.7
conditions of 5.1.7
- subject
to
the
conditions of 5.1.7
3,5
-
-
5 % of input current
HAND-HELD Equipment
main
protective earthing
terminal
(if any)
CLASS 0I
EQUIPMENT
terminal
(if any)
CLASS 0I
EQUIPMENT
0,5 -
Others 1,0
-
1)
If peak values of TOUCH-CURRENT are measured, the maximum values obtained by multiplying
the r.m.s. values by 1,414.
5.3.8.2
Replacement:
Replace 3rd Item as follows.
Replace 3rd Item as follows.
- BASIC INSULATION between the PRIMARY
CIRCUIT and accessible conductive parts of CLASS I
or 0I EQUIPMENT;
CIRCUIT and accessible conductive parts of CLASS I
or 0I EQUIPMENT;
Class III equipment.
N/A
Annex A
Addition:
Add the subclause A.101 with the title “Flammability
tests for classifying materials VTM” and the following:
tests for classifying materials VTM” and the following:
Thin sheet materials shall comply with ISO 9773.
All materials have suitable
flame class, no testing
required.
flame class, no testing
required.
N/A
Annex G
Addition:
Add the following to the Note for Table G.1.
2. In Japan, MAINS TRANSIENT VOLTAGE for
equipment with a Nominal AC MAINS SUPPLY
VOLTAGE of 100V is to be decided based on the
column where Nominal AC MAINS SUPPLY
VOLTAGE in Table G.1 is 150V.
equipment with a Nominal AC MAINS SUPPLY
VOLTAGE of 100V is to be decided based on the
column where Nominal AC MAINS SUPPLY
VOLTAGE in Table G.1 is 150V.
Annex G not used.
N/A
IEC 60950 3rd Ed., 1999
- Page 9 of 14 -
Report No. 152949
Annex P
Addition:
Add “IEC 61965:2000, Mechanical Safety for Cathode
Ray Tubes”.
Ray Tubes”.
Added, No CRT in
equipment.
equipment.
N/A
Annex U
Replacement:
Replace 2nd paragraph.
Replace 2nd paragraph.
This annex covers to round winding wires having
diameters between 0.05 mm and 5.00 mm.
diameters between 0.05 mm and 5.00 mm.
No TIW used.
N/A
U.2.1
Replacement:
Electric strength
The test sample is prepared according to IEC 60851-
5:1997, 4.4.1 (for a twisted pair). The sample is then
subjected to the test of 5.2.2 of this standard, with a
test voltage not less than twice the appropriate voltage
in table 5B (see 5.2.2) of this standard. However, the
minimum values shall be as follows:
Electric strength
The test sample is prepared according to IEC 60851-
5:1997, 4.4.1 (for a twisted pair). The sample is then
subjected to the test of 5.2.2 of this standard, with a
test voltage not less than twice the appropriate voltage
in table 5B (see 5.2.2) of this standard. However, the
minimum values shall be as follows:
- for BASIC INSULATION or SUPPLEMENTARY
INSULATION, 3000 V, or;
INSULATION, 3000 V, or;
- for REINFORCED INSULATION, 6000 V.
No TIW used.
N/A
IEC 60950 3rd Ed., 1999
- Page 10 of 14 -
Report No. 152949
Clause
Requirement - Test
Result - Remark
Verdict
U.2.2
Replacement:
Flexibility and adherence
Test 8 of IEC 60851-3:1996, 5.1.1, using the mandrel
diameters of table U.1. The test sample is then
examined in accordance with IEC 60851-3:1996,
5.1.1.4, followed by the test of 5.2.2 of this standard
except applying the test voltage between the wire and
the mandrel. A test voltage shall be the appropriate
voltage in table 5B (see 5.2.2) of this standard.
However, the minimum values shall be as follows:
-
Flexibility and adherence
Test 8 of IEC 60851-3:1996, 5.1.1, using the mandrel
diameters of table U.1. The test sample is then
examined in accordance with IEC 60851-3:1996,
5.1.1.4, followed by the test of 5.2.2 of this standard
except applying the test voltage between the wire and
the mandrel. A test voltage shall be the appropriate
voltage in table 5B (see 5.2.2) of this standard.
However, the minimum values shall be as follows:
-
for BASIC INSULATION or SUPPLEMENTARY
INSULATION, 1500 V, or;
INSULATION, 1500 V, or;
- for REINFORCED INSULATION, 3000 V.
No TIW used.
N/A
Table U.1
Replacement:
Mandrel diameter
Mandrel diameter
The tension to be applied to the wire during winding on
the mandrel is calculated from the wire diameter to be
equivalent to 118 Mpa ± 10 % (118 N/mm2 ± 10 %).
No TIW used.
N/A
U.2.3
Replacement:
Replace the first paragraph with the following.
Test 9 of IEC 60851-6:1996, followed by the electric
strength test of 5.2.2 of this standard except applying
the test voltage between the wire and the mandrel. A
test voltage shall be the appropriate voltage in table 5B
(see 5.2.2) of this standard.
However, the minimum values shall be as follows:
- for BASIC INSULATION or SUPPLEMENTARY
INSULATION, 1500 V, or;
Test 9 of IEC 60851-6:1996, followed by the electric
strength test of 5.2.2 of this standard except applying
the test voltage between the wire and the mandrel. A
test voltage shall be the appropriate voltage in table 5B
(see 5.2.2) of this standard.
However, the minimum values shall be as follows:
- for BASIC INSULATION or SUPPLEMENTARY
INSULATION, 1500 V, or;
- for REINFORCED INSULATION, 3000 V.
Considered.
N/A
IEC 60950 3rd Ed., 1999
- Page 11 of 14 -
Report No. 152949
U.2.4
Replacement:
Replace the third paragraph describing the test voltage
with the following.
The test voltage shall not be less than the appropriate
voltage in table 5B (see 5.2.2) of this standard.
However, the minimum values shall be as follows:
- for BASIC INSULATION or SUPPLEMENTARY
INSULATION, 1500 V, or;
- for REINFORCED INSULATION, 3000 V.
It is applied between the shot and the conductor.
with the following.
The test voltage shall not be less than the appropriate
voltage in table 5B (see 5.2.2) of this standard.
However, the minimum values shall be as follows:
- for BASIC INSULATION or SUPPLEMENTARY
INSULATION, 1500 V, or;
- for REINFORCED INSULATION, 3000 V.
It is applied between the shot and the conductor.
Considered.
N/A
U.3.1
Replacement:
Replace with the following.
The test voltage for ROUTINE TESTING shall be the
appropriate voltage in table 5B (see 5.2.2) of this
standard. Howeve, the minimum values shall be as
follows:
- for BASIC INSULATION or SUPPLEMENTARY
INSULATION, 1500 V r.m.s. or 2100 V peak, or;
- for REINFORCED INSULATION, 3000 V r.m.s. or
4200 V peak.
The test voltage for ROUTINE TESTING shall be the
appropriate voltage in table 5B (see 5.2.2) of this
standard. Howeve, the minimum values shall be as
follows:
- for BASIC INSULATION or SUPPLEMENTARY
INSULATION, 1500 V r.m.s. or 2100 V peak, or;
- for REINFORCED INSULATION, 3000 V r.m.s. or
4200 V peak.
Considered.
N/A
U.3.2
Replacement:
Replace with the following.
Twisted pair samples shall be tested in accordance
with IEC 60851-5:1996, 4.4.1. The minimum
breakdown voltage shall not be less than twice the
appropriate voltage in table 5B (see 5.2.2) of this
standard. However, the minimum values shallbe as
follows:
- for BASIC INSULATION or SUPPLEMENTARY
INSULATION, 3000 V r.m.s. or 4200 V peak, or;
- for REINFORCED INSULATION, 6000 V r.m.s. or
8400 V peak.
Twisted pair samples shall be tested in accordance
with IEC 60851-5:1996, 4.4.1. The minimum
breakdown voltage shall not be less than twice the
appropriate voltage in table 5B (see 5.2.2) of this
standard. However, the minimum values shallbe as
follows:
- for BASIC INSULATION or SUPPLEMENTARY
INSULATION, 3000 V r.m.s. or 4200 V peak, or;
- for REINFORCED INSULATION, 6000 V r.m.s. or
8400 V peak.
Considered.
N/A
Annex JA
Addition:
Add a new annex with the following contents.
Add a new annex with the following contents.
Annex JA
(normative)
Document shredding machines
Document shredding machines shall also comply with
the requirements of this annex except those of
STATIONARY EQUIPMENT used by connecting
directly to an AC MAINS SUPPLY of three-phase 200V
or more.
the requirements of this annex except those of
STATIONARY EQUIPMENT used by connecting
directly to an AC MAINS SUPPLY of three-phase 200V
or more.
Considered.
N/A