JBL RADIAL (serv.man5) EMC - CB Certificate ▷ View online
IEC 60950-1 (ed.2)
- Page 4 of 6 -
Report No. 152949
TRF No. CSA60950-1-07A/bl070423
OTHER DIFFERENCES
The following key national differences are based on requirements other than national regulatory requirements.
1.5.1
The following key national differences are based on requirements other than national regulatory requirements.
1.5.1
Some components and materials associated with the risk of
fire, electric shock, or personal injury are required to have
component or material ratings in accordance with the
applicable national (Canadian and/or U.S.) component or
material standard requirements. These components include:
attachment plugs, battery packs (rechargeable type, used
with transportable equipment), cathode ray tubes, circuit
breakers, communication circuit accessories, connectors
(used for current interruption of non-LPS circuits), cord sets
and power supply cords, direct plug-in equipment,
enclosures (outdoor), flexible cords and cables, fuses
(branch circuit), fuseholders, ground-fault current
interrupters, industrial control equipment, insulating tape,
interconnecting cables, lampholders, limit controls, printed
wiring, protectors for communications circuits, receptacles,
solid state controls, supplementary protectors, switches
(including interlock switches), thermal cutoffs, thermostats,
(multi-layer) transformer winding wire, transient voltage
surge suppressors, tubing, wire connectors, and wire and
cables.
fire, electric shock, or personal injury are required to have
component or material ratings in accordance with the
applicable national (Canadian and/or U.S.) component or
material standard requirements. These components include:
attachment plugs, battery packs (rechargeable type, used
with transportable equipment), cathode ray tubes, circuit
breakers, communication circuit accessories, connectors
(used for current interruption of non-LPS circuits), cord sets
and power supply cords, direct plug-in equipment,
enclosures (outdoor), flexible cords and cables, fuses
(branch circuit), fuseholders, ground-fault current
interrupters, industrial control equipment, insulating tape,
interconnecting cables, lampholders, limit controls, printed
wiring, protectors for communications circuits, receptacles,
solid state controls, supplementary protectors, switches
(including interlock switches), thermal cutoffs, thermostats,
(multi-layer) transformer winding wire, transient voltage
surge suppressors, tubing, wire connectors, and wire and
cables.
All critical components are
IEC, CSA, or UL certified.
See appended table 1.5.1
in this report.
IEC, CSA, or UL certified.
See appended table 1.5.1
in this report.
P
1.6.1.2
A circuit for connection to the DC Mains Supply is classified
as either a SELV Circuit, TNV-2 Circuit or Hazardous
Voltage Circuit depending on the maximum operating
voltage of the supply. This maximum operating voltage shall
include consideration of the battery charging “float voltage”
associated with the intended supply system, regardless of
the marked power rating of the equipment.
as either a SELV Circuit, TNV-2 Circuit or Hazardous
Voltage Circuit depending on the maximum operating
voltage of the supply. This maximum operating voltage shall
include consideration of the battery charging “float voltage”
associated with the intended supply system, regardless of
the marked power rating of the equipment.
Not connected to DC
power distribution system.
power distribution system.
N/A
2.3.1
For TNV-2 and TNV-3 circuits with other than ringing signals
and with voltages exceeding 42.4 Vpeak or 60 Vd.c., the
maximum acceptable current through a 2000 ohm resistor
(or greater) connected across the voltage source with other
loads disconnected is 7.1 mA peak or 30 mA d.c. under
normal operating conditions.
and with voltages exceeding 42.4 Vpeak or 60 Vd.c., the
maximum acceptable current through a 2000 ohm resistor
(or greater) connected across the voltage source with other
loads disconnected is 7.1 mA peak or 30 mA d.c. under
normal operating conditions.
No TNV circuitry.
N/A
2.3.2.1
No TNV circuitry.
N/A
2.6.3.4
Protective bonding conductors of non-standard protective
bonding constructions (e.g., printed circuit traces) subjected
to the additional limited short circuit test conditions specified,
if required.
bonding constructions (e.g., printed circuit traces) subjected
to the additional limited short circuit test conditions specified,
if required.
Class III equipment.
P
4.2.8.1
Enclosures around CRTs with a face diameter of 160 mm or
more are provided with suitable enclosure to reduce the risk
of injury due to the implosion of the CRT.
more are provided with suitable enclosure to reduce the risk
of injury due to the implosion of the CRT.
No CRTs in the equipment.
N/A
Projected area of opening ...................................... :
Minor dimension of projected area ........................ :
Minor dimension of projected area ........................ :
⎯
4.2.11
For equipment intended for mounting on racks and provided
with slide/rails allowing the equipment to slide away from the
rack for installation, service and maintenance, additional
construction, performance and marking requirements are
applicable to determine the adequacy of the slide/rails.
with slide/rails allowing the equipment to slide away from the
rack for installation, service and maintenance, additional
construction, performance and marking requirements are
applicable to determine the adequacy of the slide/rails.
Equipment is not provided
with slide/rails.
with slide/rails.
N/A
IEC 60950-1 (ed.2)
- Page 5 of 6 -
Report No. 152949
TRF No. CSA60950-1-07A/bl070423
4.3.2
Equipment with handles is required to comply with special
loading tests.
loading tests.
The equipment has no
handles.
handles.
N/A
5.1.8.3
Equipment intended to receive telecommunication ringing
signals is required to comply with a special touch current
measurement tests.
signals is required to comply with a special touch current
measurement tests.
No TNV circuitry.
N/A
Ringing ports provided: ..........................................
Simulation provided to: ..........................................
Measured total touch current : ...............................
Simulation provided to: ..........................................
Measured total touch current : ...............................
⎯
5.3.7
N/A
6.4
Equipment intended for connection to telecommunication
network outside plant cable is required to be protected
against overvoltage from power line crosses in accordance
with 6.4 and Annex NAC.
network outside plant cable is required to be protected
against overvoltage from power line crosses in accordance
with 6.4 and Annex NAC.
No TNV circuitry.
N/A
M.2
Continuous ringing signals up to 16 mA only are permitted if
the equipment is subjected to special installation and
performance restrictions.
the equipment is subjected to special installation and
performance restrictions.
No TNV circuitry.
N/A
Annex
NAD
NAD
Equipment connected to a telecommunication and cable
distribution networks and supplied with an earphone
intended to be held against, or in the ear is required to
comply with special acoustic pressure requirements.
distribution networks and supplied with an earphone
intended to be held against, or in the ear is required to
comply with special acoustic pressure requirements.
N/A
Annex
NAF
NAF
Document (paper) shredders likely to be used in a home or
home office (Pluggable Equipment Type A plug
configuration) are required to comply with additional
requirements, including markings/instructions, protection
against inadvertent reactivation of a safety interlock,
disconnection from the mains supply (via provision of an
isolating switch), and protection against operator access
(accessibility determined via new accessibility probe &
probe/wedge).
home office (Pluggable Equipment Type A plug
configuration) are required to comply with additional
requirements, including markings/instructions, protection
against inadvertent reactivation of a safety interlock,
disconnection from the mains supply (via provision of an
isolating switch), and protection against operator access
(accessibility determined via new accessibility probe &
probe/wedge).
Equipment is not a paper
shredder.
shredder.
N/A
IEC 60950-1 (ed.2)
- Page 6 of 6 -
Report No. 152949
TRF No. CSA60950-1-07A/bl070423
Annex NAF
Household/home office Document shredders
NAF1.7
Markings and Instructions
N/A
NAF 1.7.15 Symbols alerting the user to the following
considerations are provided adjacent to the
document feed opening. These symbols are
explained in the instructions:
document feed opening. These symbols are
explained in the instructions:
N/A
Product is not intended for use by children (product
is not a toy) ............................................................. :
is not a toy) ............................................................. :
N/A
Avoid touching the document feed opening with
hands ...................................................................... :
hands ...................................................................... :
N/A
Avoid clothing touching the document feed opening
................................................................................ :
................................................................................ :
N/A
Keep aerosol products away (applicable for product
with brush motor only) ............................................ :
with brush motor only) ............................................ :
N/A
The
(ISO 7000-0434) symbol to alert user to
important operating, maintenance and/or servicing
instructions and the explanation of above symbols
instructions and the explanation of above symbols
N/A
Marking is permanent, comprehensible and easily
discernible on the equipment.
discernible on the equipment.
N/A
NAF 2.8.3 Safety interlock can not be activated by articulated
accessibility probe (NAF.1)
N/A
N/A
NAF 3.4
Isolation switch complying with 3.4.2 is provided to
disconnect power to hazardous moving parts
disconnect power to hazardous moving parts
N/A
On/off marking is provided for two position switch .. :
N/A
Off marking for multi-position switch ...................... :
N/A
N/A
NAF 4.4
Protection against hazardous moving parts
N/A
Accessibility probe (Fig NAF.1) is inserted without
force into each opening and did not contact
hazardous moving parts
force into each opening and did not contact
hazardous moving parts
N/A
Operator accessible guards are removed and
Accessibility wedge is inserted into each opening
according without contacting mechanical hazards:
Accessibility wedge is inserted into each opening
according without contacting mechanical hazards:
⎯
Strip-cut
(45N): ....................................................... :
N/A
Cross-cut
(90N)
.......................................................
:
N/A
IEC 60950 3
rd
Ed.
- Page 1 of 1 -
Report
No.
152949
ATTACHMENT: NATIONAL DIFFERENCES – CHINA
Test results according to ONLINE CB BULLETIN (Last modified date of 2007-5-29)
Clause
Requirement - Test
Result - Remark
Verdict
1.4.5
1.4.5 second paragraph replaced by:
If the equipment is intended for direct
connection to an AC MAINS SUPPLY, the
tolerances on RATED VOLTAGE shall be
taken as +10 % and –10 %,unless:
If the equipment is intended for direct
connection to an AC MAINS SUPPLY, the
tolerances on RATED VOLTAGE shall be
taken as +10 % and –10 %,unless:
Class III equipment.
N/A
1.7.1
1.7.1 fifth paragraph replaced by:
When single rated voltage is given, it should
be marked 220 V; when a rating range is
given, the voltage range shall have a
hyphen (-) between the minimum and
maximum RATED VOLTAGES and should
cover 220 V; When multiple RATED
VOLTAGES or RATED VOLTAGE RANGES
are given, they shall be separated by a solidus
(/) and one of them must be 220 V and also
factory default setting should be 220 V.
RATED FREQUENCY or RATED
FREQUENCY RANGE should be 50Hz or
cover 50Hz, unless the equipment is designed
for d.c.
When single rated voltage is given, it should
be marked 220 V; when a rating range is
given, the voltage range shall have a
hyphen (-) between the minimum and
maximum RATED VOLTAGES and should
cover 220 V; When multiple RATED
VOLTAGES or RATED VOLTAGE RANGES
are given, they shall be separated by a solidus
(/) and one of them must be 220 V and also
factory default setting should be 220 V.
RATED FREQUENCY or RATED
FREQUENCY RANGE should be 50Hz or
cover 50Hz, unless the equipment is designed
for d.c.
only;
Class III equipment.
N/A
1.7.12
1.7.12 replaced by:
Instructions and equipment marking related to
safety shall be written in simplified Chinese in
which the equipment is to be installed.
Instructions and equipment marking related to
safety shall be written in simplified Chinese in
which the equipment is to be installed.
Must be considered before
marketing in China.
marketing in China.
N/A
3.2.1
3.2.1 Add at the end of the first paragraph:
Plugs of apparatus which are intended for the
connection of the mains supply should comply
with requirements of GB1002.
Plugs of apparatus which are intended for the
connection of the mains supply should comply
with requirements of GB1002.
Class III equipment.
N/A