JBL RADIAL (serv.man5) EMC - CB Certificate ▷ View online
Page 3 of 11
Report No.: 152949
IEC60950_1B - ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
IEC 60950-1, GROUP DIFFERENCES (CENELEC common modifications EN)
Clause
Requirement + Test
Result - Remark
Verdict
c) it is permitted for PLUGGABLE EQUIPMENT
TYPE B or PERMANENTLY CONNECTED
EQUIPMENT, to rely on dedicated overcurrent
and short-circuit protection in the building
installation, provided that the means of protection,
e.g. fuses or circuit breakers, is fully specified in
the installation instructions.
If reliance is placed on protection in the building
installation, the installation instructions shall so
state, except that for PLUGGABLE EQUIPMENT
TYPE A the building installation shall be regarded
as providing protection in accordance with the
rating of the wall socket outlet.
TYPE B or PERMANENTLY CONNECTED
EQUIPMENT, to rely on dedicated overcurrent
and short-circuit protection in the building
installation, provided that the means of protection,
e.g. fuses or circuit breakers, is fully specified in
the installation instructions.
If reliance is placed on protection in the building
installation, the installation instructions shall so
state, except that for PLUGGABLE EQUIPMENT
TYPE A the building installation shall be regarded
as providing protection in accordance with the
rating of the wall socket outlet.
2.7.2
This subclause has been declared ‘void’.
Considered. N/A
3.2.3
Delete the NOTE in Table 3A, and delete also in
this table the conduit sizes in parentheses.
this table the conduit sizes in parentheses.
Considered. N/A
3.2.5.1
Replace
“60245 IEC 53” by “H05 RR-F”;
“60227 IEC 52” by “H03 VV-F or
H03
VVH2-F”;
“60227 IEC 53” by “H05 VV-F or
H05
VVH2-F2”.
In Table 3B, replace the first four lines by the
following:
Up to and including 6 |
following:
Up to and including 6 |
0,75
a)
|
Over 6 up to and including 10| (0,75)
b)
1,0 |
Over 10 up to and including 16| (1,0)
c)
1,5 |
In the conditions applicable to Table 3B delete the
words “in some countries” in condition
words “in some countries” in condition
a)
.
In NOTE 1, applicable to Table 3B, delete the
second sentence.
second sentence.
Considered. N/A
3.3.4
In Table 3D, delete the fourth line: conductor sizes
for 10 to 13 A, and replace with the following:
Over 10 up to and including 16 | 1,5 to 2,5 | 1,5 to
4
for 10 to 13 A, and replace with the following:
Over 10 up to and including 16 | 1,5 to 2,5 | 1,5 to
4
|
Delete the fifth line: conductor sizes for 13 to 16 A
Class III equipment. Unit is
not intended for direct
connection to a mains supply.
not intended for direct
connection to a mains supply.
N/A
4.3.13.6
(A1:2010)
Replace the existing NOTE by the following:
NOTE Z1 Attention is drawn to:
1999/519/EC: Council Recommendation on the
limitation of exposure of the general public to
electromagnetic fields 0 Hz to 300 GHz, and
2006/25/EC: Directive on the minimum health and
safety requirements regarding the exposure of workers
to risks arising from physical agents (artifical optical
radiation).
1999/519/EC: Council Recommendation on the
limitation of exposure of the general public to
electromagnetic fields 0 Hz to 300 GHz, and
2006/25/EC: Directive on the minimum health and
safety requirements regarding the exposure of workers
to risks arising from physical agents (artifical optical
radiation).
Considered. N/A
Standards taking into account mentioned
Recommendation and Directive which demonstrate
compliance with the applicable EU Directive are
indicated in the OJEC.
Recommendation and Directive which demonstrate
compliance with the applicable EU Directive are
indicated in the OJEC.
Considered. N/A
Page 4 of 11
Report No.: 152949
IEC60950_1B - ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
IEC 60950-1, GROUP DIFFERENCES (CENELEC common modifications EN)
Clause
Requirement + Test
Result - Remark
Verdict
Annex H
Replace the last paragraph of this annex by:
At any point 10 cm from the surface of the
OPERATOR ACCESS AREA, the dose rate shall
not exceed 1 μSv/h (0,1 mR/h) (see NOTE).
Account is taken of the background level.
Replace the notes as follows:
At any point 10 cm from the surface of the
OPERATOR ACCESS AREA, the dose rate shall
not exceed 1 μSv/h (0,1 mR/h) (see NOTE).
Account is taken of the background level.
Replace the notes as follows:
NOTE These values appear in Directive 96/29/Euratom.
Delete NOTE 2.
The unit does not emit X-ray
radiation.
radiation.
N/A
Bibliography Additional
EN
standards.
⎯
ZA
NORMATIVE REFERENCES TO INTERNATIONAL PUBLICATIONS WITH
THEIR CORRESPONDING EUROPEAN PUBLICATIONS
THEIR CORRESPONDING EUROPEAN PUBLICATIONS
⎯
ZB ANNEX (normative)
SPECIAL NATIONAL CONDITIONS (EN)
Clause
Requirement + Test
Result - Remark
Verdict
1.2.4.1
In Denmark, certain types of Class I appliances
(see 3.2.1.1) may be provided with a plug not
establishing earthing conditions when inserted
into Danish socket-outlets.
(see 3.2.1.1) may be provided with a plug not
establishing earthing conditions when inserted
into Danish socket-outlets.
Class III equipment. Unit is
not intended for direct
connection to a mains supply.
not intended for direct
connection to a mains supply.
N/A
1.2.13.14
In Norway and Sweden, for requirements see
1.7.2.1 and 7.3 of this annex.
1.7.2.1 and 7.3 of this annex.
N/A
1.5.7.1
In Finland, Norway and Sweden, resistors
bridging
bridging
BASIC INSULATION
in
CLASS I PLUGGABLE
EQUIPMENT TYPE A
must comply with the
requirements in 1.5.7.1. In addition when a single
resistor is used, the resistor must withstand the
resistor test in 1.5.7.2.
resistor is used, the resistor must withstand the
resistor test in 1.5.7.2.
N/A
1.5.8
In Norway, due to the IT power system used (see
annex V, Figure V.7), capacitors are required to
be rated for the applicable line-to-line voltage
(230 V).
annex V, Figure V.7), capacitors are required to
be rated for the applicable line-to-line voltage
(230 V).
Class III equipment. Unit is
not intended for direct
connection to a mains supply.
not intended for direct
connection to a mains supply.
P
1.5.9.4
In Finland, Norway and Sweden, the third
dashed sentence is applicable only to equipment
as defined in 6.1.2.2 of this annex.
dashed sentence is applicable only to equipment
as defined in 6.1.2.2 of this annex.
N/A
Page 5 of 11
Report No.: 152949
IEC60950_1B - ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
ZB ANNEX (normative)
SPECIAL NATIONAL CONDITIONS (EN)
Clause
Requirement + Test
Result - Remark
Verdict
1.7.2.1
In Finland, Norway and Sweden, CLASS I
PLUGGABLE EQUIPMENT TYPE A intended for
connection to other equipment or a network shall,
if safety relies on connection to protective earth or
if surge suppressors are connected between the
network terminals and accessible parts, have a
marking stating that the equipment must be
connected to an earthed mains socket-outlet.
The marking text in the applicable countries shall
be as follows:
In Finland: "Laite on liitettävä suojakoskettimilla
varustettuun pistorasiaan"
In Norway: “Apparatet må tilkoples jordet
stikkontakt”
In Sweden: “Apparaten skall anslutas till jordat
uttag”
In Norway and Sweden, the screen of the cable
distribution system is normally not earthed at the
entrance of the building and there is normally no
equipotential bonding system within the building.
Therefore the protective earthing of the building
installation need to be isolated from the screen of
a cable distribution system.
It is however accepted to provide the insulation
external to the equipment by an adapter or an
interconnection cable with galvanic isolator, which
may be provided by e.g. a retailer.
The user manual shall then have the following or
similar information in Norwegian and Swedish
language respectively, depending on in what
country the equipment is intended to be used in:
“Equipment connected to the protective earthing
of the building installation through the mains
connection or through other equipment with a
connection to protective earthing – and to a cable
distribution system using coaxial cable, may in
some circumstances create a fire hazard.
Connection to a cable distribution system has
therefore to be provided through a device
providing electrical isolation below a certain
frequency range (galvanic isolator, see EN
60728-11).”
PLUGGABLE EQUIPMENT TYPE A intended for
connection to other equipment or a network shall,
if safety relies on connection to protective earth or
if surge suppressors are connected between the
network terminals and accessible parts, have a
marking stating that the equipment must be
connected to an earthed mains socket-outlet.
The marking text in the applicable countries shall
be as follows:
In Finland: "Laite on liitettävä suojakoskettimilla
varustettuun pistorasiaan"
In Norway: “Apparatet må tilkoples jordet
stikkontakt”
In Sweden: “Apparaten skall anslutas till jordat
uttag”
In Norway and Sweden, the screen of the cable
distribution system is normally not earthed at the
entrance of the building and there is normally no
equipotential bonding system within the building.
Therefore the protective earthing of the building
installation need to be isolated from the screen of
a cable distribution system.
It is however accepted to provide the insulation
external to the equipment by an adapter or an
interconnection cable with galvanic isolator, which
may be provided by e.g. a retailer.
The user manual shall then have the following or
similar information in Norwegian and Swedish
language respectively, depending on in what
country the equipment is intended to be used in:
“Equipment connected to the protective earthing
of the building installation through the mains
connection or through other equipment with a
connection to protective earthing – and to a cable
distribution system using coaxial cable, may in
some circumstances create a fire hazard.
Connection to a cable distribution system has
therefore to be provided through a device
providing electrical isolation below a certain
frequency range (galvanic isolator, see EN
60728-11).”
Class III equipment. Unit is
not intended for direct
connection to a mains supply.
not intended for direct
connection to a mains supply.
N/A
Page 6 of 11
Report No.: 152949
IEC60950_1B - ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
ZB ANNEX (normative)
SPECIAL NATIONAL CONDITIONS (EN)
Clause
Requirement + Test
Result - Remark
Verdict
NOTE In Norway, due to regulation for installations of cable
distribution systems, and in Sweden, a galvanic isolator shall
provide electrical insulation below 5 MHz. The insulation shall
withstand a dielectric strength of 1,5 kV r.m.s., 50 Hz or 60 Hz,
for 1 min.
distribution systems, and in Sweden, a galvanic isolator shall
provide electrical insulation below 5 MHz. The insulation shall
withstand a dielectric strength of 1,5 kV r.m.s., 50 Hz or 60 Hz,
for 1 min.
Translation to Norwegian (the Swedish text will
also be accepted in Norway):
“Utstyr som er koplet til beskyttelsesjord via
nettplugg og/eller via annet jordtilkoplet
utstyr – og er tilkoplet et kabel-TV nett, kan
forårsake brannfare. For å unngå dette skal det
ved tilkopling av utstyret til kabel-TV nettet
installeres en galvanisk isolator mellom utstyret
og kabel- TV nettet.”
Translation to Swedish:
”Utrustning som är kopplad till skyddsjord via
jordat vägguttag och/eller via annan
utrustning och samtidigt är kopplad till kabel-TV
nät kan i vissa fall medfőra risk főr
brand. Főr att undvika detta skall vid anslutning
av utrustningen till kabel-TV nät
galvanisk isolator finnas mellan utrustningen och
kabel-TV nätet.”
also be accepted in Norway):
“Utstyr som er koplet til beskyttelsesjord via
nettplugg og/eller via annet jordtilkoplet
utstyr – og er tilkoplet et kabel-TV nett, kan
forårsake brannfare. For å unngå dette skal det
ved tilkopling av utstyret til kabel-TV nettet
installeres en galvanisk isolator mellom utstyret
og kabel- TV nettet.”
Translation to Swedish:
”Utrustning som är kopplad till skyddsjord via
jordat vägguttag och/eller via annan
utrustning och samtidigt är kopplad till kabel-TV
nät kan i vissa fall medfőra risk főr
brand. Főr att undvika detta skall vid anslutning
av utrustningen till kabel-TV nät
galvanisk isolator finnas mellan utrustningen och
kabel-TV nätet.”
1.7.5
In Denmark, socket-outlets for providing power to
other equipment shall be in accordance with the
Heavy Current Regulations, Section 107-2-D1,
Standard Sheet DK 1-3a, DK 1-5a or DK 1-7a,
when used on Class I equipment. For
STATIONARY EQUIPMENT the socket-outlet
shall be in accordance with Standard Sheet DK 1-
1b or DK 1-5a.
For
other equipment shall be in accordance with the
Heavy Current Regulations, Section 107-2-D1,
Standard Sheet DK 1-3a, DK 1-5a or DK 1-7a,
when used on Class I equipment. For
STATIONARY EQUIPMENT the socket-outlet
shall be in accordance with Standard Sheet DK 1-
1b or DK 1-5a.
For
CLASS II EQUIPMENT
the socket outlet shall be
in accordance with Standard Sheet DKA 1-4a.
There are no socket outlets
providing power to other
appliances.
providing power to other
appliances.
N/A
2.2.4
In Norway, for requirements see 1.7.2.1, 6.1.2.1
and 6.1.2.2 of this annex.
and 6.1.2.2 of this annex.
No TNV circuits.
N/A
2.3.2
In Finland, Norway and Sweden there are
additional requirements for the insulation. See
6.1.2.1 and 6.1.2.2 of this annex.
additional requirements for the insulation. See
6.1.2.1 and 6.1.2.2 of this annex.
No TNV circuits.
N/A
2.3.4
In Norway, for requirements see 1.7.2.1, 6.1.2.1
and 6.1.2.2 of this annex.
and 6.1.2.2 of this annex.
No TNV circuits.
N/A
2.6.3.3
In the United Kingdom, the current rating of the
circuit shall be taken as 13 A, not 16 A.
circuit shall be taken as 13 A, not 16 A.
Class III equipment. Unit is
not intended for direct
connection to a mains supply.
not intended for direct
connection to a mains supply.
N/A
Click on the first or last page to see other RADIAL (serv.man5) service manuals if exist.