DOWNLOAD JBL RADIAL (serv.man5) Service Manual ↓ Size: 1.04 MB | Pages: 102 in PDF or view online for FREE

Model
RADIAL (serv.man5)
Pages
102
Size
1.04 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
radial-sm5.pdf
Date

JBL RADIAL (serv.man5) EMC - CB Certificate ▷ View online

   SI 60950:2000
  
Page 1 of 1
 
Report No. 152949 
 
SI 60950:2000 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
ATTACHMENT:  NATIONAL DIFFERENCES – ISRAEL 
Test results according to SI 60950:2000 
1.7.0 
Marking and Instructions 
 
The package of the equipment shall be marked in 
Hebrew, and shall include: 
- The name of the product, 
- The name of the manufacturer, 
- The country of production, 
- The name and the address of the importer. 
 
The marking shall be on a rectangular label (of at 
least 52mm x 24mm). The letters height should be 
at least 2mm. The color of the label shall be in 
contrast to the color of the package. 
Must be considered before 
marketing in Israel. 
 
 
N/A 
1.7.12 Language 
 
All instructions and warnings concerning safety 
should be in the Hebrew language as well. 
Must be considered before 
marketing in Israel. 
 
N/A 
2.101 EMC 
 
The equipment shall comply with SI 961 part 6 
(CISPR 22 + 24). 
Must be considered before 
marketing in Israel. 
 
   
N/A 
3.2.1.1 
Connection to an a.c. mains supply 
 
Additional note: 
In Israel the mains supply plug shall comply with 
Israeli standard SI 32. 
Class III equipment. 
N/A
 
 
 
IEC 60950 3rd Ed., 1999 
- Page 1 of 14 - 
 
 
 
Report No.  152949 
 
ATTACHMENT: NATIONAL DIFFERENCES – JAPAN
 
Test results according to ONLINE CB BULLETIN (Last modified date of 2007-09-10)
 
 
 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
1.2 
Addition:
 
Add the following terms. 
Equipment, Class 0I  
1.2.4.101 
Material, VTM    
1.2.12.101 
Considered. 
N/A 
1.2.4.101 
Addition:
 
CLASS 0I EQUIPMENT: Equipment where protection 
against electric shock is achieved by: 
a) using BASIC INSULATION, and 
b) providing a means of connecting to the protective 
earthing conductor in the building wiring those 
conductive parts that are otherwise capable of 
assuming HAZARDOUS VOLTAGES if the BASIC 
INSULATION fails, and 
c) using a supply cord without earthing conductor and 
a plug without earthing wire although the equipment 
has externally an earth terminal or a lead wire for 
earthing. 
Equipment provided with a cord set having a two-pin 
type plug with a lead wire for earthing is also regarded 
as Class 0I. 
NOTE – Class 0I equipment may have a part 
constructed with Double Insulation or Reinforced 
Insulation as well as an operating part as SELV circuit. 
Not class 0I equipment. 
N/A 
1.2.12.1 
Replacement:
 
FLAMMABILITY CLASSIFICATION OF MATERIALS: 
The recognition of the burning behaviour of materials 
and their ability to extinguish if ignited. Materials are 
classified as in 1.2.12.2 to 1.2.12.9, and 1.2.12.101 
when tested in accordance with annex A. 
NOTE 1 - When applying the requirements in this 
standard, HF-1 CLASS FOAMED MATERIALS are 
regarded as better than those of CLASS HF-2, and 
HF-2 better than HBF. 
NOTE 2 - Similarly, other MATERIALS, including rigid 
(engineering structural) foam of CLASSES 5V or V-0 
are regarded as better than those of CLASS V-1, V-1 
better than V-2, and V-2 better than HB. 
NOTE 3 - Similarly, for thin MATERIALS, VTM-0 Class 
materials are regarded as better than those of VTM-1 
Class, and VTM-1 better than VTM-2. 
All materials have suitable 
flammability properties; 
see appended table 1.5.1 
in main test report. 
IEC 60950 3rd Ed., 1999 
- Page 2 of 14 - 
 
 
 
Report No.  152949 
 
 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
1.2.12.101 
Addition:
 
VTM CLASS MATERIAL: Thin MATERIALS fulfil the 
specified conditions during the test of clause A.101 
applied for materials that the test and evaluation of 
clauses A.6 to A.10 is difficult to enforce. Materials are 
classified to three classifications as VTM-0, VTM-1 and 
VTM-2 according to the conditions after the removal of 
the test flame. 
Considered. 
N/A 
1.7.101 
Addition:
 
Marking for CLASS 0I EQUIPMENT 
For CLASS 0I EQUIPMENT, the following instruction 
shall be indicated on the visible place of the mains plug 
or the main body: 
“Provide an earthing connection” 
Moreover, for CLASS 0I EQUIPMENT, the following 
instruction shall be indicated on the visible place of the 
main body or written in the operating instructions: 
“Provide an earthing connection before the mains plug 
is connected to the mains. And, when disconnecting 
the earthing connection, be sure to disconnect after 
pulling out the mains plug from the mains.” 
Not Class 0I equipment.  
N/A 
2.1.1.1 
Replacement: 
Replace “IEC 60083” to “IEC 60083 or JIS C 8303” in 
2.1.1.1 b). 
Considered. 
2.6.3.1 
Addition:
 
Add the following after 1st paragraph. 
This also applies to the conductor of lead wire for 
protective earthing of CLASS 0I EQUIPMENT. 
Class III equipment. 
 
N/A 
2.6.4.1 
Replacement: 
Replace 2nd sentence in 1st paragraph. 
For CLASS I EQUIPMENT with a DETACHABLE 
POWER SUPPLY CORD, the earthing terminal in the 
appliance inlet is regarded as the main protective 
earthing terminal. 
Class III equipment. 
 
N/A 
2.6.5.4 
Replacement: 
Replace 1st sentence. 
Protective earthing connections of CLASS I 
EQUIPMENT shall make earlier and break later than 
the supply connections in each of the following: 
Class III equipment. 
 
N/A 
IEC 60950 3rd Ed., 1999 
- Page 3 of 14 - 
 
 
 
Report No.  152949 
 
 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
2.6.101 
Addition:
 
Earthing of CLASS 0I EQUIPMENT 
Plugs with a lead wire for earthing shall not be used for 
equipment having a rated voltage exceeding 150V. 
For plugs with a lead wire for earthing, the lead wire 
shall not be earthed by a clip. 
CLASS 0I EQUIPMENT shall be provided with an 
earthing terminal or lead wire for earthing in the 
external where easily visible. 
Class III equipment. 
 
N/A 
3.2.5 
Delete 1) in Table 3B. 
Deleted. 
N/A 
4.2.8 
Addition:
 
Add the following informative remark after the last 
sentence. 
Remark - IEC 61965 is also applicable instead of IEC 
60065. 
Added. 
N/A 
4.5.1 
Addition: 
Add the following to suffix 5) as specified in 
“Conditions applicable to Table 4A, Parts 1 and 2”. 
 
With regard to Table 4A, insulating materials 
complying with Japanese requirements (see 
Attachment below) are also acceptable.  
 
Add a suffix 7) in “Conditions applicable to Table 4A, 
Parts 1 and 2”. 
In the right column of Table 4A, Part 1, add suffix 7) to 
“50” (K), corresponding to “- without T – marking” in the 
left column so as to become “50 7)”. 
 
Add 7) to Table 4A, Part 2 as follows. 
 
7) This value shall apply only to wiring or cords 
complying with relevant IEC standards. Others shall 
comply with Japanese requirements (see Attachment 
below). 
 
Considered. 
Attachment 
 
The insulating materials shall not be exposed to the temperature exceeding the values when the 
appliances is operated at rated voltage and normal operating condition. 
These values may be increased by; 
8 degrees for Duty 2 appliance, and 
16 degrees for Duty 3 appliance. 
In order to classify the appliances, following assumptions are to be used. 
Duty 1 appliances: considered to be connected to supply mains throughout the years such as 
refrigerators 
Duty 2 appliances: considered to be connected to be in between Duty 1 and Duty 3 such as room 
heaters 
Duty 3 appliances: considered to be connected to supply mains when it is operated for rather short 
time such as portable coffee mill. 
 
Permissible temperature limits of insulating materials 
Page of 102