JBL RADIAL (serv.man5) EMC - CB Certificate ▷ View online

IEC 60950-1 (ed.2) 
 
- Page 2 of 7 - 
 
   
 
Report No.   152949 
 
1.7.1 
Special marking format for equipment intended 
for use on a supply system with an earthed 
neutral and more than one phase conductor.  
Class III equipment. 
N/A 
1.7.1 
Equipment voltage rating not higher than rating of 
the plug except under special conditions. 
Class III equipment. 
N/A 
1.7.6 
Fuse replacement marking for operator 
accessible fuses. 
Class III equipment 
N/A 
1.7.7 
Identification of terminal connection of the 
equipment earthing conductor. 
Class III equipment. 
N/A 
1.7.7 
Connectors and field wiring terminals for external 
Class 2 or Class 3 circuits provided with marking 
indicating minimum Class of wiring to be used. 
Class III equipment. 
N/A 
1.7.7 
Marking located adjacent to terminals and visible 
during wiring. 
Class III equipment. 
N/A 
2.1.1.1 
Bare TNV conductive parts protected by a cover 
are exempt if instructions include directions for 
disconnection of TNV prior to removal of the 
cover. 
No TNV circuitry. 
 
N/A 
2.3.1.b 
Other telecommunication signaling systems than 
described in 2.3.1(b) are subject to M.4. 
No TNV circuitry. 
 
N/A 
2.3.1.b 
For TNV-2 and TNV-3 circuits with other than 
ringing signals and with voltages exceeding 42.4 
Vp or 60 V d.c., the max. current limit through a 
resistor ≥ 2000 Ohm with loads disconnected is 
7.1 mA peak or 30 mA d.c. under normal 
conditions 
No TNV circuitry. 
 
N/A 
2.3.1.b 
Limits for measurements across 5000 Ohm 
resistor in the event of a single fault are replaced 
after 200 ms with the limits of M.3.1.4. 
No TNV circuitry. 
 
N/A 
2.3.2.1 
For a single fault, the limits of 2.2.3 apply to 
SELV circuits and accessible conductive parts. 
No TNV circuitry. 
 
N/A 
2.3.2.4 
Enamel coating on signal transformer winding 
wire allowed as an alternative to Basic insulation 
in specific telecommunication applications if 
subject to special construction requirements and 
testing. 
No TNV circuitry. 
 
N/A 
2.5 
Where a fuse is used to provide Class 2, Limited 
Power Source, or TNV current limiting, it shall not 
be operator-accessible unless it is not 
interchangeable. 
No fuse in the equipment. 
N/A 
2.6 
Equipment having receptacles for output a.c. 
power connectors generated from an internal 
separately derived source have the earthed 
(grounded) circuit conductor suitably bonded to 
earth. 
Class III equipment. 
N/A 
2.6.3.3 
For Pluggable Equipment Type A, if a) b) or c) 
are not applicable, the current rating of the circuit 
is taken as 20 A. 
Class III equipment. 
N/A 
2.6.3.4 
Capacity of connection between earthing terminal 
and parts required to be earthed subject to 
special conditions based on the current rating of 
the circuit. 
Class III equipment. 
N/A 
2.6.4.1 
Field wiring terminals for earthing conductors 
suitable for wire sizes (gauge) used in US.  
Class III equipment. 
N/A 
2.7.1 
Data for selection of special external branch 
circuit overcurrent devices marked on the 
equipment. 
Class III equipment. 
N/A 
2.7.1 
Standard supply outlets protected by overcurrent 
device in accordance with the NEC 
No standard supply outlets.  
N/A 
IEC 60950-1 (ed.2) 
 
- Page 3 of 7 - 
 
   
 
Report No.   152949 
 
2.7.1 
Overcurrent protection for individual transformers 
that distribute power to other units over branch 
circuit wiring. 
No transformers. 
N/A 
2.7.1 Additional 
requirements 
for 
overcurrent 
protection apply to equipment provided with 
panelboards. 
Equipment is not provided with 
panel boards. 
N/A 
2.7.1 Non-motor-operated 
equipment 
requiring 
special 
overcurrent protective device marked with device 
rating. 
Class III equipment. 
N/A 
2.10.5.12  Multi-layer winding wire subject to UL component 
wire requirements in addition to 2.10.5.12 and 
Annex U. 
No such wire used. 
N/A 
3.1.1 
Permissible combinations of internal 
wiring/external cable sizes for overcurrent & short 
circuit protection. 
Class III equipment. 
N/A 
3.1.1 
All interconnecting cables protected against 
overcurrent and short circuit. 
Class III equipment. 
N/A 
3.2 
Wiring methods (terminals, leads etc.) used for 
the connection of the equipment to the mains 
shall be in accordance with the NEC/CEC. 
Class III equipment. Unit is not 
intended for direct connection to 
a mains supply. 
N/A 
3.2.1 
Permitted use for flexible cords and plugs. 
Class III equipment. 
N/A 
3.2.1 
Flexible cords provided with attachment plug 
rated 125% of equipment current rating. 
Class III equipment. 
N/A 
3.2.1 
Any Class II equipment provided with 15 or 20 A 
standard supply outlets, Edison-base 
lampholders or single pole disconnect device 
provided with a polarized type attachment plug. 
Equipment is not class II. 
N/A 
3.2.1.2 
Equipment intended for connection to DC mains 
supply power systems complies with special 
wiring requirements 
Class III equipment. Equipment 
not for connection to DC mains. 
N/A 
3.2.1.2 
Equipment with one pole of the DC mains supply 
connected to both the equipment mains input 
terminal and the main protective earthing 
terminal provided with special instructions and 
construction provisions for earthing 
Class III equipment. Equipment 
not for connection to DC mains. 
N/A 
3.2.1.2 
Equipment with means for connecting supply to 
earthing electrode conductor has no switches or 
protective devices between supply connection 
and earthing electrode connection. 
Class III equipment. Equipment 
not for connection to DC mains. 
N/A 
3.2.1.2 
Markings and instructions for equipment with 
provisions to connect earthed conductor of a DC 
supply circuit to the equipment earthing 
conductor 
Class III equipment. Equipment 
not for connection to DC mains. 
N/A 
3.2.1.2 
Special markings and instructions for equipment 
with earthed conductor of a DC supply circuit 
connected to the equipment earthing conductor 
Class III equipment. Equipment 
not for connection to DC mains. 
N/A 
3.2.1.2 
Terminals and leads provided for permanent 
connection of DC powered equipment to supply 
marked to indicate polarity if reverse polarity may 
result in a hazard. 
Class III equipment. Equipment 
not for connection to DC mains. 
N/A 
3.2.3 
Permanently connected equipment has provision 
for connecting and securing a field wiring system 
(i.e. conduit, or leads etc.) per the NEC  
Class III equipment.  
N/A 
3.2.3 
Permanently connected equipment may have 
terminals or leads not smaller than No. 18 AWG 
(0.82 mm²) and not less than 150 mm in length 
for connection of field installed wiring. 
Class III equipment. Equipment 
is not intended for permanent 
connection to the mains. 
N/A 
IEC 60950-1 (ed.2) 
 
- Page 4 of 7 - 
 
   
 
Report No.   152949 
 
3.2.3 
If supply wires exceed 60 °C, marking indicates 
use of 75 °C or 90 °C wiring for supply 
connection as appropriate. 
Class III equipment. 
N/A 
3.2.3 
Equipment compatible with suitable trade sizes of 
conduits and cables. 
Class III equipment. 
N/A 
3.2.5 
Length of power supply cord limited to between 
1.5 and 4.5 m unless shorter length used when 
intended for a special installation. 
Class III equipment. 
N/A 
3.2.5 
Conductors in power supply cords sized per 
NEC. 
Class III equipment. 
N/A 
3.2.5 
Power supply cords and cord sets incorporate 
flexible cords suitable for the particular 
application. 
Class III equipment. 
N/A 
3.2.6 
Strain relief provided for non-detachable 
interconnecting cables not supplied by a limited 
power source. 
Class III equipment. 
N/A 
3.2.9 
Adequate wire bending space and volume of field 
wiring compartment required to properly make 
the field connections. 
Class III equipment. Not 
permanently connected to the 
mains. 
N/A 
3.2.9 
Equipment solely for installation in Restricted 
Access Locations using low voltage d.c. systems 
may not need provision for connecting and 
securing a field wiring system when wiring is 
protected from abuse. 
Not RAL equipment. 
N/A 
3.3 
Field wiring terminals provided for 
interconnection of units for other then LPS or 
Class 2 circuits also comply with 3.3. 
Class III equipment. Unit is not 
intended for direct connection to 
a mains supply. 
N/A
 
3.3 
Interconnection of units by LPS or Class 2 
conductors may have field wiring connectors 
other than specified in 3.3 if wiring is reliably 
separated 
Class III equipment. 
N/A 
3.3.1 
Terminals for the connection of neutral conductor 
identified by a distinctive white marking or other 
equally effective means. 
Class III equipment. 
N/A 
3.3.3 
Wire binding screws are not permitted to attach 
conductors larger than 10 AWG (5.3 mm2). 
Class III equipment. 
N/A
 
3.3.4 
Terminals accept US wire sizes (gauge) 
Class III equipment. Unit is not 
intended for direct connection to 
a mains supply. 
N/A 
3.3.4 
Terminals accept current-carrying conductors 
rated 125% of the equipment current rating. 
Class III equipment. Unit is not 
intended for direct connection to 
a mains supply. 
N/A 
3.3.6 
Field wiring terminals marked to indicate the 
material(s) of the conductor for the terminals 
used. 
Class III equipment. Unit is not 
intended for direct connection to 
a mains supply. 
N/A 
3.3.6 
Aluminum conductors not permitted for 
connection to terminal for equipment earthing 
conductor 
Class III equipment. Unit is not 
intended for direct connection to 
a mains supply. 
N/A 
3.3.6 
Field wiring connections made through the use of 
suitable pressure connectors (including set screw 
type), solder lugs or splices to flexible leads. 
Class III equipment. Unit is not 
intended for direct connection to 
a mains supply. 
N/A 
3.4.2 
Separate motor control device(s) required for 
cord-connected equipment rated more than 12 A, 
or with motor rated more than 1/3 hp or more 
than 120 V. 
No motors in the equipment. 
N/A 
3.4.8 
Vertically-mounted disconnect switches and 
circuit breakers are required to have the “on” 
position indicated by the handle in the up 
position. 
No disconnect switch in the 
equipment. 
N/A 
IEC 60950-1 (ed.2) 
 
- Page 5 of 7 - 
 
   
 
Report No.   152949 
 
3.4.11 
For computer room applications, equipment with 
battery systems capable of supplying 750 VA for 
five minutes are required to have a battery 
disconnect means that may be connected to the 
computer room remote power-off circuit. 
No battery in the equipment. 
N/A 
4.2.8.1 
Special opening restrictions for enclosures 
around CRTs with face dimension of 160 mm or 
more. 
No CRTs in the equipment. 
N/A 
4.2.9 
Compartment housing high-pressure lamp 
marked to indicate risk of explosion. 
No High-pressure lamp in the 
equipment. 
N/A 
4.2.11 
For equipment mounted on racks and provided 
with slide/rails allowing the equipment to slide 
away from the rack for installation and 
maintenance, additional construction, 
performance and marking requirements are 
applicable to determine the adequacy of the 
slide/rails 
Equipment is not provided with 
slide/rails. 
N/A 
4.3.2 
Loading test for equipment with handle(s) used to 
support more than 9 kg.  
The equipment has no handles.  
N/A 
4.3.6 
In addition to the IEC requirements, Direct Plug-
in Equipment complies with UL 1310.  
Equipment not for direct plug-in.  
N/A 
4.3.12 
The max. quantity of flammable liquid stored in 
equipment per ANSI/NFPA 30 (Table NAE.6) 
No flammable liquids within the 
equipment. 
N/A 
4.3.12 
Equipment using replenishable liquids marked to 
indicate type of liquid to be used. 
No liquids within the equipment. 
N/A 
4.3.13.2  Equipment that produces x-radiation and does 
not comply with 4.3.12 under all conditions of 
servicing marked to indicate the presence of 
radiation  
No laser components. LED is 
diffused type. 
N/A 
4.3.13.5  Requirements contained in the applicable 
national codes apply to lasers (21 CFR 1040). 
No laser components. LED is 
diffused type. 
N/A 
4.7 
Automated information storage equipment 
intended to contain more than 0.76 m³ of 
combustible media requires provision for 
automatic sprinklers or a gaseous agent 
extinguishing system. 
The equipment has no 
combustible area greater than 27 
cubic feet. 
N/A
 
4.7.3.1 
For computer room applications, enclosures with 
combustible material measuring greater than 0.9 
m2 or a single dimension greater than 1.8 m are 
required to have a flame spread rating of 50 or 
less. For other applications, enclosures with the 
same dimensions require a flame spread rating 
of 200 or less. 
The equipment has no 
combustible material greater 
than 0.93m² or single dimension 
greater than 1.8m. 
N/A
 
4.7.3.4 
Wire marked "VW-1" or "FT-1" considered 
equivalent. 
Considered. 