JBL RADIAL (serv.man5) EMC - CB Certificate ▷ View online
IEC 60950-1 (ed.2)
- Page 2 of 7 -
Report No. 152949
1.7.1
Special marking format for equipment intended
for use on a supply system with an earthed
neutral and more than one phase conductor.
for use on a supply system with an earthed
neutral and more than one phase conductor.
Class III equipment.
N/A
1.7.1
Equipment voltage rating not higher than rating of
the plug except under special conditions.
the plug except under special conditions.
Class III equipment.
N/A
1.7.6
Fuse replacement marking for operator
accessible fuses.
accessible fuses.
Class III equipment
N/A
1.7.7
Identification of terminal connection of the
equipment earthing conductor.
equipment earthing conductor.
Class III equipment.
N/A
1.7.7
Connectors and field wiring terminals for external
Class 2 or Class 3 circuits provided with marking
indicating minimum Class of wiring to be used.
Class 2 or Class 3 circuits provided with marking
indicating minimum Class of wiring to be used.
Class III equipment.
N/A
1.7.7
Marking located adjacent to terminals and visible
during wiring.
during wiring.
Class III equipment.
N/A
2.1.1.1
Bare TNV conductive parts protected by a cover
are exempt if instructions include directions for
disconnection of TNV prior to removal of the
cover.
are exempt if instructions include directions for
disconnection of TNV prior to removal of the
cover.
No TNV circuitry.
N/A
2.3.1.b
Other telecommunication signaling systems than
described in 2.3.1(b) are subject to M.4.
described in 2.3.1(b) are subject to M.4.
No TNV circuitry.
N/A
2.3.1.b
For TNV-2 and TNV-3 circuits with other than
ringing signals and with voltages exceeding 42.4
Vp or 60 V d.c., the max. current limit through a
resistor ≥ 2000 Ohm with loads disconnected is
7.1 mA peak or 30 mA d.c. under normal
conditions
ringing signals and with voltages exceeding 42.4
Vp or 60 V d.c., the max. current limit through a
resistor ≥ 2000 Ohm with loads disconnected is
7.1 mA peak or 30 mA d.c. under normal
conditions
No TNV circuitry.
N/A
2.3.1.b
Limits for measurements across 5000 Ohm
resistor in the event of a single fault are replaced
after 200 ms with the limits of M.3.1.4.
resistor in the event of a single fault are replaced
after 200 ms with the limits of M.3.1.4.
No TNV circuitry.
N/A
2.3.2.1
For a single fault, the limits of 2.2.3 apply to
SELV circuits and accessible conductive parts.
SELV circuits and accessible conductive parts.
No TNV circuitry.
N/A
2.3.2.4
Enamel coating on signal transformer winding
wire allowed as an alternative to Basic insulation
in specific telecommunication applications if
subject to special construction requirements and
testing.
wire allowed as an alternative to Basic insulation
in specific telecommunication applications if
subject to special construction requirements and
testing.
No TNV circuitry.
N/A
2.5
Where a fuse is used to provide Class 2, Limited
Power Source, or TNV current limiting, it shall not
be operator-accessible unless it is not
interchangeable.
Power Source, or TNV current limiting, it shall not
be operator-accessible unless it is not
interchangeable.
No fuse in the equipment.
N/A
2.6
Equipment having receptacles for output a.c.
power connectors generated from an internal
separately derived source have the earthed
(grounded) circuit conductor suitably bonded to
earth.
power connectors generated from an internal
separately derived source have the earthed
(grounded) circuit conductor suitably bonded to
earth.
Class III equipment.
N/A
2.6.3.3
For Pluggable Equipment Type A, if a) b) or c)
are not applicable, the current rating of the circuit
is taken as 20 A.
are not applicable, the current rating of the circuit
is taken as 20 A.
Class III equipment.
N/A
2.6.3.4
Capacity of connection between earthing terminal
and parts required to be earthed subject to
special conditions based on the current rating of
the circuit.
and parts required to be earthed subject to
special conditions based on the current rating of
the circuit.
Class III equipment.
N/A
2.6.4.1
Field wiring terminals for earthing conductors
suitable for wire sizes (gauge) used in US.
suitable for wire sizes (gauge) used in US.
Class III equipment.
N/A
2.7.1
Data for selection of special external branch
circuit overcurrent devices marked on the
equipment.
circuit overcurrent devices marked on the
equipment.
Class III equipment.
N/A
2.7.1
Standard supply outlets protected by overcurrent
device in accordance with the NEC
device in accordance with the NEC
No standard supply outlets.
N/A
IEC 60950-1 (ed.2)
- Page 3 of 7 -
Report No. 152949
2.7.1
Overcurrent protection for individual transformers
that distribute power to other units over branch
circuit wiring.
that distribute power to other units over branch
circuit wiring.
No transformers.
N/A
2.7.1 Additional
requirements
for
overcurrent
protection apply to equipment provided with
panelboards.
panelboards.
Equipment is not provided with
panel boards.
panel boards.
N/A
2.7.1 Non-motor-operated
equipment
requiring
special
overcurrent protective device marked with device
rating.
rating.
Class III equipment.
N/A
2.10.5.12 Multi-layer winding wire subject to UL component
wire requirements in addition to 2.10.5.12 and
Annex U.
Annex U.
No such wire used.
N/A
3.1.1
Permissible combinations of internal
wiring/external cable sizes for overcurrent & short
circuit protection.
wiring/external cable sizes for overcurrent & short
circuit protection.
Class III equipment.
N/A
3.1.1
All interconnecting cables protected against
overcurrent and short circuit.
overcurrent and short circuit.
Class III equipment.
N/A
3.2
Wiring methods (terminals, leads etc.) used for
the connection of the equipment to the mains
shall be in accordance with the NEC/CEC.
the connection of the equipment to the mains
shall be in accordance with the NEC/CEC.
Class III equipment. Unit is not
intended for direct connection to
a mains supply.
intended for direct connection to
a mains supply.
N/A
3.2.1
Permitted use for flexible cords and plugs.
Class III equipment.
N/A
3.2.1
Flexible cords provided with attachment plug
rated 125% of equipment current rating.
rated 125% of equipment current rating.
Class III equipment.
N/A
3.2.1
Any Class II equipment provided with 15 or 20 A
standard supply outlets, Edison-base
lampholders or single pole disconnect device
provided with a polarized type attachment plug.
standard supply outlets, Edison-base
lampholders or single pole disconnect device
provided with a polarized type attachment plug.
Equipment is not class II.
N/A
3.2.1.2
Equipment intended for connection to DC mains
supply power systems complies with special
wiring requirements
supply power systems complies with special
wiring requirements
Class III equipment. Equipment
not for connection to DC mains.
not for connection to DC mains.
N/A
3.2.1.2
Equipment with one pole of the DC mains supply
connected to both the equipment mains input
terminal and the main protective earthing
terminal provided with special instructions and
construction provisions for earthing
connected to both the equipment mains input
terminal and the main protective earthing
terminal provided with special instructions and
construction provisions for earthing
Class III equipment. Equipment
not for connection to DC mains.
not for connection to DC mains.
N/A
3.2.1.2
Equipment with means for connecting supply to
earthing electrode conductor has no switches or
protective devices between supply connection
and earthing electrode connection.
earthing electrode conductor has no switches or
protective devices between supply connection
and earthing electrode connection.
Class III equipment. Equipment
not for connection to DC mains.
not for connection to DC mains.
N/A
3.2.1.2
Markings and instructions for equipment with
provisions to connect earthed conductor of a DC
supply circuit to the equipment earthing
conductor
provisions to connect earthed conductor of a DC
supply circuit to the equipment earthing
conductor
Class III equipment. Equipment
not for connection to DC mains.
not for connection to DC mains.
N/A
3.2.1.2
Special markings and instructions for equipment
with earthed conductor of a DC supply circuit
connected to the equipment earthing conductor
with earthed conductor of a DC supply circuit
connected to the equipment earthing conductor
Class III equipment. Equipment
not for connection to DC mains.
not for connection to DC mains.
N/A
3.2.1.2
Terminals and leads provided for permanent
connection of DC powered equipment to supply
marked to indicate polarity if reverse polarity may
result in a hazard.
connection of DC powered equipment to supply
marked to indicate polarity if reverse polarity may
result in a hazard.
Class III equipment. Equipment
not for connection to DC mains.
not for connection to DC mains.
N/A
3.2.3
Permanently connected equipment has provision
for connecting and securing a field wiring system
(i.e. conduit, or leads etc.) per the NEC
for connecting and securing a field wiring system
(i.e. conduit, or leads etc.) per the NEC
Class III equipment.
N/A
3.2.3
Permanently connected equipment may have
terminals or leads not smaller than No. 18 AWG
(0.82 mm²) and not less than 150 mm in length
for connection of field installed wiring.
terminals or leads not smaller than No. 18 AWG
(0.82 mm²) and not less than 150 mm in length
for connection of field installed wiring.
Class III equipment. Equipment
is not intended for permanent
connection to the mains.
is not intended for permanent
connection to the mains.
N/A
IEC 60950-1 (ed.2)
- Page 4 of 7 -
Report No. 152949
3.2.3
If supply wires exceed 60 °C, marking indicates
use of 75 °C or 90 °C wiring for supply
connection as appropriate.
use of 75 °C or 90 °C wiring for supply
connection as appropriate.
Class III equipment.
N/A
3.2.3
Equipment compatible with suitable trade sizes of
conduits and cables.
conduits and cables.
Class III equipment.
N/A
3.2.5
Length of power supply cord limited to between
1.5 and 4.5 m unless shorter length used when
intended for a special installation.
1.5 and 4.5 m unless shorter length used when
intended for a special installation.
Class III equipment.
N/A
3.2.5
Conductors in power supply cords sized per
NEC.
NEC.
Class III equipment.
N/A
3.2.5
Power supply cords and cord sets incorporate
flexible cords suitable for the particular
application.
flexible cords suitable for the particular
application.
Class III equipment.
N/A
3.2.6
Strain relief provided for non-detachable
interconnecting cables not supplied by a limited
power source.
interconnecting cables not supplied by a limited
power source.
Class III equipment.
N/A
3.2.9
Adequate wire bending space and volume of field
wiring compartment required to properly make
the field connections.
wiring compartment required to properly make
the field connections.
Class III equipment. Not
permanently connected to the
mains.
permanently connected to the
mains.
N/A
3.2.9
Equipment solely for installation in Restricted
Access Locations using low voltage d.c. systems
may not need provision for connecting and
securing a field wiring system when wiring is
protected from abuse.
Access Locations using low voltage d.c. systems
may not need provision for connecting and
securing a field wiring system when wiring is
protected from abuse.
Not RAL equipment.
N/A
3.3
Field wiring terminals provided for
interconnection of units for other then LPS or
Class 2 circuits also comply with 3.3.
interconnection of units for other then LPS or
Class 2 circuits also comply with 3.3.
Class III equipment. Unit is not
intended for direct connection to
a mains supply.
intended for direct connection to
a mains supply.
N/A
3.3
Interconnection of units by LPS or Class 2
conductors may have field wiring connectors
other than specified in 3.3 if wiring is reliably
separated
conductors may have field wiring connectors
other than specified in 3.3 if wiring is reliably
separated
Class III equipment.
N/A
3.3.1
Terminals for the connection of neutral conductor
identified by a distinctive white marking or other
equally effective means.
identified by a distinctive white marking or other
equally effective means.
Class III equipment.
N/A
3.3.3
Wire binding screws are not permitted to attach
conductors larger than 10 AWG (5.3 mm2).
conductors larger than 10 AWG (5.3 mm2).
Class III equipment.
N/A
3.3.4
Terminals accept US wire sizes (gauge)
Class III equipment. Unit is not
intended for direct connection to
a mains supply.
intended for direct connection to
a mains supply.
N/A
3.3.4
Terminals accept current-carrying conductors
rated 125% of the equipment current rating.
rated 125% of the equipment current rating.
Class III equipment. Unit is not
intended for direct connection to
a mains supply.
intended for direct connection to
a mains supply.
N/A
3.3.6
Field wiring terminals marked to indicate the
material(s) of the conductor for the terminals
used.
material(s) of the conductor for the terminals
used.
Class III equipment. Unit is not
intended for direct connection to
a mains supply.
intended for direct connection to
a mains supply.
N/A
3.3.6
Aluminum conductors not permitted for
connection to terminal for equipment earthing
conductor
connection to terminal for equipment earthing
conductor
Class III equipment. Unit is not
intended for direct connection to
a mains supply.
intended for direct connection to
a mains supply.
N/A
3.3.6
Field wiring connections made through the use of
suitable pressure connectors (including set screw
type), solder lugs or splices to flexible leads.
suitable pressure connectors (including set screw
type), solder lugs or splices to flexible leads.
Class III equipment. Unit is not
intended for direct connection to
a mains supply.
intended for direct connection to
a mains supply.
N/A
3.4.2
Separate motor control device(s) required for
cord-connected equipment rated more than 12 A,
or with motor rated more than 1/3 hp or more
than 120 V.
cord-connected equipment rated more than 12 A,
or with motor rated more than 1/3 hp or more
than 120 V.
No motors in the equipment.
N/A
3.4.8
Vertically-mounted disconnect switches and
circuit breakers are required to have the “on”
position indicated by the handle in the up
position.
circuit breakers are required to have the “on”
position indicated by the handle in the up
position.
No disconnect switch in the
equipment.
equipment.
N/A
IEC 60950-1 (ed.2)
- Page 5 of 7 -
Report No. 152949
3.4.11
For computer room applications, equipment with
battery systems capable of supplying 750 VA for
five minutes are required to have a battery
disconnect means that may be connected to the
computer room remote power-off circuit.
battery systems capable of supplying 750 VA for
five minutes are required to have a battery
disconnect means that may be connected to the
computer room remote power-off circuit.
No battery in the equipment.
N/A
4.2.8.1
Special opening restrictions for enclosures
around CRTs with face dimension of 160 mm or
more.
around CRTs with face dimension of 160 mm or
more.
No CRTs in the equipment.
N/A
4.2.9
Compartment housing high-pressure lamp
marked to indicate risk of explosion.
marked to indicate risk of explosion.
No High-pressure lamp in the
equipment.
equipment.
N/A
4.2.11
For equipment mounted on racks and provided
with slide/rails allowing the equipment to slide
away from the rack for installation and
maintenance, additional construction,
performance and marking requirements are
applicable to determine the adequacy of the
slide/rails
with slide/rails allowing the equipment to slide
away from the rack for installation and
maintenance, additional construction,
performance and marking requirements are
applicable to determine the adequacy of the
slide/rails
Equipment is not provided with
slide/rails.
slide/rails.
N/A
4.3.2
Loading test for equipment with handle(s) used to
support more than 9 kg.
support more than 9 kg.
The equipment has no handles.
N/A
4.3.6
In addition to the IEC requirements, Direct Plug-
in Equipment complies with UL 1310.
in Equipment complies with UL 1310.
Equipment not for direct plug-in.
N/A
4.3.12
The max. quantity of flammable liquid stored in
equipment per ANSI/NFPA 30 (Table NAE.6)
equipment per ANSI/NFPA 30 (Table NAE.6)
No flammable liquids within the
equipment.
equipment.
N/A
4.3.12
Equipment using replenishable liquids marked to
indicate type of liquid to be used.
indicate type of liquid to be used.
No liquids within the equipment.
N/A
4.3.13.2 Equipment that produces x-radiation and does
not comply with 4.3.12 under all conditions of
servicing marked to indicate the presence of
radiation
servicing marked to indicate the presence of
radiation
No laser components. LED is
diffused type.
diffused type.
N/A
4.3.13.5 Requirements contained in the applicable
national codes apply to lasers (21 CFR 1040).
No laser components. LED is
diffused type.
diffused type.
N/A
4.7
Automated information storage equipment
intended to contain more than 0.76 m³ of
combustible media requires provision for
automatic sprinklers or a gaseous agent
extinguishing system.
intended to contain more than 0.76 m³ of
combustible media requires provision for
automatic sprinklers or a gaseous agent
extinguishing system.
The equipment has no
combustible area greater than 27
cubic feet.
combustible area greater than 27
cubic feet.
N/A
4.7.3.1
For computer room applications, enclosures with
combustible material measuring greater than 0.9
m2 or a single dimension greater than 1.8 m are
required to have a flame spread rating of 50 or
less. For other applications, enclosures with the
same dimensions require a flame spread rating
of 200 or less.
combustible material measuring greater than 0.9
m2 or a single dimension greater than 1.8 m are
required to have a flame spread rating of 50 or
less. For other applications, enclosures with the
same dimensions require a flame spread rating
of 200 or less.
The equipment has no
combustible material greater
than 0.93m² or single dimension
greater than 1.8m.
combustible material greater
than 0.93m² or single dimension
greater than 1.8m.
N/A
4.7.3.4
Wire marked "VW-1" or "FT-1" considered
equivalent.
equivalent.
Considered.
P