Page 24 of 49 
Report No. 152949 
 
  
IEC 
60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60950_1B 
 
 
4.3.13.5 
Lasers (including laser diodes) and LEDs 
No laser components. LED is 
diffused type. 
N/A 
4.3.13.5.1 
Lasers (including laser laser diodes) 
 
N/A 
 Laser 
class 
 
........................................................... 
 
⎯ 
4.3.13.5.2  Light emitting diodes (LEDs) 
 
 
4.3.13.6 
Other types  .......................................................... : 
No other parts of radiation. 
N/A 
 
4.4 
Protection against hazardous moving parts 
N/A 
4.4.1 
General 
No moving parts. 
N/A 
4.4.2 
Protection in operator access areas  .................... : 
 
N/A 
 
Household and home/office document/media 
shredders 
 N/A 
4.4.3 
Protection in restricted access locations  ............. : 
 
N/A 
4.4.4 
Protection in service access areas 
 
N/A 
4.4.5 
Protection against moving fan blades 
 
N/A 
4.4.5.1 General 
 
N/A 
 
Not considered to cause pain or injury. 
a)………….: 
 N/A 
 
Is considered to cause pain, not injury. 
b) …………: 
 N/A 
 
Considered to cause injury.                   
c) …………:  
 N/A 
4.4.5.2 Protection 
for 
users 
 
N/A 
 
Use of symbol or 
warning ……………………………: 
 N/A 
4.4.5.3 
Protection for service persons 
 
N/A 
 
Use of symbol or 
warning ……………………………: 
 N/A 
 
4.5 Thermal 
requirements 
4.5.1 General 
 
4.5.2 
Temperature tests 
Refer to appended table 4.5. 
 
Normal load condition per Annex L ...................... : 
Refer to Test items 
particulars. 
⎯ 
4.5.3 
Temperature limits for materials 
(see appended table 4.5) 
 
Page 25 of 49 
Report No. 152949 
 
  
IEC 
60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60950_1B 
 
 
4.5.4 
Touch temperature limits 
External temperatures on 
equipment was not recorded, 
but found to meet 
temperature requimrents 
based off internal measured 
temperatures on 
components/materials. 
4.5.5 
Resistance to abnormal heat  ............................... : 
No thermoplastic parts 
carrying hazardous voltages. 
N/A 
 
4.6 Openings 
in 
enclosures 
N/A 
4.6.1 
Top and side openings 
No top and side openings. 
N/A 
 Dimensions 
(mm) 
 
................................................. 
 
⎯ 
4.6.2 
Bottoms of fire enclosures 
No bottom openings. 
N/A 
 
Construction of the bottomm, dimensions (mm)  .. : 
 
⎯ 
4.6.3 
Doors or covers in fire enclosures 
No doors or covers provided. 
N/A 
4.6.4 
Openings in transportable equipment 
The unit is not regarded as 
transportable equipment. 
N/A 
4.6.4.1 
Constructional design measures 
 
N/A 
 Dimensions 
(mm) 
 
................................................. 
 
⎯ 
4.6.4.2 
Evaluation measures for larger openings 
 
N/A 
4.6.4.3 
Use of metallized parts 
 
N/A 
4.6.5 
Adhesives for constructional purposes 
No barrier secured by 
adhesive inside enclosure. 
N/A 
 
Conditioning temperature (
°C), time (weeks) ....... :   
⎯ 
 
4.7 
Resistance to fire 
4.7.1 
Reducing the risk of ignition and spread of flame 
Equipment is class III 
equipment, powered from a 
LPS. 
 
Method 1, selection and application of components 
wiring and materials 
 P 
 
Method 2, application of all of simulated fault 
condition tests 
 N/A 
4.7.2 
Conditions for a fire enclosure 
Equipment is class III 
equipment, powered from a 
LPS. Fire enclosure is not 
considered necessary. 
N/A 
4.7.2.1 
Parts requiring a fire enclosure 
Refer to 4.7.2. 
N/A 
 
Page 26 of 49 
Report No. 152949 
 
  
IEC 
60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60950_1B 
 
 
4.7.2.2 
Parts not requiring a fire enclosure 
Equipment is class III 
powered from a LPS. 
Additionally, all components 
are mounted on  
V-1 or better material. 
4.7.3 Materials 
4.7.3.1 General 
Components 
and 
materials 
have adequate flammability 
classification. Refer to 
appended table 1.5.1. 
4.7.3.2 
Materials for fire enclosures 
Fire enclosure not required 
Refer to 4.7.2. 
N/A 
4.7.3.3 
Materials for components and other parts outside 
fire enclosures 
Fire enclosure not required. 
Enclosure is rated HB min. 
4.7.3.4 
Materials for components and other parts inside 
fire enclosures 
Fire enclosure not required. 
Refer to 4.7.2. 
N/A 
4.7.3.5 
Materials for air filter assemblies 
No air filters in the equipment.
N/A 
4.7.3.6 
Materials used in high-voltage components 
No parts exceeding 4kV. 
N/A 
 
ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS 
N/A 
5.1 
Touch current and protective conductor current 
N/A 
5.1.1 
General 
Class III equipment. Unit is 
not intended for direct 
connection to a mains supply. 
No test considered necessary
N/A 
5.1.2 
Configuration of equipment under test (EUT) 
 
N/A 
5.1.2.1 
Single connection to an a.c. mains supply 
 
N/A 
5.1.2.2 
Redundant multiple connections to an a.c. mains 
supply 
 N/A 
5.1.2.3 
Simultaneous multiple connections to an a.c. mains 
supply 
 N/A 
5.1.3 Test 
circuit 
 
N/A 
5.1.4 
Application of measuring instrument 
 
N/A 
5.1.5 Test 
procedure 
 
N/A 
5.1.6 Test 
measurements 
 
N/A 
 
Supply voltage (V)  ................................................ : 
 
⎯ 
 
Measured touch current (mA)  .............................. : 
 
⎯ 
 
Max. allowed touch current (mA)  ......................... : 
 
⎯ 
 
Measured protective conductor current (mA)  ...... : 
 
⎯ 
 
Page 27 of 49 
Report No. 152949 
 
  
IEC 
60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60950_1B 
 
 
 
Max. allowed protective conductor current (mA) .. : 
 
⎯ 
5.1.7 
Equipment with touch current exceeding 3,5 mA 
 
N/A 
5.1.7.1 General 
................................................................. 
 
N/A 
5.1.7.2 
Simultaneous multiple connections to the supply 
 
N/A 
5.1.8 
Touch currents to telecommunication networks and 
cable distribution systems and from 
telecommunication networks 
No TNV or CDS. 
N/A 
5.1.8.1 
Limitation of the touch current to a 
telecommunication network or to a cable 
distribution system 
 N/A 
 
Supply voltage (V)  ................................................ : 
 
⎯ 
 
Measured touch current (mA)  .............................. : 
 
⎯ 
 
Max. allowed touch current (mA)  ......................... : 
 
⎯ 
5.1.8.2 
Summation of touch currents from 
telecommunication networks 
 N/A 
 
a) EUT with earthed telecommunication ports  ..... : 
 
N/A 
 
b) EUT whose telecommunication ports have no 
reference to protective earth 
 N/A 
 
5.2 Electric 
strength 
N/A 
5.2.1 
General 
Functional insulation, no test 
required. 
N/A 
5.2.2 Test 
procedure 
 
 
N/A 
 
5.3 Abnormal 
operating 
and fault conditions 
5.3.1 
Protection against overload and abnormal 
operation 
(see appended table 5.3)  
5.3.2 
Motors 
There are no motors in the 
equipment.  
N/A 
5.3.3 
Transformers 
There are no safety 
transformers in the 
equipment. 
N/A 
5.3.4 
Functional insulation ............................................. : 
Complies with c), mounted on 
V-1 or better material. 
5.3.5 
Electromechanical components 
No electromechanical 
components in secondary 
circuits. 
N/A 
5.3.6 
Audio amplifiers in ITE  ......................................... : 
See summary of testing.  
N/A 
Page of 102
Display

Click on the first or last page to see other RADIAL (serv.man5) service manuals if exist.