JBL RADIAL (serv.man5) EMC - CB Certificate ▷ View online
Page 24 of 49
Report No. 152949
IEC
60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B
4.3.13.5
Lasers (including laser diodes) and LEDs
No laser components. LED is
diffused type.
diffused type.
N/A
4.3.13.5.1
Lasers (including laser laser diodes)
N/A
Laser
class
...........................................................
:
⎯
4.3.13.5.2 Light emitting diodes (LEDs)
4.3.13.6
Other types .......................................................... :
No other parts of radiation.
N/A
4.4
Protection against hazardous moving parts
N/A
4.4.1
General
No moving parts.
N/A
4.4.2
Protection in operator access areas .................... :
N/A
Household and home/office document/media
shredders
shredders
N/A
4.4.3
Protection in restricted access locations ............. :
N/A
4.4.4
Protection in service access areas
N/A
4.4.5
Protection against moving fan blades
N/A
4.4.5.1 General
N/A
Not considered to cause pain or injury.
a)………….:
a)………….:
N/A
Is considered to cause pain, not injury.
b) …………:
b) …………:
N/A
Considered to cause injury.
c) …………:
c) …………:
N/A
4.4.5.2 Protection
for
users
N/A
Use of symbol or
warning ……………………………:
warning ……………………………:
N/A
4.4.5.3
Protection for service persons
N/A
Use of symbol or
warning ……………………………:
warning ……………………………:
N/A
4.5 Thermal
requirements
P
4.5.1 General
P
4.5.2
Temperature tests
Refer to appended table 4.5.
P
Normal load condition per Annex L ...................... :
Refer to Test items
particulars.
particulars.
⎯
4.5.3
Temperature limits for materials
(see appended table 4.5)
P
Page 25 of 49
Report No. 152949
IEC
60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B
4.5.4
Touch temperature limits
External temperatures on
equipment was not recorded,
but found to meet
temperature requimrents
based off internal measured
temperatures on
components/materials.
equipment was not recorded,
but found to meet
temperature requimrents
based off internal measured
temperatures on
components/materials.
P
4.5.5
Resistance to abnormal heat ............................... :
No thermoplastic parts
carrying hazardous voltages.
carrying hazardous voltages.
N/A
4.6 Openings
in
enclosures
N/A
4.6.1
Top and side openings
No top and side openings.
N/A
Dimensions
(mm)
.................................................
:
⎯
4.6.2
Bottoms of fire enclosures
No bottom openings.
N/A
Construction of the bottomm, dimensions (mm) .. :
⎯
4.6.3
Doors or covers in fire enclosures
No doors or covers provided.
N/A
4.6.4
Openings in transportable equipment
The unit is not regarded as
transportable equipment.
transportable equipment.
N/A
4.6.4.1
Constructional design measures
N/A
Dimensions
(mm)
.................................................
:
⎯
4.6.4.2
Evaluation measures for larger openings
N/A
4.6.4.3
Use of metallized parts
N/A
4.6.5
Adhesives for constructional purposes
No barrier secured by
adhesive inside enclosure.
adhesive inside enclosure.
N/A
Conditioning temperature (
°C), time (weeks) ....... :
⎯
4.7
Resistance to fire
P
4.7.1
Reducing the risk of ignition and spread of flame
Equipment is class III
equipment, powered from a
LPS.
equipment, powered from a
LPS.
P
Method 1, selection and application of components
wiring and materials
wiring and materials
P
Method 2, application of all of simulated fault
condition tests
condition tests
N/A
4.7.2
Conditions for a fire enclosure
Equipment is class III
equipment, powered from a
LPS. Fire enclosure is not
considered necessary.
equipment, powered from a
LPS. Fire enclosure is not
considered necessary.
N/A
4.7.2.1
Parts requiring a fire enclosure
Refer to 4.7.2.
N/A
Page 26 of 49
Report No. 152949
IEC
60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B
4.7.2.2
Parts not requiring a fire enclosure
Equipment is class III
powered from a LPS.
Additionally, all components
are mounted on
V-1 or better material.
powered from a LPS.
Additionally, all components
are mounted on
V-1 or better material.
P
4.7.3 Materials
P
4.7.3.1 General
Components
and
materials
have adequate flammability
classification. Refer to
appended table 1.5.1.
classification. Refer to
appended table 1.5.1.
P
4.7.3.2
Materials for fire enclosures
Fire enclosure not required
Refer to 4.7.2.
Refer to 4.7.2.
N/A
4.7.3.3
Materials for components and other parts outside
fire enclosures
fire enclosures
Fire enclosure not required.
Enclosure is rated HB min.
Enclosure is rated HB min.
P
4.7.3.4
Materials for components and other parts inside
fire enclosures
fire enclosures
Fire enclosure not required.
Refer to 4.7.2.
Refer to 4.7.2.
N/A
4.7.3.5
Materials for air filter assemblies
No air filters in the equipment.
N/A
4.7.3.6
Materials used in high-voltage components
No parts exceeding 4kV.
N/A
5
ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS
N/A
5.1
Touch current and protective conductor current
N/A
5.1.1
General
Class III equipment. Unit is
not intended for direct
connection to a mains supply.
No test considered necessary
not intended for direct
connection to a mains supply.
No test considered necessary
N/A
5.1.2
Configuration of equipment under test (EUT)
N/A
5.1.2.1
Single connection to an a.c. mains supply
N/A
5.1.2.2
Redundant multiple connections to an a.c. mains
supply
supply
N/A
5.1.2.3
Simultaneous multiple connections to an a.c. mains
supply
supply
N/A
5.1.3 Test
circuit
N/A
5.1.4
Application of measuring instrument
N/A
5.1.5 Test
procedure
N/A
5.1.6 Test
measurements
N/A
Supply voltage (V) ................................................ :
⎯
Measured touch current (mA) .............................. :
⎯
Max. allowed touch current (mA) ......................... :
⎯
Measured protective conductor current (mA) ...... :
⎯
Page 27 of 49
Report No. 152949
IEC
60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B
Max. allowed protective conductor current (mA) .. :
⎯
5.1.7
Equipment with touch current exceeding 3,5 mA
N/A
5.1.7.1 General
.................................................................
:
N/A
5.1.7.2
Simultaneous multiple connections to the supply
N/A
5.1.8
Touch currents to telecommunication networks and
cable distribution systems and from
telecommunication networks
cable distribution systems and from
telecommunication networks
No TNV or CDS.
N/A
5.1.8.1
Limitation of the touch current to a
telecommunication network or to a cable
distribution system
telecommunication network or to a cable
distribution system
N/A
Supply voltage (V) ................................................ :
⎯
Measured touch current (mA) .............................. :
⎯
Max. allowed touch current (mA) ......................... :
⎯
5.1.8.2
Summation of touch currents from
telecommunication networks
telecommunication networks
N/A
a) EUT with earthed telecommunication ports ..... :
N/A
b) EUT whose telecommunication ports have no
reference to protective earth
reference to protective earth
N/A
5.2 Electric
strength
N/A
5.2.1
General
Functional insulation, no test
required.
required.
N/A
5.2.2 Test
procedure
N/A
5.3 Abnormal
operating
and fault conditions
P
5.3.1
Protection against overload and abnormal
operation
operation
(see appended table 5.3)
P
5.3.2
Motors
There are no motors in the
equipment.
equipment.
N/A
5.3.3
Transformers
There are no safety
transformers in the
equipment.
transformers in the
equipment.
N/A
5.3.4
Functional insulation ............................................. :
Complies with c), mounted on
V-1 or better material.
V-1 or better material.
P
5.3.5
Electromechanical components
No electromechanical
components in secondary
circuits.
components in secondary
circuits.
N/A
5.3.6
Audio amplifiers in ITE ......................................... :
See summary of testing.
N/A
Click on the first or last page to see other RADIAL (serv.man5) service manuals if exist.