Report No. 152949 
 
 
TRF No. IEC60950_1B 
 
 
 
Summary of compliance with National Differences 
All CENELEC members according to EN 60950-1:2006/A11:2009/A1:2010 
 
All CB members as listed in the IECEE Online Bulletin. 
Israel: Test results according to SI 60950:2000. 
Singapore: Consumer Protection Information Booklet, 2002 Edition, (Ver. 3). 
 
At the time of issuing this report, not all countries are listed for IEC 60950-1:2005 (ed.2).  Therefore this 
report includes National Differences for IEC 60950-1:2005 (ed.2), IEC 60950-1:2001 (ed.1) and  
IEC 60950:1999 (ed.3). 
 
All National differences listed in the CB Bulletin are covered by the Common Modifications, Special 
National Conditions, National Differences, and the National Requirements noted above except for the 
following countries which are documented in National Differences Appendixes attached to this report. 
 
China: Deviations to published 
IEC Documents. 
 
Japan: Deviations to published 
IEC Documents. 
 
Ukraine: Deviations to published 
IEC Documents. 
 
List from IEC 60950-1 (ed.1):  
 
Countries listed in the IECEE 
Online CB Bulletin as follows: 
Argentina (AR), Austria (AT), 
Australia (AU), Belgium (BE), 
Canada (CA), Switzerland (CH), 
China (CN), Germany (DE), 
Denmark (DK), Finland (FI), 
France (FR), United Kingdom 
(GB), Greece (GR), Hungary 
(HU), Israel (IL), India (IN), Italy 
(IT), Japan (JP), Kenya (KE), 
Korea (KR), Malaysia (MY), 
Netherlands (NL), Norway (NO), 
Poland (PL), Sweden (SE), 
Singapore (SG), Slovenia (SI), 
Slovakia (SK), United States 
(US). 
 
Australia (including New 
Zealand): Deviations to 
published IEC Documents. 
 
List from IEC 60950-1 (ed.2):  
 
Countries listed in the IECEE 
Online CB Bulletin as follows: 
Austria (AT), Switzerland (CH), 
Germany (DE), Denmark (DK), 
Spain (ES), Finland (FI), France 
(FR), United Kingdom (GB), 
Ireland (IE), Italy (IT), Japan 
(JP), Korea (KR), Netherlands 
(NL), Norway (NO), Poland (PL), 
Sweden (SE), Slovenia (SI). 
 
Canada: Deviations to published 
IEC Documents. 
 
Korea: Deviations to published 
IEC Documents. 
 
United States: Deviations to 
published IEC Documents. 
 
 
 
 
Page 5 of 49 
Report No. 152949 
 
 
TRF No. IEC60950_1B 
 
 
 
Copy of marking plate  
The artwork below may be only a draft. The use of certification marks on a product must be authorized 
by the respective NCBs that own these marks. 
(Additional requirements for markings. See 1.7 NOTE) 
 
 
 
 
 
Page 6 of 49 
Report No. 152949 
 
 
TRF No. IEC60950_1B 
 
 
 
Test item particulars ................................................... :  
Equipment mobility..................................................... : [X] movable     [] hand-held       [] transportable 
[] stationary  [] for building-in  [] direct plug-in 
Connection to the mains ............................................ : [] pluggable equipment   [] type A   [] type B 
[] permanent connection 
[] detachable power supply cord      
[] non-detachable power supply cord 
[X] not directly connected to the mains 
Operating condition .................................................... : [X] continuous 
Normal load: 
Max. Undistorted with sign wave signal was 4 W, 
reduced to 1/8th Max. with filtered pink noise per 
IEC/EN 60065 for maximum normal load. 
Refer to Summary of Testing. 
[] rated operating / resting time:  
Access location  ......................................................... : [X] operator accessible 
[] restricted access location 
Over voltage category (OVC)  ................................... : [X] OVC I     [] OVC II     [] OVC III     [] OVC IV 
[] other:  
Mains supply tolerance (%) or absolute mains 
supply values  ............................................................ :
 
N/A 
Tested for IT power systems  .................................... : [] Yes     [X] No 
IT testing, phase-phase voltage (V)  .......................... : N/A 
Class of equipment  ................................................... : [] Class I     [] Class II     [X] Class III      
[] Not classified 
Considered current rating of protective device as 
part of the building installlation (A)  ........................... :
 
N/A 
Pollution degree (PD)  ............................................... : [] PD 1     [X] PD 2     [] PD 3 
IP protection class  .................................................... : Minimum IP 20 (not evaluated for ingress of water) 
Altitude during operation (m)  .................................... : Normal Home and office <2000m 
Altitude of test laboratory (m)  .................................... : 10m, sea level 
Mass of equipment (kg)  ............................................ : 2.2 kg (representative of all models) 
Dimension: 30.5mm diameter by 27mm tall 
Possible test case verdicts: 
 
- test case does not apply to the test object ................. : N/A (or N) 
- test object does meet the requirement....................... : P (Pass) 
- test object does not meet the requirement ................ : F (Fail) 
Testing .......................................................................... :  
Date of receipt of test item ............................................ : 2010-06 
Date(s) of performance of tests .................................... : 2010-06 – 2010-07 
 
 
Page 7 of 49 
Report No. 152949 
 
 
TRF No. IEC60950_1B 
 
 
 
General remarks: 
The test results presented in this report relate only to the object tested. 
This report shall not be reproduced, except in full, without the written approval of the Issuing testing 
laboratory. 
"(see Enclosure #)" refers to additional information appended to the report. 
"(see appended table)" refers to a table appended to the report. 
 
Throughout this report a 
 comma / 
 point is used as the decimal separator. 
 
 
 
Manufacturer’s Declaration per sub-clause 6.2.5 of IECEE 02: 
The application for obtaining a CB Test Certificate 
includes more than one factory location and a 
declaration from the Manufacturer stating that the 
sample(s) submitted for evaluation is (are) 
representative of the products from each factory has 
been provided ................................................................:
 Yes 
 Not applicable 
 
When differences exist; they shall be identified in the General product information section. 
Name and address of factory (ies) .......................... :  
Guoguang Electric Co. Ltd. 
No. 8 Jinghu Road, Xinhua Street 
Huadu Region, Guangzhou,  
510800 P.R. China 
 
 
Page of 102