JBL RADIAL (serv.man5) EMC - CB Certificate ▷ View online
Page 8 of 49
Report No. 152949
TRF No. IEC60950_1B
General product information:
This report is an upgrade from IEC 60950-1, 1st edition to IEC 60950-1, 2nd edition. This report
replaces the original Test report, Ref. No. 60980. This Test Report also documents the change in
Applicant and Manufacturer name, change of factory, and change of enclosure material
manufacturer name and model/type.
The applicant and manufacturer has changed name from Harman Multimedia to Harman
Consumer, Inc..
The List of factories has also been updated with the new factory (refer to Name and address of
factories).
List of Critical Components has been updated to address the change of manufacturer name and
model/type on enclosure material.
replaces the original Test report, Ref. No. 60980. This Test Report also documents the change in
Applicant and Manufacturer name, change of factory, and change of enclosure material
manufacturer name and model/type.
The applicant and manufacturer has changed name from Harman Multimedia to Harman
Consumer, Inc..
The List of factories has also been updated with the new factory (refer to Name and address of
factories).
List of Critical Components has been updated to address the change of manufacturer name and
model/type on enclosure material.
The EUT is a desktop stereo system powered by a detachable Limited Power Source (desk top
PSU). The EUT is provided with an Ipod connection, USB, S video out and an auxiliary audio
input connection. The EUT is provided with an HB75 (Flame class) enclosure.
Maximum recommended ambient (Tmra): 40°C
Connection to the supply: Secondary Circuits, powered by external SELV, Limited Power Source.
1.1.2 - Additional requirements:
Exposure to extreme temperatures, excessive dust, moisture or vibration; to flammable gases; to
corrosive or explosive atmospheres:
This equipment is intended to operate in a "normal" environment (Offices and homes).
Electro medical equipment connected to the patient:
This equipment is not an electro medical equipment intended to be physically connected to a
patient.
Equipment used in vehicles, ships or aircrafts, in tropical countries, or at elevations > 2000m:
This equipment is intended to operate in a "normal" environment (Offices and homes).
PSU). The EUT is provided with an Ipod connection, USB, S video out and an auxiliary audio
input connection. The EUT is provided with an HB75 (Flame class) enclosure.
Maximum recommended ambient (Tmra): 40°C
Connection to the supply: Secondary Circuits, powered by external SELV, Limited Power Source.
1.1.2 - Additional requirements:
Exposure to extreme temperatures, excessive dust, moisture or vibration; to flammable gases; to
corrosive or explosive atmospheres:
This equipment is intended to operate in a "normal" environment (Offices and homes).
Electro medical equipment connected to the patient:
This equipment is not an electro medical equipment intended to be physically connected to a
patient.
Equipment used in vehicles, ships or aircrafts, in tropical countries, or at elevations > 2000m:
This equipment is intended to operate in a "normal" environment (Offices and homes).
Abbreviations used in the report:
-
normal
conditions
N.C.
- functional insulation
OP
-
double
insulation
DI
- between parts of opposite polarity
BOP
Indicate used abbreviations (if any)
- single fault conditions
S.F.C
- basic insulation
BI
- supplementary insulation
SI
- reinforced insulation
RI
Page 9 of 49
Report No. 152949
IEC
60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B
1 GENERAL
P
1.5 Components
P
1.5.1 General
P
Comply with IEC 60950-1 or relevant component
standard
standard
(see appended tables 1.5.1)
P
1.5.2
Evaluation and testing of components
Certified components are
used in accordance with their
ratings, certifications and they
comply with applicable parts
of this standard.
Components not certified are
used in accordance with their
ratings and they comply with
applicable parts of IEC
60950-1 and the relevant
component standard.
Components, for which no
relevant IEC-standard exists,
have been tested under the
conditions occurring in the
equipment, using applicable
parts of IEC 60950-1.
used in accordance with their
ratings, certifications and they
comply with applicable parts
of this standard.
Components not certified are
used in accordance with their
ratings and they comply with
applicable parts of IEC
60950-1 and the relevant
component standard.
Components, for which no
relevant IEC-standard exists,
have been tested under the
conditions occurring in the
equipment, using applicable
parts of IEC 60950-1.
P
1.5.3
Thermal controls
No thermal controls.
N/A
1.5.4
Transformers
Class III equipment to be
supplied by a separately
approved power supply with
an SELV output. Power
supply not evaluated. Refer to
Summary of Testing.
supplied by a separately
approved power supply with
an SELV output. Power
supply not evaluated. Refer to
Summary of Testing.
N/A
1.5.5 Interconnecting
cables
Suitable
cables
provided.
Refer to appended table
1.5.1.
1.5.1.
P
1.5.6
Capacitors bridging insulation
Class III equipment. No such
capacitors.
capacitors.
N/A
1.5.7
Resistors bridging insulation
No such components bridging
insulation. Class III
equipment.
insulation. Class III
equipment.
N/A
1.5.7.1
Resistors bridging functional, basic or
supplementary insulation
supplementary insulation
N/A
1.5.7.2
Resistors bridging double or reinforced insulation
between a.c. mains and other circuits
between a.c. mains and other circuits
N/A
1.5.7.3
Resistors bridging double or reinforced insulation
between a.c. mains and antenna or coaxial cable
between a.c. mains and antenna or coaxial cable
N/A
Page 10 of 49
Report No. 152949
IEC
60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B
1.5.8
Components in equipment for IT power systems
Class III equipment.
N/A
1.5.9
Surge suppressors
Class III equipment. No such
component.
component.
N/A
1.5.9.1 General
N/A
1.5.9.2
Protection of VDRs
N/A
1.5.9.3
Bridging of functional insulation by a VDR
N/A
1.5.9.4
Bridging of basic insulation by a VDR
N/A
1.5.9.5
Bridging of supplementary, double or reinforced
insulation by a VDR
insulation by a VDR
N/A
1.6 Power
interface
P
1.6.1
AC power distribution systems
Class III equipment.
N/A
1.6.2
Input current
(see appended table 1.6.2)
P
1.6.3
Voltage limit of hand-held equipment
The equipment is not hand-
held.
held.
N/A
1.6.4
Neutral conductor
Class III equipment.
N/A
1.7
Marking and instructions
P
1.7.1
Power rating and identification markings
P
1.7.1.1
Power rating marking
Marking not required,
however the marking is
located on the outside surface
of the equipment.
however the marking is
located on the outside surface
of the equipment.
P
Multiple mains supply connections..........................: Class III equipment.
N/A
Rated voltage(s) or voltage range(s) (V) .............. : 24VDC
P
Symbol for nature of supply, for d.c. only ............... : IEC 60417-1, symbol
No. 5031, is used.
P
Rated frequency or rated frequency range (Hz) ... :
N/A
Rated current (mA or A) ........................................ : 2.3A
P
1.7.1.2 Identification
markings
P
Manufacturer’s name or trade-mark or identification
mark ...................................................................... :
mark ...................................................................... :
P
Model identification or type reference ................... : Radial
P
Symbol for Class II equipment only ...................... : The equipment is Class III.
N/A
Other markings and symbols ................................ : The additional marking does
not give rise to
misunderstandings.
misunderstandings.
P
Page 11 of 49
Report No. 152949
IEC
60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B
1.7.2
Safety instructions and marking
Provided with marking
regarding use of specified
power supply, refer to copy of
marking plate.
regarding use of specified
power supply, refer to copy of
marking plate.
P
1.7.2.1 General
P
1.7.2.2
Disconnect devices
Class III equipment.
N/A
1.7.2.3
Overcurrent protective device
Class III equipment.
N/A
1.7.2.4
IT power distribution systems
Class III equipment.
N/A
1.7.2.5
Operator access with a tool
Class III equipment. Supplied
from a LPS.
from a LPS.
N/A
1.7.2.6 Ozone
No
Ozone
generator.
N/A
1.7.3
Short duty cycles
The equipment is intended for
continuous operation.
continuous operation.
N/A
1.7.4
Supply voltage adjustment ................................... :
No voltage selector.
N/A
Methods and means of adjustment; reference to
installation instructions ......................................... :
installation instructions ......................................... :
N/A
1.7.5
Power outlets on the equipment .......................... :
No standard power outlet.
N/A
1.7.6
Fuse identification (marking, special fusing
characteristics, cross-reference) .......................... :
characteristics, cross-reference) .......................... :
No fuses.
N/A
1.7.7
Wiring terminals
Class III equipment.
N/A
1.7.7.1
Protective earthing and bonding terminals .......... :
N/A
1.7.7.2
Terminals for a.c. mains supply conductors
N/A
1.7.7.3
Terminals for d.c. mains supply conductors
N/A
1.7.8
Controls and indicators
Refer below:
P
1.7.8.1
Identification, location and marking ...................... :
No controls or figures
affecting safety provided.
affecting safety provided.
N/A
1.7.8.2
Colours ................................................................ :
No controls or indicators us
color.
color.
N/A
1.7.8.3
Symbols according to IEC 60417 ......................... :
There are no switches in the
equipment. Control is marked
with “+” and “-“.
equipment. Control is marked
with “+” and “-“.
P
1.7.8.4
Markings using figures ....................................... :
N/A
1.7.9
Isolation of multiple power sources ..................... :
Class III equipment. Single
connection.
connection.
N/A
1.7.10
Thermostats and other regulating devices .......... :
No thermostats or other
regulating devices.
regulating devices.
N/A
1.7.11
Durability
The marking withstands
required tests.
required tests.
P
1.7.12 Removable
parts
No
removable
parts.
P
Click on the first or last page to see other RADIAL (serv.man5) service manuals if exist.