DOWNLOAD JBL RADIAL MICRO (serv.man3) Service Manual ↓ Size: 2.37 MB | Pages: 74 in PDF or view online for FREE

Model
RADIAL MICRO (serv.man3)
Pages
74
Size
2.37 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
radial-micro-sm3.pdf
Date

JBL RADIAL MICRO (serv.man3) EMC - CB Certificate ▷ View online

Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
April 8, 2008 
Harman Multimedia - JBL Radial Micro - EMC Test Report 
2006 100765 EMC Rev.1 
37 of 74 
 
7.2.  Radiated Emissions Test Data 
 
 
San Diego Headquarters:
11696 Sorrento Valley Rd.
San Diego, CA 92121
Tel:  (858) 755-5525
NEMKO USA, Inc.
Fax: (858) 452-1810
Radiated Emissions Data
Complete
X
Job # : 26-765-HAR
Test # : 1
Preliminary
Page
1
of
1
Client Name :
Harman Multimedia
EUT Name :
Speaker System
EUT Model # :
JBL Radial Micro
EUT Part # :
EUT Serial # :
EUT Config. :
Ipod Nano (Playing "EIA noise 250 seconds -15dB")
Audio cable + terminated USB cable
Specification :
EN55022: 1998, Class B
   Reference :
Rod. Ant. #:
NA
Temp. (deg. C) :
22
Date : Oct. 24, 2006
Bicon Ant.#:
114
Humidity (%) :
61
Time : 11:00AM
Log Ant.#:
110
EUT Voltage :
230VAC
Staff : FSCustodio
DRG Ant. #
NA
EUT Frequency :
50Hz
Quasi-Peak RBW: 120 kHz
Dipole Ant.#:
NA
Phase:
1
Video Bandwidth 120 kHz
Cable#:
NOATS
Location:
NOATS
Average RBW: 1 MHz
Preamp#:
901
Distance:
10m
Video Bandwidth 10 Hz
Spec An.#:
674/675
Peak RBW: 1 MHz
QP #:
676
Video Bandwidth 1 MHz
PreSelect#:
NA
Measurements below 1 GHz are Quasi-Peak values, unless otherwise stated.
Measurements above 1 GHz are Average values, unless otherwise stated.
Meas.
Ant.
Atten.
Meter
Antenna
Path
RF
Corrected
Spec.
CR/SL
Pass
Freq.
Pol.
Reading
Factor
Loss
Gain
Reading
limit
Diff.
Fail
(MHz)
(H/V)
(dB)
(dBuV)
(dB)
(dB)
(dB)
(dBuV/m) (dBuV/m)
(dB)
Unc.
Comment
32.074
V
41.31
12.9
1.0
31.8
23.4
30.0
-6.6
Pass
46.643
V
45.79
11.3
1.2
31.9
26.4
30.0
-3.6
Pass
82.037
V
43.91
6.6
1.6
32.0
20.1
30.0
-9.9
Pass
129.35
V
40.25
12.7
1.8
31.9
22.9
30.0
-7.1
Pass
183.95
V
42.8
16.9
2.2
32.0
29.9
30.0
-0.1
Pass
327.56
V
42.39
14.6
3.2
31.7
28.5
37.0
-8.5
Pass
Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
April 8, 2008 
Harman Multimedia - JBL Radial Micro - EMC Test Report 
2006 100765 EMC Rev.1 
38 of 74 
 
 
8.  CE-mark Test Results 
8.1.  Conducted Emissions Test Data 
Client 
Harman Multimedia 
Temperature 72 
deg 
PAN # 
26-765-HAR 
Relative Humidity 
50 
EUT Name 
Speaker System 
Barometric Pressure  30.22 
Hg 
EUT Model  
JBL Radial Micro 
Test Location 
Enclosure 2 
Governing Doc 
EN 55022 
Test Engineer 
Mike Escano 
Basic Standard 
EN 55022 
Date 
October 27, 2006 
Nemko USA, Inc.
EN 55022 Class B Conducted Emissions
230VAC @ 50Hz, L1 PK, QP = 0, AV = X
100.0K
1.0M
10.0M
100.0M
Frequency
0
10.0
20.0
30.0
40.0
50.0
60.0
70.0
80.0
90.0
100.0
Am
pl
it
ude (
dbuV)
09:43:44 AM, Friday, October 27, 2006
Harman Multimedia
JBL Radial Micro Speaker System
26-765-EMC
 
 
 
Nemko USA, Inc.
EN 55022 Class B Conducted Emissions
230VAC @ 50Hz, L2 PK, QP = 0, AV = X
100.0K
1.0M
10.0M
100.0M
Frequency
0
10.0
20.0
30.0
40.0
50.0
60.0
70.0
80.0
90.0
100.0
Am
pl
it
ude (
dbuV)
09:39:52 AM, Friday, October 27, 2006
Harman Multimedia
JBL Radial Micro Speaker System
26-765-EMC
 
 
Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
April 8, 2008 
Harman Multimedia - JBL Radial Micro - EMC Test Report 
2006 100765 EMC Rev.1 
39 of 74 
 
 
Conducted Emissions Test Equipment
 
Client 
Harman MultimediaHarman 
Multimedia
  
EUT Name 
Speaker System 
PAN #  26-765-HAR 
EUT Model   JBL Radial Micro 
Device Type 
Model # 
Asset # 
Used 
Cal Done 
Cal Due 
Pre-Amplifier 
Amplifier, HP 
8447A 
342 
 
 
 
Amplifier, HP 
8447A 
166 
 
 
 
Amplifier, HP 
8447A 
603 
 
 
 
 
 
 
 
 
 
Filter / Limiter  
High Pass Filter, Solar 
7801-5.0 
564 
 
 
 
High Pass Filter, Solar 
8310-1.0 559 
3/01/06 
3/01/07 
Transient Limiter, HP 
11947A 
682 
 
 
 
Transducer 
LISN, EMCO 
3825/2 – FCC 
147 
 
 
 
LISN, Electro-Metrics 
LISN – VDE 
425 
 
 
 
V-Network LISN, Solar 
9348-50-R-24-BNC 
805 
11/16/05 
11/16/06 
V-Network LISN, Solar 
9348-50-R-24-BNC 
395 
 
 
 
Voltage Line Probe, EMCO 
3701 
471 
 
 
 
LISN, Solar 
8602-50-TS-50-N 
424 
 
 
 
LISN, Solar 
8602-50-TS-50-N 
423 
 
 
 
 
 
 
 
 
 
Spectrum Analyzer / Receiver 
Quasi-Peak Adapter, HP 
Spectrum Analyzer Display, HP 
Spectrum Analyzer, HP 
85650A 
85662A 
85680A 
533 
422 
535 
X 4/12/06  4/12/07 
RF Preselector, HP 
85650A 
673 
 
 
 
Quasi-Peak Adapter, HP 
Spectrum Analyzer Display, HP 
Spectrum Analyzer, HP 
85650A 
85662A 
8568B 
438 
107 
422 
 
 
 
Quasi-Peak Adapter, HP 
Spectrum Analyzer Display, HP 
Spectrum Analyzer, HP 
85650A 
85662A 
8568B 
676 
675 
674 
 
 
 
Quasi-Peak Adapter, HP 
Spectrum Analyzer Display, HP 
Spectrum Analyzer, HP 
85650A 
85662A 
8568B 
421 
422 
535 
 
 
 
Quasi-Peak Adapter, HP 
Spectrum Analyzer Display, HP 
Spectrum Analyzer, HP 
85650A 
85662A 
8566B 
538 
534 
107 
 
 
 
RF Preselector, HP 
85685A 
403 
 
 
 
Spectrum Analyzer, Advantest 
R3261 
523 
 
 
 
 
 
 
 
 
 
 
Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
April 8, 2008 
Harman Multimedia - JBL Radial Micro - EMC Test Report 
2006 100765 EMC Rev.1 
40 of 74 
 
8.2.  Radiated Emissions Test Data 
 
 
San Diego Headquarters:
11696 Sorrento Valley Rd.
San Diego, CA 92121
Tel:  (858) 755-5525
NEMKO USA, Inc.
Fax: (858) 452-1810
Radiated Emissions Data
Complete
X
Job # : 26-765-HAR
Test # : 1
Preliminary
Page
1
of
1
Client Name :
Harman Multimedia
EUT Name :
Speaker System
EUT Model # :
JBL Radial Micro
EUT Part # :
EUT Serial # :
EUT Config. :
Ipod Nano (Playing "EIA noise 250 seconds -15dB")
Audio cable + terminated USB cable
Specification :
EN55022: 1998, Class B
   Reference :
Rod. Ant. #:
NA
Temp. (deg. C) :
22
Date : Oct. 24, 2006
Bicon Ant.#:
114
Humidity (%) :
61
Time : 11:00AM
Log Ant.#:
110
EUT Voltage :
230VAC
Staff : FSCustodio
DRG Ant. #
NA
EUT Frequency :
50Hz
Quasi-Peak RBW: 120 kHz
Dipole Ant.#:
NA
Phase:
1
Video Bandwidth 120 kHz
Cable#:
NOATS
Location:
NOATS
Average RBW: 1 MHz
Preamp#:
901
Distance:
10m
Video Bandwidth 10 Hz
Spec An.#:
674/675
Peak RBW: 1 MHz
QP #:
676
Video Bandwidth 1 MHz
PreSelect#:
NA
Measurements below 1 GHz are Quasi-Peak values, unless otherwise stated.
Measurements above 1 GHz are Average values, unless otherwise stated.
Meas.
Ant.
Atten.
Meter
Antenna
Path
RF
Corrected
Spec.
CR/SL
Pass
Freq.
Pol.
Reading
Factor
Loss
Gain
Reading
limit
Diff.
Fail
(MHz)
(H/V)
(dB)
(dBuV)
(dB)
(dB)
(dB)
(dBuV/m) (dBuV/m)
(dB)
Unc.
Comment
32.074
V
41.31
12.9
1.0
31.8
23.4
30.0
-6.6
Pass
46.643
V
45.79
11.3
1.2
31.9
26.4
30.0
-3.6
Pass
82.037
V
43.91
6.6
1.6
32.0
20.1
30.0
-9.9
Pass
129.35
V
40.25
12.7
1.8
31.9
22.9
30.0
-7.1
Pass
183.95
V
42.8
16.9
2.2
32.0
29.9
30.0
-0.1
Pass
327.56
V
42.39
14.6
3.2
31.7
28.5
37.0
-8.5
Pass
 
 
Page of 74
Display