JBL RADIAL MICRO (serv.man3) EMC - CB Certificate ▷ View online

Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
April 8, 2008 
Harman Multimedia - JBL Radial Micro - EMC Test Report 
2006 100765 EMC Rev.1 
25 of 74 
 
Figure 6.   EFT Immunity Test Setup Diagram 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
NOT TO SCALE 
 
CONFIGURATION LEGEND 
 
1.  Test Laboratory (6 x 7 meters) 
2. Ground 
Plane 
3.  Power Strip for Peripherals from power line filter  
4.  DC Power for Devices 
5.  Capacitive Coupling Clamp (grounded) 
6.  Mains Power for EUT 
7.  AC Power for Fast Transient Noise Generator (120V) 
8.  Fast Transient Noise Generator 
9. Coupling 
Network 
10.  10cm Non-Conducting Platform  
11. EUT  
12. Associated System 
 
10 
8
 
6
 
5
11 
10 
12 
Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
April 8, 2008 
Harman Multimedia - JBL Radial Micro - EMC Test Report 
2006 100765 EMC Rev.1 
26 of 74 
 
 
4.10.  Power Line Surge Immunity: IEC 61000-4-5: 2005 
 
This test simulates a lightning event by inducing transients onto the AC/DC power supply lines in common 
and differential mode.  Testing was performed in accordance with IEC 61000-4-5. 
Each device was tested in a total of three surge configurations: 
 
Surge #1: Combination Wave, Line to Protective Earth with 9uF and 10Ohm, common mode, generator 
earthed. 
Surge #2: Combination Wave, Neutral to Protective Earth with 9uF and 10Ohm, common mode, 
generator earthed. 
Surge #3: Combination Wave, Line to Neutral with 18uF, differential mode, generator floated. 
 
For further information, please refer to the technical sections in the IEC 61000-4-5 in addition to the test 
results section and photographs of the test set-up provided in this report. 
Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
April 8, 2008 
Harman Multimedia - JBL Radial Micro - EMC Test Report 
2006 100765 EMC Rev.1 
27 of 74 
 
Figure 7.   Power Line Surge Immunity Test Setup Diagram 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
NOT TO SCALE 
 
CONFIGURATION LEGEND 
 
1. Test 
Laboratory 
2.  AC power for Devices 
3.  Power strip for associated devices from power line filter 
4.  Copper Ground Plane  
5. Surge 
Generator 
6.  Surge Coupling Network 
7.  Nonconductive tables 80cm above Ground Plane 
8. EUT 
 
9. Associated 
System 
 
 
Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
April 8, 2008 
Harman Multimedia - JBL Radial Micro - EMC Test Report 
2006 100765 EMC Rev.1 
28 of 74 
 
4.11.  Radio Frequency Conducted Common Mode Immunity: IEC 61000-4-6 
 
This test injects a disturbance directly onto AC/DC power and signal I/O cables.  Testing was performed in 
accordance with IEC 61000-4-6.  The standard configuration as outlined in the IEC 61000-4-6 was used.  For 
further information, please refer to the technical sections of the IEC 61000-4-6 publication in addition to the 
test results section and photographs of the test set-up provided in this report. 