JBL RADIAL MICRO (serv.man3) EMC - CB Certificate ▷ View online
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
April 8, 2008
Harman Multimedia - JBL Radial Micro - EMC Test Report
2006 100765 EMC Rev.1
29 of 74
Figure 8. RF Common Mode Immunity Test Setup Diagram
NOT TO SCALE
CONFIGURATION LEGEND
1. Test
Laboratory
2. DC power for EUT
3. Ground
3. Ground
Plane
4. 10cm wooden Platform
5. Test
5. Test
Generator
6. Current
Probe
7. Coupling/Decoupling
Network
8. Coupling/Decoupling
Network
9. EUT
10. Associated System
1
2
9
6
5
7
10
3
4
8
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
April 8, 2008
Harman Multimedia - JBL Radial Micro - EMC Test Report
2006 100765 EMC Rev.1
30 of 74
4.12. Voltage Dips and Short Interruptions: IEC 61000-4-11: 2004
This test subjects the EUT to power network faults and “brownouts”. Testing was performed in accordance
with IEC 61000-4-11. The standard configuration as outlined in the IEC 61000-4-11 was used. The EUT is
powered up to a nominal voltage of 230 VAC 50 Hz, and then software-controlled voltage dips and
interruptions are introduced. For further information, please refer to the technical sections of the IEC 61000-
4-11 in addition to the test results section and photographs of the test set-up provided in this report.
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
April 8, 2008
Harman Multimedia - JBL Radial Micro - EMC Test Report
2006 100765 EMC Rev.1
31 of 74
Figure 9. Voltage Dips and Short Interruptions Test Setup Diagram
N
OT TO
S
CALE
CONFIGURATION LEGEND
1. Test Laboratory (6 X 6 meters)
2. AC Power for Devices
3. 120/208VAC/60Hz Power for Harmonics/Flicker Test Equipment
4. 115V/60 Hz Power Distribution Box
5. Power Source Rack with Computer Analysis System
6. Non-conducting
table
7. EUT and Associated System
3
4
1
2
6
7
5
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
April 8, 2008
Harman Multimedia - JBL Radial Micro - EMC Test Report
2006 100765 EMC Rev.1
32 of 74
5. FCC Test Results
5.1. Conducted Emissions Test Data
Client
Harman Multimedia
Temperature
72
deg F
PAN #
26-765-HAR
Relative Humidity
50
%
EUT Name
Speaker System
Barometric Pressure 30.22
Hg
EUT Model
JBL Radial Micro
Test Location
Enclosure 2
Governing Doc
CFR 47, Part 15B
Test Engineer
Mike Escano
Basic Standard
Sec. 15.107
Date
October 27, 2006
Nemko USA, Inc.
FCC Class B Conducted Emissions
120VAC @ 60Hz, L1 PK, QP = 0, AV = X
100.0K
1.0M
10.0M
100.0M
Frequency
0
10.0
20.0
30.0
40.0
50.0
60.0
70.0
80.0
90.0
100.0
Amplitude (dbuV)
09:27:36 AM, Friday, October 27, 2006
Harman Multimedia
JBL Radial Micro Speaker System
26-765-EMC
JBL Radial Micro Speaker System
26-765-EMC
Nemko USA, Inc.
FCC Class B Conducted Emissions
120VAC @ 60Hz, L2 PK, QP = 0, AV = X
100.0K
1.0M
10.0M
100.0M
Frequency
0
10.0
20.0
30.0
40.0
50.0
60.0
70.0
80.0
90.0
100.0
Ampl
it
ude
(
dbuV)
09:34:36 AM, Friday, October 27, 2006
Harman Multimedia
JBL Radial Micro Speaker System
26-765-EMC
JBL Radial Micro Speaker System
26-765-EMC
Click on the first or last page to see other RADIAL MICRO (serv.man3) service manuals if exist.