JBL RADIAL MICRO (serv.man3) EMC - CB Certificate ▷ View online
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
April 8, 2008
Harman Multimedia - JBL Radial Micro - EMC Test Report
2006 100765 EMC Rev.1
45 of 74
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
April 8, 2008
Harman Multimedia - JBL Radial Micro - EMC Test Report
2006 100765 EMC Rev.1
46 of 74
8.4. Power Line Fluctuations / Flicker Test Results
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
April 8, 2008
Harman Multimedia - JBL Radial Micro - EMC Test Report
2006 100765 EMC Rev.1
47 of 74
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
April 8, 2008
Harman Multimedia - JBL Radial Micro - EMC Test Report
2006 100765 EMC Rev.1
48 of 74
Power Line Harmonics and Flicker Test Equipment
Client
Harman Multimedia
Temperature 78
deg
F
PAN #
26-765-HAR
Relative Humidity
60
%
EUT Name
Speaker System
Barometric Pressure
30.21 Hg
EUT Model
JBL Radial Micro
Test Location
West Ground Plane
Governing Doc
EN 55022
Test Engineer
Mike Escano
Basic Standard
IEC 61000-3-2 and
IEC 61000-3-3
IEC 61000-3-3
Date
October 31, 2006
EUT Voltage:
X 230VAC @ 50Hz
120VAC @ 60Hz
Equipment Used Used Asset
# Cal
Done Cal
Due
California Instruments AC Power
X
604 NCR
NCR
Xitron 2520 Standard Impedance
X
581 1/3/06
1/3/07
Xitron 2503AH Power Analysis System
X
582 1/3/06
1/3/07
Photo X
Click on the first or last page to see other RADIAL MICRO (serv.man3) service manuals if exist.