DOWNLOAD JBL RADIAL MICRO (serv.man3) Service Manual ↓ Size: 2.37 MB | Pages: 74 in PDF or view online for FREE

Model
RADIAL MICRO (serv.man3)
Pages
74
Size
2.37 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
radial-micro-sm3.pdf
Date

JBL RADIAL MICRO (serv.man3) EMC - CB Certificate ▷ View online

Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
April 8, 2008 
Harman Multimedia - JBL Radial Micro - EMC Test Report 
2006 100765 EMC Rev.1 
49 of 74 
 
8.5.  Electrostatic Discharge Immunity Test Results & Test Points 
 
Client: 
Harman Multimedia 
Temperature: 79 
degF 
PAN #: 
26-765-HAR 
Relative Humidity: 
61 
EUT Name: 
Speaker System 
Barometric Pressure: 
30.14 
Hg 
EUT Model: 
JBL Radial Micro 
Test Location 
Enclosure 2 
Governing Doc: 
EN 55024 
Test Engineer 
Mike Escano 
Basic Standard: 
EN 61000-4-2 
Date: 
October 30, 2006 
Voltage: 230VAC/ 
50Hz 
Discharge Rep. Rate 
> 1 per second 
 
 
Number of Discharges 
> 10 per location 
 
 
Equipment Used 
Device Type 
Model # 
Asset # 
Used 
Cal Done 
Cal Due 
ESD Gun, Haefely 
PSD-25B 
639 
 
 
 
ESD Gun, Keytek 
PSC 
377 
 
 
 
ESD Gun, Schaffner 
NSG 435 
818 
1/19/06 
1/19/07 
EMC Partner 
Transient 2000 
845 
 
 
 
EMC Partner 
ESD 2000 
890 
 
 
 
 
Location of Discharge 
Contact Discharge 
Polarity 
Voltage 
(kV) 
Pos Neg 
Numbers HCP  VCP 
2 X X 
None 
4 X X 
None 
 
 
 
 
 
 
Comments:   
 
Air Discharge 
Polarity 
Voltage 
(kV) 
Pos Neg 
Numbers 
2 X X 
None 
4 X X 
None 
8 X X 
 
 
 
 
 
Comments:   At 8kV, hitting the USB port decreased the volume. 
 
Compliant X 
 
Non-Compliant 
  
 
Photo X  
 
Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
April 8, 2008 
Harman Multimedia - JBL Radial Micro - EMC Test Report 
2006 100765 EMC Rev.1 
50 of 74 
 
 
Figure 10.  ESD Test Points 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Contact Discharges = 
 
Air Discharges = 
Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
April 8, 2008 
Harman Multimedia - JBL Radial Micro - EMC Test Report 
2006 100765 EMC Rev.1 
51 of 74 
 
8.6.  Radio Frequency Immunity Test Results 
 
Client: 
Harman Multimedia 
Temperature: 81 
degF 
PAN #: 
26-765-HAR 
Relative Humidity: 
56 
EUT Name: 
Speaker System 
Barometric Pressure: 
30.19 
Hg 
EUT Model: 
JBL Radial Micro 
Test Location 
Anechoic Chamber 
Governing Doc: 
EN 55024 
Test Engineer 
Mike Escano 
Basic Standard: 
EN 61000-4-3 
Date: 
October 31, 2006 
Voltage: 230VAC/ 
50Hz 
Threat Levels 
Frequency (MHz): 
 27-500 
80-6000 
 26-1000 
  
Test Level: 
 1V/m 
3V/m 
 10V/m 
 200V/m 
Modulation: 
 
None (CW) 
X  80% AM, 1kHz 
 
50% PM, 200Hz 
 
 
Frequency Step: 
1% 
 3% 
  
  
Dwell Time: 
X  2 sec 
 
3 sec 
 
10 sec 
 
 
Criteria: 
 B 
 C 
  
Antenna 
Polarization 
Compliant 
Frequency (MHz) 
H V Y N 
Orientation 
F: Front 
R: Rear 
SL: Side, Left 
SR: Side, Right 
Comments 
80-200 
 
 
No Susceptibility Noted 
200-1000 
 
 
No Susceptibility Noted 
1000-6000 
 
 
No Susceptibility Noted 
80-200 
X  X  
F  No 
Susceptibility 
Noted 
200-1000 
X  X  
F  No 
Susceptibility 
Noted 
1000-6000 
X  X  
F  No 
Susceptibility 
Noted 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Compliant X  
Not 
Compliant     
Photo  X  
 
Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
April 8, 2008 
Harman Multimedia - JBL Radial Micro - EMC Test Report 
2006 100765 EMC Rev.1 
52 of 74 
 
 
Radio Frequency Immunity Test Equipment
 
Client 
Harman Multimedia 
EUT Name 
Speaker System 
PAN #  26-765-HAR 
EUT Model   JBL Radial Micro 
Device Type 
Model # 
Asset # 
Used 
Cal Done 
Cal Due 
Signal Generator 
HP 8542B 
751 
 
 
 
HP 8648 
746 
 
 
 
Gigatronics 1018 
440 
12/09/05 
12/09/06 
Fluke 6060B 
212 
 
 
 
 
 
 
 
 
 
Power Meter 
Boonton EMCO 
 
 
 
 
 
 
 
 
 
 
Field Sensors 
AR FP4000 
730 
 
 
 
AR FP4080 
734 
9/5/06 
9/5/07 
 
 
 
 
 
 
Amplifier / Directional Couplers 
AR 200T2G8 
848 
NCR 
NCR 
AR DC2035 
727 
 
NCR 
NCR 
AR 500W1000M5 
740 
NCR 
NCR 
AR DC618D 
747 
 
NCR 
NCR 
AR CP3001 
742 
NCR 
NCR 
AR DC714D 
724 
 
NCR 
NCR 
AR 200T2G8M4 
744 
 
NCR 
NCR 
AR DC7280 
726 
 
NCR 
NCR 
AR 200T8G18M3 
745 
 
NCR 
NCR 
AR DC7450 
723 
 
NCR 
NCR 
Antennas 
IFI EFG-38 
748 
 
NCR 
NCR 
BiLog AC-220 
906 
NCR 
NCR 
Electro-Metrics RGA-25 
372 
 
NCR 
NCR 
Electro-Metrics RGA-30 
350 
 
NCR 
NCR 
EMCO 3115 
723 
 
NCR 
NCR 
AR AT4002A 
728 
NCR 
NCR 
 
 
 
 
 
 
 
 
 
Page of 74
Display