DOWNLOAD JBL RADIAL MICRO (serv.man3) Service Manual ↓ Size: 2.37 MB | Pages: 74 in PDF or view online for FREE

Model
RADIAL MICRO (serv.man3)
Pages
74
Size
2.37 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
radial-micro-sm3.pdf
Date

JBL RADIAL MICRO (serv.man3) EMC - CB Certificate ▷ View online

Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
April 8, 2008 
Harman Multimedia - JBL Radial Micro - EMC Test Report 
2006 100765 EMC Rev.1 
53 of 74 
 
8.7.  Electrical Fast Transient Burst Immunity Test Results 
Client 
Harman Multimedia 
Temperature 5 
deg 
PAN # 
26-765-HAR 
Relative Humidity 
38 
EUT Name 
Speaker System 
Barometric Pressure 
30.30 
Hg 
EUT Model  
JBL Radial Micro 
Test Location 
Enclosure 2 
Governing Doc 
EN 55024 
Test Engineer 
Mike Escano 
Basic Standard 
EN 61000-4-4 
Date 
October 30, 2006 
Test Level: 
 
 
 
 
AC / DC Mains / Control Ports 
 
0.5kV 
X  1.0kV 
 
2.0kV 
 
4.0kV 
  ______ 
Signal 
Ports 
 0.25kV   0.5kV   1.0kV 
 2.0kV  ______ 
 
 
 
 
 
Test Duration: 
X 61 
sec 
  _______ 
 
 
 
 
 
 
 
Test Equipment  
 
Asset # Used Calibration 
Done Calibration 
Due 
Haefely P90.1 Generator 
416 
11/22/05 
11/22/06 
Haefely 093 506.1 Clamp 
417 
 
 
 
Haefely FP-EFT Generator 32.1 
689 
 
 
 
Noiseken FNS-100L 
547 
 
 
 
Noiseken 15-00001A Clamp 
802 
 
NCR 
NCR 
EMC Partner Transient 2000 
845 
 
 
 
 
 
 
 
Performance Criteria: 
 
X  
 
 
Direct Injection Output Path 
Test Level 
Polarity 
(+/-) 
L1 L2 PE 
Comments 
1.0kV +/- X   
 
 1.0kV 
+/- 
 
 
 
1.0kV +/- X 
X  
 
 
.5kV +/-    
 
 
.5kV +/-    
 
.5kV  +/-    
 
Cable Description (Clamp Injection) Polarity 
 
 
 
 
 
 
Compliant   X 
 
Non-Compliant  
 
 
Photo  
X   
 
Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
April 8, 2008 
Harman Multimedia - JBL Radial Micro - EMC Test Report 
2006 100765 EMC Rev.1 
54 of 74 
 
8.8.  Power Line Surge Immunity Test Results 
Client 
Harman Multimedia 
Temperature 81 
deg 
PAN # 
26-765-HAR 
Relative Humidity 
75 
EUT Name 
Speaker System 
Barometric Pressure 
30.21  Hg 
EUT Model  
JBL Radial Micro 
Test Location 
West Ground Plane 
Governing Doc 
EN 55024 
Test Engineer 
Mike Escano 
Basic Standard 
EN 61000-4-5 
Date 
October 30, 2006 
 
 
 
 
 
 
 
 
 
 
EUT Power: 
Number of Strikes per Polarity/Voltage/Angle 
Repetition # Angle 
  X  230VAC @ 50Hz 
X  Five (5) 
0º 
   
230/400VAC @ 50 Hz 
 
Twenty (20) 
90º 
   
120VAC @ 60 Hz 
 
 
180º 
    
   
270º 
 
 
 
 
 
 
 
Waveform Generator Type: 
 Ring 
Wave  X 
Combination 
 
 
 
Test Equipment: Asset 
# Used Calibration 
Done Calibration 
Due 
Haefely PSurge 4010 
687 
 
 
 
Haefely FP Surge 32.1 
688 
 
NCR 
NCR 
Haefely PC6 288.1 
413 
 
 
 
Haefely FP Surge 16.1 
412 
 
NCR 
NCR 
EMC Partner Transient 2000 
845 
3/15/06 
3/15/07 
 
 
 
 
 
 
 
 
 
 
 
 
Performance 
Criteria:   A   X 
B    C 
 
 
L - Gnd 
0.5kV (Level 1) 
1.0kV (Level 2) 
2.0kV (Level 3) 
4.0kV (Level 4) 
??kV (Special) 
L - L 
X  0.25kV (Level 1)  X  0.5kV (Level 2) 
X 1.0kV (Level 3) 
2.0kV (Level 4) 
??kV (Special) 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Level 1 
Level 2 
Level 3 
Level 4 
Special 
  CM  DM  CM  DM  CM  DM  CM DM CM DM 
 0.5kV 
0.25kV 
1.0kV 
0.5kV 
2.0kV 
1.0kV 
4.0kV 
2.0kV  
 
 
+ - + - + - + - + - + - + - + - + - + - 
N–Gnd    
   
   
   
   
L1–Gnd    
 
 
 
 
 
 
 
 
 
 
 
 
 
N-L1 
 
X X 
 
X X 
 
X X 
 
 
 
 
 
 
 
 
Compliant   X   
Non-Compliant  
 
Photo  X   
 
Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
April 8, 2008 
Harman Multimedia - JBL Radial Micro - EMC Test Report 
2006 100765 EMC Rev.1 
55 of 74 
 
8.9.  RF Conducted Common Mode Disturbance Immunity Test Results 
 
 
 
 
Client 
Harman Multimedia 
Temperature 77 
deg 
PAN # 
26-765-HAR 
Relative Humidity 
32 
EUT Name 
Speaker System 
Barometric Pressure 
30.36 
Hg 
EUT Model  
JBL Radial Micro 
Test Location 
West Ground Plane 
Governing Doc 
EN 55024 
Test Engineer 
Mike Escano 
Basic Standard 
EN 61000-4-6 
Date 
October 27, 2006 
 
 
Test Level: X 
3Vrms 
 
10Vrms 
 
 
Modulation: 
 
None (CW)  
80%AM @ 1kHz 
 
 
Frequency Range: X 
0.15 – 80 MHz   
0.15-230MHz 
 
 
Step: X 
1% 
 
10% 
 
1.5 x 10¯³ /decade 
Performance Criteria: 
 
 
 
 
 
 
1  Injection Point (Cable)  Power Cord 
Injection Method:  
Clamp 
X  CDN 
Comments: 
Between 15MHz and 42MHz an interruption would occur where the audio would cycle on and 
off. However, the EUT would self-recover after the test. 
2  Injection Point (Cable)  New Power Cord 
Injection Method:  
Clamp 
X  CDN 
Comments: 
Between 14.7MHz and 23.2MHz an interruption would occur where the audio would cycle on and 
off. However, the EUT would self-recover after the test. 
3  Injection Point (Cable)  New Power Cord w/ Ferrite 
Injection Method:  
Clamp 
X  CDN 
Comments: 
From about 13.6MHz to 80MHz, an interruption would occur where the audio would cycle on and 
off. However, the EUT would self-recover after the test. At 61MHz, a high pitch noise would 
sound. 
4  Injection Point (Cable)  New Power Cord 
Injection Method:  
Clamp 
X  CDN 
Comments: 
From about 15MHz to 80MHz, an interruption would occur where the audio would cycle on and 
off. However, the EUT would self-recover after the test. 
5  Injection Point (Cable)  New Power Cord w/ Ferrite 
Injection Method   
Clamp 
X  CDN 
Comments: 
From about 15MHz to 80MHz, an interruption would occur where the audio would cycle on and 
off. However, the EUT would self-recover after the test. At 61MHz, a high pitch noise 
Comments: 
The client accepts lower criterion for this test. 
 
 
 
 
 
Test Equipment Used 
 
Asset # 
X if Used Calibration 
Done Calibration 
Due 
HP 8462B  (Signal Generator) 
751 
 
 
 
Fluke 6060B  (Signal Generator) 
212 
 
 
 
HP 8648B  (Signal Generator) 
746 
10/31/05 
10/31/06 
FCC-801-M1-25  (CDN) 
473 
 
 
 
FCC-801-M2-25  (CDN) 
472 
10/02/06 
10/02/07 
FCC-801-M3-25A  (CDN) 
846 
 
 
 
FCC-801-M4-25  (CDN) 
628 
 
 
 
FCC-801-M5-25  (CDN) 
629 
 
 
 
FCC-801-T2  (CDN) 
626 
 
 
 
FCC-801-T4  (CDN) 
627 
 
 
 
Amplifier 3100L 
913 
8/11/06 
8/11/07 
IFI 1500  (Amplifier) 
571 
 
NCR 
NCR 
RF Power Labs  (Amplifier) 
397 
 
NCR 
NCR 
Solar 9144-1N  (Clamp) 
436 
 
 
 
Solar 9121-1N  (Clamp) 
435 
 
 
 
Compliant     
 
Non-Compliant 
X   
Photo X   
 
Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
April 8, 2008 
Harman Multimedia - JBL Radial Micro - EMC Test Report 
2006 100765 EMC Rev.1 
56 of 74 
 
 
8.10.Voltage Dips and Interruptions Immunity Test Results 
 
Client 
Harman Multimedia 
Temperature 81 
deg 
PAN # 
26-765-HAR 
Relative Humidity 
74 
EUT Name 
Speaker System 
Barometric Pressure 
30.21  Hg 
EUT Model  
JBL Radial Micro 
Test Location 
West Ground Plane 
Governing Doc 
EN 55024 
Test Engineer 
Mike Escano 
Basic Standard 
EN 61000-4-11 
Date 
October 31, 2006 
 
 
EUT Voltage: 
X  230VAC @ 50Hz 
 
120VAC @ 60Hz 
 
 
 
 
 
 
Equipment Used Used Asset 
# Cal 
Done Cal 
Due 
California Instruments AC Power 
604 NCR 
NCR 
Xitron 2520 Standard Impedance 
581 1/3/06 
1/3/07 
Xitron 2503AH Power Analysis System 
582 1/3/06 
1/3/07 
EMC Partner Transient 2000 
 
845 3/15/06 
3/15/07 
 
 
 
 
 
 
Changes Occur At: X 
Zero 
Crossing 
   
 
 
 
 
Voltage Dips 
 
 
 
 
Criteria Compliance 
% Reduction Duration 
sec/period 
C Yes No 
  X  >95% 
10msec / 0.5 
 
 
 
   
30% 
10msec / 0.5 
 
 
 
 
 
  X  30% 
500msec / 25 
 
 
 
   
60% 
100msec / 5 
 
 
 
 
 
   
 
 
 
 
 
 
 
   Not 
Required 
 
 
 
 
Voltage Interruptions 
 
 
 
 
Criteria Compliance 
% Reduction Duration 
sec/period 
C Yes No 
  X  >95% 
5000msec / 250 
 
 
 
   
100% 
20msec / 1.0 
 
 
 
 
 
   
 
 
 
 
 
 
 
   Not 
Required 
 
 
 
   
 
 
 
  
 
Photo 
 
 
Page of 74
Display