Harman Multimedia - JBL Radial Micro - EMC Test Report
2006 100765 EMC Rev.1
53 of 74
8.7. Electrical Fast Transient Burst Immunity Test Results
Client
Harman Multimedia
Temperature 5
deg
F
PAN #
26-765-HAR
Relative Humidity
38
%
EUT Name
Speaker System
Barometric Pressure
30.30
Hg
EUT Model
JBL Radial Micro
Test Location
Enclosure 2
Governing Doc
EN 55024
Test Engineer
Mike Escano
Basic Standard
EN 61000-4-4
Date
October 30, 2006
Test Level:
AC / DC Mains / Control Ports
0.5kV
X 1.0kV
2.0kV
4.0kV
______
Signal
Ports
0.25kV 0.5kV 1.0kV
2.0kV ______
Test Duration:
X 61
sec
_______
Test Equipment
Asset # Used Calibration
Done Calibration
Due
Haefely P90.1 Generator
416
X
11/22/05
11/22/06
Haefely 093 506.1 Clamp
417
Haefely FP-EFT Generator 32.1
689
Noiseken FNS-100L
547
Noiseken 15-00001A Clamp
802
NCR
NCR
EMC Partner Transient 2000
845
Performance Criteria:
A
X B
C
Direct Injection Output Path
Test Level
Polarity
(+/-)
L1 L2 PE
Comments
1.0kV +/- X
1.0kV
+/-
X
1.0kV +/- X
X
.5kV +/-
.5kV +/-
.5kV +/-
Cable Description (Clamp Injection) Polarity
Compliant X
Non-Compliant
Photo
X
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
April 8, 2008
Harman Multimedia - JBL Radial Micro - EMC Test Report
2006 100765 EMC Rev.1
54 of 74
8.8. Power Line Surge Immunity Test Results
Client
Harman Multimedia
Temperature 81
deg
F
PAN #
26-765-HAR
Relative Humidity
75
%
EUT Name
Speaker System
Barometric Pressure
30.21 Hg
EUT Model
JBL Radial Micro
Test Location
West Ground Plane
Governing Doc
EN 55024
Test Engineer
Mike Escano
Basic Standard
EN 61000-4-5
Date
October 30, 2006
EUT Power:
Number of Strikes per Polarity/Voltage/Angle
Repetition # Angle
X 230VAC @ 50Hz
X Five (5)
1
0º
230/400VAC @ 50 Hz
Twenty (20)
2
90º
120VAC @ 60 Hz
3
180º
4
270º
Waveform Generator Type:
Ring
Wave X
Combination
Test Equipment: Asset
# Used Calibration
Done Calibration
Due
Haefely PSurge 4010
687
Haefely FP Surge 32.1
688
NCR
NCR
Haefely PC6 288.1
413
Haefely FP Surge 16.1
412
NCR
NCR
EMC Partner Transient 2000
845
X
3/15/06
3/15/07
Performance
Criteria: A X
B C
L - Gnd
0.5kV (Level 1)
1.0kV (Level 2)
2.0kV (Level 3)
4.0kV (Level 4)
??kV (Special)
L - L
X 0.25kV (Level 1) X 0.5kV (Level 2)
X 1.0kV (Level 3)
2.0kV (Level 4)
??kV (Special)
Level 1
Level 2
Level 3
Level 4
Special
CM DM CM DM CM DM CM DM CM DM
0.5kV
0.5kV
0.25kV
1.0kV
0.5kV
2.0kV
1.0kV
4.0kV
2.0kV
+ - + - + - + - + - + - + - + - + - + -
N–Gnd
L1–Gnd
N-L1
X X
X X
X X
Compliant X
Non-Compliant
Photo X
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
April 8, 2008
Harman Multimedia - JBL Radial Micro - EMC Test Report
2006 100765 EMC Rev.1
55 of 74
8.9. RF Conducted Common Mode Disturbance Immunity Test Results
Client
Harman Multimedia
Temperature 77
deg
C
PAN #
26-765-HAR
Relative Humidity
32
%
EUT Name
Speaker System
Barometric Pressure
30.36
Hg
EUT Model
JBL Radial Micro
Test Location
West Ground Plane
Governing Doc
EN 55024
Test Engineer
Mike Escano
Basic Standard
EN 61000-4-6
Date
October 27, 2006
Test Level: X
3Vrms
10Vrms
Modulation:
None (CW)
X 80%AM @ 1kHz
Frequency Range: X
0.15 – 80 MHz
0.15-230MHz
Step: X
1%
10%
1.5 x 10¯³ /decade
Performance Criteria:
A
X B
1 Injection Point (Cable) Power Cord
Injection Method:
Clamp
X CDN
Comments:
Between 15MHz and 42MHz an interruption would occur where the audio would cycle on and
off. However, the EUT would self-recover after the test.
off. However, the EUT would self-recover after the test.
2 Injection Point (Cable) New Power Cord
Injection Method:
Clamp
X CDN
Comments:
Between 14.7MHz and 23.2MHz an interruption would occur where the audio would cycle on and
off. However, the EUT would self-recover after the test.
off. However, the EUT would self-recover after the test.
3 Injection Point (Cable) New Power Cord w/ Ferrite
Injection Method:
Clamp
X CDN
Comments:
From about 13.6MHz to 80MHz, an interruption would occur where the audio would cycle on and
off. However, the EUT would self-recover after the test. At 61MHz, a high pitch noise would
sound.
off. However, the EUT would self-recover after the test. At 61MHz, a high pitch noise would
sound.
4 Injection Point (Cable) New Power Cord
Injection Method:
Clamp
X CDN
Comments:
From about 15MHz to 80MHz, an interruption would occur where the audio would cycle on and
off. However, the EUT would self-recover after the test.
off. However, the EUT would self-recover after the test.
5 Injection Point (Cable) New Power Cord w/ Ferrite
Injection Method
Clamp
X CDN
Comments:
From about 15MHz to 80MHz, an interruption would occur where the audio would cycle on and
off. However, the EUT would self-recover after the test. At 61MHz, a high pitch noise
off. However, the EUT would self-recover after the test. At 61MHz, a high pitch noise
Comments:
The client accepts lower criterion for this test.
Test Equipment Used
Asset #
X if Used Calibration
Done Calibration
Due
HP 8462B (Signal Generator)
751
Fluke 6060B (Signal Generator)
212
HP 8648B (Signal Generator)
746
X
10/31/05
10/31/06
FCC-801-M1-25 (CDN)
473
FCC-801-M2-25 (CDN)
472
X
10/02/06
10/02/07
FCC-801-M3-25A (CDN)
846
FCC-801-M4-25 (CDN)
628
FCC-801-M5-25 (CDN)
629
FCC-801-T2 (CDN)
626
FCC-801-T4 (CDN)
627
Amplifier 3100L
913
X
8/11/06
8/11/07
IFI 1500 (Amplifier)
571
NCR
NCR
RF Power Labs (Amplifier)
397
NCR
NCR
Solar 9144-1N (Clamp)
436
Solar 9121-1N (Clamp)
435
Compliant
Non-Compliant
X
Photo X
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
April 8, 2008
Harman Multimedia - JBL Radial Micro - EMC Test Report
2006 100765 EMC Rev.1
56 of 74
8.10.Voltage Dips and Interruptions Immunity Test Results
Client
Harman Multimedia
Temperature 81
deg
F
PAN #
26-765-HAR
Relative Humidity
74
%
EUT Name
Speaker System
Barometric Pressure
30.21 Hg
EUT Model
JBL Radial Micro
Test Location
West Ground Plane
Governing Doc
EN 55024
Test Engineer
Mike Escano
Basic Standard
EN 61000-4-11
Date
October 31, 2006
EUT Voltage:
X 230VAC @ 50Hz
120VAC @ 60Hz
Equipment Used Used Asset
# Cal
Done Cal
Due
California Instruments AC Power
X
604 NCR
NCR
Xitron 2520 Standard Impedance
X
581 1/3/06
1/3/07
Xitron 2503AH Power Analysis System
X
582 1/3/06
1/3/07
EMC Partner Transient 2000
845 3/15/06
3/15/07
Changes Occur At: X
Zero
Crossing
Voltage Dips
Criteria Compliance
% Reduction Duration
sec/period
A
B
C Yes No
X >95%
10msec / 0.5
X
X
30%
10msec / 0.5
X 30%
500msec / 25
X
X
60%
100msec / 5
Not
Required
Voltage Interruptions
Criteria Compliance
% Reduction Duration
sec/period
A
B
C Yes No
X >95%
5000msec / 250
X
X
100%
20msec / 1.0
Not
Required