JBL RADIAL MICRO (serv.man3) EMC - CB Certificate ▷ View online
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
April 8, 2008
Harman Multimedia - JBL Radial Micro - EMC Test Report
2006 100765 EMC Rev.1
21 of 74
Figure 4. ESD Test Setup Diagram
N
OT TO
S
CALE
CONFIGURATION LEGEND
1. Test Laboratory (6 x 7 meters)
2. Vertical Conducting Wall (3 x 3 m, grounded)
3. Ground Plane (14 square meters)
4. Ground Rod extending 3 m under ground plane
5. Non-Conducting table for ESD Simulator Control Box
6. ESD Simulator Control Box on cart
7. Electro-Static Discharge (ESD) Gun (hand held, grounded to grounding rod)
8. DC power for devices
9. Ground strap with two 470kOhm resistors
10. Grounding Strap
11. Horizontal Coupling Plane, grounded to Grounding Rod
12. Insulating Mat
13. Vertical Coupling Plane
14. EUT and Associated System
1
2
3
4
6
7
5
8
9
11
12
10
13
14
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
April 8, 2008
Harman Multimedia - JBL Radial Micro - EMC Test Report
2006 100765 EMC Rev.1
22 of 74
4.8. Radio Frequency Immunity: IEC 61000-4-3: 2006
This test bombards the EUT with electric fields that may couple into the system via chassis slots and interface
cables and evaluates the product’s immunity. Testing was performed in accordance with IEC 61000-4-3. The
RF immunity test entails subjecting the equipment under test to a uniform field of radiated electromagnetic
energy of a specified field strength and frequency, and monitoring the functionality of the device as the
frequency is swept over a specified frequency range.
The EUT is set up inside a shielded, semi-anechoic chamber with a radiating antenna at a distance of 3 meters
from the EUT. For further information, please refer to the technical sections in the IEC 61000-4-3 publication
in addition to the test results section and photographs of the test set-up provided in this report.
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
April 8, 2008
Harman Multimedia - JBL Radial Micro - EMC Test Report
2006 100765 EMC Rev.1
23 of 74
Figure 5. Radio Frequency Immunity Test Setup Diagram
NOT TO SCALE
CONFIGURATION LEGEND
1. Test
laboratory
2. Shielded anechoic chamber
3. Power Line filters and power distribution breaker box
4. Power strip for EUT and peripherals
5. Transmit
3. Power Line filters and power distribution breaker box
4. Power strip for EUT and peripherals
5. Transmit
antennas
6. E-Field
sensor
7. Monitoring camera for EUT
8. Broadband power amplifiers
9. E-Field probe monitoring system
10. Signal Generators
11. Non-Conducting table
12. EUT and Associated System
8. Broadband power amplifiers
9. E-Field probe monitoring system
10. Signal Generators
11. Non-Conducting table
12. EUT and Associated System
1
3
3 m
2
4
5
7
8
9
10
11
12
6
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
April 8, 2008
Harman Multimedia - JBL Radial Micro - EMC Test Report
2006 100765 EMC Rev.1
24 of 74
4.9. Electrical Fast Transient Immunity: IEC 61000-4-4: 2004
This test injects a transient/burst interference onto the AC/DC power supply and signal I/O lines. Testing was
performed in accordance with IEC 61000-4-4. The standard configuration for “type tests” outlined in IEC
61000-4-4 is used. For further information, please refer to the technical sections in the IEC 61000-4-4 in
addition to the test results section and photographs of the test set-up provided in this report.