DOWNLOAD JBL RADIAL MICRO (serv.man3) Service Manual ↓ Size: 2.37 MB | Pages: 74 in PDF or view online for FREE

Model
RADIAL MICRO (serv.man3)
Pages
74
Size
2.37 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
radial-micro-sm3.pdf
Date

JBL RADIAL MICRO (serv.man3) EMC - CB Certificate ▷ View online

Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
April 8, 2008 
Harman Multimedia - JBL Radial Micro - EMC Test Report 
2006 100765 EMC Rev.1 
5 of 74 
 
 
CERTIFICATION 
 
The compatibility testing and this report have been prepared by Nemko USA, Inc., an independent 
electromagnetic compatibility consulting and test laboratory.   
 
Testing and data collection were accomplished in accordance with the test methods listed in this report. 
 
I certify the data evaluation and equipment configuration herein to be a true and accurate representation of the 
sample's test characteristics, as of the test date(s), and for the design of the test sample utilized to compile this 
report. 
 
 
Michael T. Krumweide 
EMC Supervisor 
 
Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
April 8, 2008 
Harman Multimedia - JBL Radial Micro - EMC Test Report 
2006 100765 EMC Rev.1 
6 of 74 
 
1.  ADMINISTRATIVE DATA AND TEST SUMMARY 
1.1. Administrative Data 
 
CLIENT: Harman 
Multimedia
 
 
CONTACT: Bruce 
Ryan 
 
DATE (S) OF TEST: 
August 21, 2006 to November 1, 2006 
 
EQUIPMENT UNDER TEST (EUT): 
Speaker System 
 
 
M
ODEL
 
JBL Radial Micro 
 
 
 
 
C
ONDITION 
U
PON 
R
ECEIPT
 
Suitable for Test 
 
TEST SPECIFICATION: 
Radio Frequency Emissions in accordance with requirements 
of EN 55022: 2006 and FCC Part 15B, which also meets 
Industry Canada's ICES-003 standard for unintentional 
radiating device per EMCAB-4, Issue 3 (December 
2005).Electromagnetic Immunity tests in accordance with 
requirements of EN 55024: 1998/A1: 2001/A2: 2003 
 
Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
April 8, 2008 
Harman Multimedia - JBL Radial Micro - EMC Test Report 
2006 100765 EMC Rev.1 
7 of 74 
 
1.2. Test Summary 
1.2.1.  Emissions Test Summary 
 
Test Methods 
Frequency Range 
Compliance Status 
FCC 15B, Sec. 107, Class “B” 
Conducted Emissions  
0.15 MHz – 30 MHz  
PASS 
FCC 15B, Sec. 109, Class “B” 
Radiated Emissions  
30 MHz –1000MHz  
PASS 
VCCI, V-3/2006.04, 
Normative Annex 1, Class “B” 
Conducted Emissions  
0.15 MHz – 30 MHz  
PASS 
VCCI, V-3/2006.04, 
Normative Annex 1, Class “B” 
Radiated Emissions  
30 MHz – 1000 MHz  
PASS 
EN 55022: 2006, Class “B” 
Conducted Emissions  
0.15 MHz – 30 MHz  
PASS 
EN 55022: 2006, Class “B” 
Telecom Conducted Emissions  
0.15 MHz – 30 MHz  
N/A 
EN 55022: 2006, Class “B” 
Radiated Emissions  
30 MHz – 1000 MHz  
PASS 
EN 61000-3-2: 2000/A2: 2005 
Power Line Harmonics 
up to the 40
th
 Harmonic 
PASS 
EN 61000-3-3: 1995/A1: 
2001Power Line Flicker 
less than or equal to
 4% Maximum Relative 
Voltage Change;  Value of D(T) 
less than or equal 
to
 3% for more than 200 Ms 
PASS 
 
 
 
Test Supervisor: 
 
Mike Krumweide, Nemko USA, Inc. 
 
Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
April 8, 2008 
Harman Multimedia - JBL Radial Micro - EMC Test Report 
2006 100765 EMC Rev.1 
8 of 74 
 
 
1.2.2.  Immunity Test Summary 
 
 
Test Methods 
 
Minimum Criterion  
Level Required  
as per EN 55024 
 
Criterion Level 
Tested 
Compliance 
Status 
IEC 61000-4-2: 1995/A1: 
1998/A2: 2000
 
- ESD Immunity 
Criterion B 
±8 kV air discharge,  
±4 kV contact discharge 
Criterion B 
±8 kV Air Discharge,  
±4 kV Contact Discharge 
PASS 
IEC 61000-4-3: 2006 -
Radio Frequency 
Immunity 
Criterion A  
3 V/m from 80-1000 MHz  
(80% AM at 1kHz) 
Criterion A  
3 V/m from 80-6000 MHz  
(80% AM at 1kHz) 
PASS 
IEC 61000-4-4: 2004 
-Electrical Fast Transient 
Immunity 
Criterion B 
Power line pulses of ± 1 kV; 
I/O line pulses of ± 0.5 kV 
Criterion B 
Power Line Pulses of ± 1 kV; 
up to ±2kV process/control lines; 
I/O Line Pulses of ± 0.5 kV 
PASS 
IEC 61000-4-5: 2005 
-Surge Immunity 
Criterion B 
±2kV common mode surges, 
±1kV differential mode surges 
Criterion B 
±2kV Common Mode Surges,  
±1kV Differential Mode 
Surges 
PASS 
IEC 61000-4-6: 2003/A1: 
2004/A2: 2006 
-RF Common Mode 
Immunity 
Criterion A 
150 kHz - 80 MHz at 3 Vrms 
1 kHz 80% amplitude modulated 
Criterion B 
150 kHz - 80 MHz at 3 Vrms 
1kHz 80% amplitude modulated 
*
PASS 
IEC 61000-4-8: 1993/A1: 
2000
 
Power Frequency Magnetic 
Field 
Criterion A 
Helmholtz coil at 50 Hz, 
to 1 Amp (rms) per meter 
Criterion A 
Helmholtz coil at 50 Hz, 
to 1 Amp (rms) per meter 
Not Required 
 
IEC 61000-4-11: 2004 
- Voltage Dips and Short 
Interruptions 
Criterion B and C 
Voltage Dips of 30% and >95%; 
Interruptions of >95%. 
Criterion B and C 
Voltage Dips of 30% and 
>95%; Interruptions of >95%. 
PASS 
*
 Client accepts a lowered criterion for this test. 
 
 
Test Supervisor
 
Mike Krumweide, Nemko USA, Inc. 
Refer to the test results section for further details
Page of 74
Display