JBL RADIAL MICRO (serv.man3) EMC - CB Certificate ▷ View online
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
April 8, 2008
Harman Multimedia - JBL Radial Micro - EMC Test Report
2006 100765 EMC Rev.1
5 of 74
CERTIFICATION
The compatibility testing and this report have been prepared by Nemko USA, Inc., an independent
electromagnetic compatibility consulting and test laboratory.
Testing and data collection were accomplished in accordance with the test methods listed in this report.
I certify the data evaluation and equipment configuration herein to be a true and accurate representation of the
sample's test characteristics, as of the test date(s), and for the design of the test sample utilized to compile this
report.
Michael T. Krumweide
EMC Supervisor
EMC Supervisor
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
April 8, 2008
Harman Multimedia - JBL Radial Micro - EMC Test Report
2006 100765 EMC Rev.1
6 of 74
1. ADMINISTRATIVE DATA AND TEST SUMMARY
1.1. Administrative Data
CLIENT: Harman
Multimedia
CONTACT: Bruce
Ryan
DATE (S) OF TEST:
August 21, 2006 to November 1, 2006
EQUIPMENT UNDER TEST (EUT):
Speaker System
M
ODEL
JBL Radial Micro
C
ONDITION
U
PON
R
ECEIPT
Suitable for Test
TEST SPECIFICATION:
Radio Frequency Emissions in accordance with requirements
of EN 55022: 2006 and FCC Part 15B, which also meets
Industry Canada's ICES-003 standard for unintentional
radiating device per EMCAB-4, Issue 3 (December
2005).Electromagnetic Immunity tests in accordance with
requirements of EN 55024: 1998/A1: 2001/A2: 2003
Industry Canada's ICES-003 standard for unintentional
radiating device per EMCAB-4, Issue 3 (December
2005).Electromagnetic Immunity tests in accordance with
requirements of EN 55024: 1998/A1: 2001/A2: 2003
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
April 8, 2008
Harman Multimedia - JBL Radial Micro - EMC Test Report
2006 100765 EMC Rev.1
7 of 74
1.2. Test Summary
1.2.1. Emissions Test Summary
Test Methods
Frequency Range
Compliance Status
FCC 15B, Sec. 107, Class “B”
Conducted Emissions
Conducted Emissions
0.15 MHz – 30 MHz
PASS
FCC 15B, Sec. 109, Class “B”
Radiated Emissions
Radiated Emissions
30 MHz –1000MHz
PASS
VCCI, V-3/2006.04,
Normative Annex 1, Class “B”
Conducted Emissions
Normative Annex 1, Class “B”
Conducted Emissions
0.15 MHz – 30 MHz
PASS
VCCI, V-3/2006.04,
Normative Annex 1, Class “B”
Radiated Emissions
Normative Annex 1, Class “B”
Radiated Emissions
30 MHz – 1000 MHz
PASS
EN 55022: 2006, Class “B”
Conducted Emissions
Conducted Emissions
0.15 MHz – 30 MHz
PASS
EN 55022: 2006, Class “B”
Telecom Conducted Emissions
Telecom Conducted Emissions
0.15 MHz – 30 MHz
N/A
EN 55022: 2006, Class “B”
Radiated Emissions
Radiated Emissions
30 MHz – 1000 MHz
PASS
EN 61000-3-2: 2000/A2: 2005
Power Line Harmonics
up to the 40
th
Harmonic
PASS
EN 61000-3-3: 1995/A1:
2001Power Line Flicker
2001Power Line Flicker
less than or equal to
4% Maximum Relative
Voltage Change; Value of D(T)
less than or equal
to
3% for more than 200 Ms
PASS
Test Supervisor:
Mike Krumweide, Nemko USA, Inc.
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
April 8, 2008
Harman Multimedia - JBL Radial Micro - EMC Test Report
2006 100765 EMC Rev.1
8 of 74
1.2.2. Immunity Test Summary
Test Methods
Minimum Criterion
Level Required
as per EN 55024
Criterion Level
Tested
Compliance
Status
IEC 61000-4-2: 1995/A1:
1998/A2: 2000
1998/A2: 2000
- ESD Immunity
Criterion B
±8 kV air discharge,
±4 kV contact discharge
Criterion B
±8 kV Air Discharge,
±4 kV Contact Discharge
PASS
IEC 61000-4-3: 2006 -
Radio Frequency
Immunity
Immunity
Criterion A
3 V/m from 80-1000 MHz
(80% AM at 1kHz)
Criterion A
3 V/m from 80-6000 MHz
(80% AM at 1kHz)
PASS
IEC 61000-4-4: 2004
-Electrical Fast Transient
-Electrical Fast Transient
Immunity
Criterion B
Power line pulses of ± 1 kV;
I/O line pulses of ± 0.5 kV
Criterion B
Power Line Pulses of ± 1 kV;
up to ±2kV process/control lines;
I/O Line Pulses of ± 0.5 kV
PASS
IEC 61000-4-5: 2005
-Surge Immunity
-Surge Immunity
Criterion B
±2kV common mode surges,
±1kV differential mode surges
Criterion B
±2kV Common Mode Surges,
±1kV Differential Mode
Surges
PASS
IEC 61000-4-6: 2003/A1:
2004/A2: 2006
-RF Common Mode
2004/A2: 2006
-RF Common Mode
Immunity
Criterion A
150 kHz - 80 MHz at 3 Vrms
1 kHz 80% amplitude modulated
Criterion B
150 kHz - 80 MHz at 3 Vrms
1kHz 80% amplitude modulated
*
PASS
IEC 61000-4-8: 1993/A1:
2000
Power Frequency Magnetic
Field
Field
Criterion A
Helmholtz coil at 50 Hz,
to 1 Amp (rms) per meter
Criterion A
Helmholtz coil at 50 Hz,
to 1 Amp (rms) per meter
Not Required
IEC 61000-4-11: 2004
- Voltage Dips and Short
- Voltage Dips and Short
Interruptions
Criterion B and C
Voltage Dips of 30% and >95%;
Interruptions of >95%.
Criterion B and C
Voltage Dips of 30% and
>95%; Interruptions of >95%.
PASS
*
Client accepts a lowered criterion for this test.
Test Supervisor:
Mike Krumweide, Nemko USA, Inc.
Refer to the test results section for further details.