JBL PULSE (serv.man6) EMC - CB Certificate ▷ View online
Page 21 of 51
Report No. 241619
IEC
60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1C
2.10.5.7
Separable thin sheet material
N/A
Number of layers (pcs) ........................................... :
—
2.10.5.8
Non-separable thin sheet material
N/A
2.10.5.9
Thin sheet material – standard test procedure
N/A
Electric strength test
—
2.10.5.10
Thin sheet material – alternative test procedure
N/A
Electric strength test
—
2.10.5.11
Insulation in wound components
N/A
2.10.5.12
Wire in wound components
N/A
Working
voltage .................................................... :
N/A
a) Basic insulation not under stress ...................... :
N/A
b) Basic, supplementary, reinforced insulation ..... :
N/A
c) Compliance with Annex U ................................. :
N/A
Two wires in contact inside wound component;
angle between 45
angle between 45
and 90 ................................... :
N/A
2.10.5.13
Wire with solvent-based enamel in wound
components
components
N/A
Electric strength test
N/A
Routine test
N/A
2.10.5.14
Additional insulation in wound components
N/A
Working
voltage .................................................... :
N/A
- Basic insulation not under stress ........................ :
N/A
- Supplementary, reinforced insulation ................. :
N/A
2.10.6
Construction of printed boards
—
2.10.6.1
Uncoated printed boards
N/A
2.10.6.2
Coated printed boards
N/A
2.10.6.3
Insulation between conductors on the same inner
surface of a printed board
surface of a printed board
N/A
2.10.6.4
Insulation between conductors on different layers
of a printed board
of a printed board
N/A
Distance through insulation
N/A
Number of insulation layers (pcs) ..........................
:
—
2.10.7
Component external terminations
N/A
2.10.8
Tests on coated printed boards and coated
components
components
N/A
Page 22 of 51
Report No. 241619
IEC
60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1C
2.10.8.1
Sample preparation and preliminary inspection
N/A
2.10.8.2 Thermal
conditioning
N/A
2.10.8.3
Electric strength test
N/A
2.10.8.4
Abrasion resistance test
N/A
2.10.9 Thermal
cycling
N/A
2.10.10
Test for Pollution Degree 1 environment and
insulating compound
insulating compound
N/A
2.10.11
Tests for semiconductor devices and cemented
joints
joints
N/A
2.10.12
Enclosed and sealed parts
N/A
3
WIRING, CONNECTIONS AND SUPPLY
P
3.1 General
N/A
3.1.1
Current rating and overcurrent protection
Class III equipment.
N/A
3.1.2
Protection against mechanical damage
N/A
3.1.3
Securing of internal wiring
N/A
3.1.4
Insulation of conductors
N/A
3.1.5
Beads and ceramic insulators
N/A
3.1.6
Screws for electrical contact pressure
N/A
3.1.7
Insulating materials in electrical connections
No contact pressure through
insulating material.
insulating material.
N/A
3.1.8
Self-tapping and spaced thread screws
Thread-cutting or space
thread screws are not used
for electrical connections.
thread screws are not used
for electrical connections.
P
3.1.9
Termination of conductors
No such device in the
equipment.
equipment.
N/A
10 N pull test
N/A
3.1.10
Sleeving on wiring
No sleeving on wire.
N/A
3.2
Connection to a mains supply
N/A
3.2.1
Means of connection
Class III equipment.
—
3.2.1.1
Connection to an a.c. mains supply
N/A
3.2.1.2
Connection to a d.c. mains supply
N/A
3.2.2
Multiple supply connections
N/A
3.2.3
Permanently connected equipment
N/A
Page 23 of 51
Report No. 241619
IEC
60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1C
Number of conductors, diameter of cable and
conduits (mm) ....................................................... :
conduits (mm) ....................................................... :
—
3.2.4 Appliance
inlets
N/A
3.2.5
Power supply cords
—
3.2.5.1
AC power supply cords
N/A
Type
......................................................................
:
—
Rated current (A), cross-sectional area (mm
2
),
AWG ...................................................................... :
—
3.2.5.2
DC power supply cords
N/A
3.2.6
Cord anchorages and strain relief
N/A
Mass of equipment (kg), pull (N) .......................... :
Longitudinal
displacement (mm) ........................... :
3.2.7
Protection against mechanical damage
N/A
3.2.8 Cord
guards
N/A
Diameter or minor dimension D (mm); test mass (g)
............................................................................... :
............................................................................... :
Radius of curvature of cord (mm) .......................... :
3.2.9
Supply wiring space
N/A
3.3
Wiring terminals for connection of external conductors
N/A
3.3.1
Wiring terminals
Class III equipment.
N/A
3.3.2
Connection of non-detachable power supply cords
N/A
3.3.3 Screw
terminals
N/A
3.3.4
Conductor sizes to be connected
N/A
Rated current (A), cord/cable type, cross-sectional
area (mm
area (mm
2
) ............................................................. :
3.3.5
Wiring terminal sizes
N/A
Rated current (A), type, nominal thread diameter
(mm) ...................................................................... :
(mm) ...................................................................... :
3.3.6
Wiring terminal design
N/A
3.3.7
Grouping of wiring terminals
N/A
3.3.8 Stranded
wire
N/A
3.4
Disconnection from the mains supply
N/A
3.4.1
General requirement
Class III equipment.
N/A
Page 24 of 51
Report No. 241619
IEC
60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1C
3.4.2 Disconnect
devices
N/A
3.4.3
Permanently connected equipment
N/A
3.4.4
Parts which remain energized
N/A
3.4.5
Switches in flexible cords
3.4.6
Number of poles - single-phase and d.c. equipment
N/A
3.4.7
Number of poles - three-phase equipment
N/A
3.4.8
Switches as disconnect devices
N/A
3.4.9
Plugs as disconnect devices
N/A
3.4.10 Interconnected
equipment
N/A
3.4.11
Multiple power sources
N/A
3.5
Interconnection of equipment
P
3.5.1 General
requirements
Considered.
—
3.5.2
Types of interconnection circuits .......................... : SELV circuit.
P
3.5.3
ELV circuits as interconnection circuits
No ELV.
N/A
3.5.4
Data ports for additional equipment
The USB port used for
charging battery within
equipmemt only, it is
downstream in one way and
no power supply outside.
charging battery within
equipmemt only, it is
downstream in one way and
no power supply outside.
P
4 PHYSICAL
REQUIREMENTS
P
4.1 Stability
N/A
Angle of 10
Mass < 7kg
N/A
Test force (N) ........................................................ : The unit is not floor-standing.
N/A
4.2 Mechanical
strength
P
4.2.1
General
Complies with the
requirement also after tests
described below are applied.
requirement also after tests
described below are applied.
P
Rack-mounted equipment.
Not rack-mounted equipment.
N/A
4.2.2
Steady force test, 10 N
Class III equipment.
N/A
4.2.3
Steady force test, 30 N
No hazard. The test is
performed at internal
enclosure.
performed at internal
enclosure.
P
Click on the first or last page to see other PULSE (serv.man6) service manuals if exist.