JBL PULSE (serv.man6) EMC - CB Certificate ▷ View online
Page 29 of 51
Report No. 241619
IEC
60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1C
4.7.3.3
Materials for components and other parts outside
fire enclosures
fire enclosures
Considered. P
4.7.3.4
Materials for components and other parts inside
fire enclosures
fire enclosures
Other materials inside fire
enclosure are min. V-2
material.
enclosure are min. V-2
material.
P
4.7.3.5
Materials for air filter assemblies
No air filters in the equipment.
N/A
4.7.3.6
Materials used in high-voltage components
No parts exceeding 4kV.
N/A
5
ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS
P
5.1
Touch current and protective conductor current
N/A
5.1.1
General
Class III equipment.
N/A
5.1.2
Configuration of equipment under test (EUT)
—
5.1.2.1
Single connection to an a.c. mains supply
N/A
5.1.2.2
Redundant multiple connections to an a.c. mains
supply
supply
N/A
5.1.2.3
Simultaneous multiple connections to an a.c. mains
supply
supply
N/A
5.1.3 Test
circuit
N/A
5.1.4
Application of measuring instrument
N/A
5.1.5 Test
procedure
—
5.1.6 Test
measurements
—
Supply
voltage (V) ................................................ :
—
Measured touch current (mA) .............................. :
—
Max. allowed touch current (mA) ......................... :
—
Measured protective conductor current (mA) ...... :
—
Max. allowed protective conductor current (mA) .. :
—
5.1.7
Equipment with touch current exceeding 3,5 mA
N/A
5.1.7.1 General ................................................................. :
—
5.1.7.2
Simultaneous multiple connections to the supply
N/A
5.1.8
Touch currents to telecommunication networks and
cable distribution systems and from
telecommunication networks
cable distribution systems and from
telecommunication networks
Not connected to a
telecommunication network
nor a cable distribution
system.
telecommunication network
nor a cable distribution
system.
N/A
5.1.8.1
Limitation of the touch current to a
telecommunication network or to a cable
distribution system
telecommunication network or to a cable
distribution system
N/A
Supply
voltage (V) ................................................ :
—
Page 30 of 51
Report No. 241619
IEC
60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1C
Measured touch current (mA) .............................. :
—
Max. allowed touch current (mA) ......................... :
—
5.1.8.2
Summation of touch currents from
telecommunication networks
telecommunication networks
N/A
a) EUT with earthed telecommunication ports ..... :
—
b) EUT whose telecommunication ports have no
reference to protective earth
reference to protective earth
—
5.2 Electric
strength
N/A
5.2.1
General
Class III equipment.
N/A
5.2.2
Test procedure
N/A
5.3
Abnormal operating and fault conditions
P
5.3.1
Protection against overload and abnormal
operation
operation
(see appended table 5.3)
P
5.3.2
Motors
There is no motors on the
equipment.
equipment.
N/A
5.3.3
Transformers
No isolating transformer in the
equipment.
equipment.
N/A
5.3.4 Functional
insulation
............................................. :
Complies with c).
P
5.3.5
Electromechanical components
No electromechanical
components in secondary
circuits.
components in secondary
circuits.
N/A
5.3.6
Audio amplifiers in ITE ......................................... :
Considered, the speaker is
adjusted to max. volume
during the test.
adjusted to max. volume
during the test.
P
5.3.7
Simulation of faults
(see appended table 5.3)
P
5.3.8 Unattended
equipment
No
thermostats, temperature
limiters or thermal cut-outs.
N/A
5.3.9
Compliance criteria for abnormal operating and
fault conditions
fault conditions
See below.
P
5.3.9.1
During the tests
No fire or molten metal
occurred and no deformation
of enclosure during the tests.
occurred and no deformation
of enclosure during the tests.
P
5.3.9.2
After the tests
No fire or molten metal
occurred and no deformation
of enclosure during the tests.
occurred and no deformation
of enclosure during the tests.
P
Page 31 of 51
Report No. 241619
IEC
60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1C
6
CONNECTION TO TELECOMMUNICATION NETWORKS
N/A
6.1
Protection of telecommunication network service persons, and users of other
equipment connected to the network, from hazards in the equipment
equipment connected to the network, from hazards in the equipment
6.1.1
Protection from hazardous voltages
6.1.2
Separation of the telecommunication network from earth
6.1.2.1
Requirements
No TNV circuit.
N/A
Supply
voltage
(V) ................................................ :
Current in the test circuit (mA) ........................... :
6.1.2.2 Exclusions ............................................................ :
N/A
6.2
Protection of equipment users from overvoltages on telecommunication
networks
networks
N/A
6.2.1 Separation
requirements
N/A
6.2.2
Electric strength test procedure
N/A
6.2.2.1 Impulse
test
N/A
6.2.2.2 Steady-state
test
N/A
6.2.2.3 Compliance
criteria
N/A
6.3
Protection of the telecommunication wiring system from overheating
N/A
Max. output current (A) ........................................ :
Current
limiting method ........................................ :
7
CONNECTION TO CABLE DISTRIBUTION SYSTEMS
7.1
General
Not connected to Cable
Distribution System.
Distribution System.
N/A
7.2
Protection of cable distribution system service
persons, and users of other equipment connected
to the system, from hazardous voltages in the
equipment
persons, and users of other equipment connected
to the system, from hazardous voltages in the
equipment
N/A
7.3
Protection of equipment users from overvoltages
on the cable distribution system
on the cable distribution system
N/A
7.4
Insulation between primary circuits and cable
distribution systems
distribution systems
N/A
7.4.1 General
N/A
7.4.2
Voltage surge test
N/A
7.4.3 Impulse
test
N/A
Page 32 of 51
Report No. 241619
IEC
60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1C
A
ANNEX A, TESTS FOR RESISTANCE TO HEAT AND FIRE
N/A
A.1
Flammability test for fire enclosures of movable
equipment having a total mass exceeding 18 kg,
and of stationary equipment (see 4.7.3.2)
equipment having a total mass exceeding 18 kg,
and of stationary equipment (see 4.7.3.2)
Not used.
N/A
A.1.1 Samples
................................................................
:
Wall
thickness (mm) .............................................. :
A.1.2
Conditioning of samples; temperature (
C) ......... : N/A
A.1.3
Mounting of samples ............................................ :
N/A
A.1.4
Test flame (see IEC 60695-11-3)
N/A
Flame A, B, C or D ............................................... :
A.1.5 Test
procedure
N/A
A.1.6 Compliance
criteria
N/A
Sample 1 burning time (s) ..................................... :
Sample 2 burning time (s) ..................................... :
Sample 3 burning time (s) ..................................... :
A.2
Flammability test for fire enclosures of movable equipment having a total mass not
exceeding 18 kg, and for material and components located inside fire enclosures
(see 4.7.3.2 and 4.7.3.4)
exceeding 18 kg, and for material and components located inside fire enclosures
(see 4.7.3.2 and 4.7.3.4)
N/A
A.2.1 Samples,
material ................................................. :
Wall
thickness (mm) .............................................. :
A.2.2
Conditioning of samples; temperature (°C) ......... :
N/A
A.2.3
Mounting of samples ............................................ :
N/A
A.2.4
Test flame (see IEC 60695-11-4)
N/A
Flame A, B or C .................................................... :
A.2.5 Test
procedure
N/A
A.2.6 Compliance
criteria
N/A
Sample 1 burning time (s) ..................................... :
Sample 2 burning time (s) ..................................... :
Sample 3 burning time (s) ..................................... :
A.2.7
Alternative test acc. to IEC 60695-11-5, cl. 5 and 9
N/A
Sample 1 burning time (s) ..................................... :
Sample 2 burning time (s) ..................................... :
Sample 3 burning time (s) ..................................... :
A.3
Hot flaming oil test (see 4.6.2)
N/A