JBL PULSE (serv.man6) EMC - CB Certificate ▷ View online
Page 17 of 51
Report No. 241619
IEC
60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1C
2.4.1
General requirements
No limited current circuit.
N/A
2.4.2 Limit
values
N/A
Frequency
(Hz) ...................................................... :
—
Measured
current (mA) .......................................... :
—
Measured
voltage (V) ............................................. :
—
Measured circuit capacitance (nF or µF) ............... :
—
2.4.3
Connection of limited current circuits to other
circuits
circuits
N/A
2.5
Limited power sources
N/A
a) Inherently limited output
This class III product supplied
by certificated adapter which
comply with LPS.
by certificated adapter which
comply with LPS.
N/A
b) Impedance limited output
N/A
c) Regulating network limited output under normal
operating and single fault condition
operating and single fault condition
N/A
d) Overcurrent protective device limited output
N/A
Max. output voltage (V), max. output current (A),
max. apparent power (VA) ..................................... :
max. apparent power (VA) ..................................... :
Current rating of overcurrent protective device (A) .:
Use of integrated circuit (IC) current limiters
N/A
2.6
Provisions for earthing and bonding
N/A
2.6.1
Protective earthing
Class III equipment.
N/A
2.6.2
Functional earthing
Class III equipment.
N/A
2.6.3
Protective earthing and protective bonding
conductors
conductors
Class III equipment.
—
2.6.3.1
General
Class III equipment.
—
2.6.3.2
Size of protective earthing conductors
Class III equipment.
N/A
Rated current (A), cross-sectional area (mm
2
),
AWG ....................................................................... :
—
2.6.3.3
Size of protective bonding conductors
Class III equipment.
N/A
Rated current (A), cross-sectional area (mm
2
),
AWG ....................................................................... :
—
Protective current rating (A), cross-sectional area
(mm
(mm
2
), AWG ........................................................... :
—
Page 18 of 51
Report No. 241619
IEC
60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1C
2.6.3.4
Resistance of earthing conductors and their
terminations; resistance (
terminations; resistance (
), voltage drop (V), test
current (A), duration (min) ...................................... :
Class III equipment.
N/A
2.6.3.5
Colour of insulation ................................................ : No such part.
N/A
2.6.4 Terminals
Refer
below:
—
2.6.4.1 General
Refer
below:
—
2.6.4.2
Protective earthing and bonding terminals
Refer below:
—
Rated current (A), type, nominal thread diameter
(mm) ....................................................................... :
(mm) ....................................................................... :
N/A
2.6.4.3
Separation of the protective earthing conductor
from protective bonding conductors
from protective bonding conductors
N/A
2.6.5
Integrity of protective earthing
N/A
2.6.5.1
Interconnection of equipment
N/A
2.6.5.2
Components in protective earthing conductors and
protective bonding conductors
protective bonding conductors
N/A
2.6.5.3
Disconnection of protective earth
N/A
2.6.5.4
Parts that can be removed by an operator
No operator removable parts
with protective earth
connection except supply
cord.
with protective earth
connection except supply
cord.
N/A
2.6.5.5 Parts
removed
during servicing
N/A
2.6.5.6 Corrosion
resistance
No risk of corrosion.
N/A
2.6.5.7
Screws for protective bonding
N/A
2.6.5.8
Reliance on telecommunication network or cable
distribution system
distribution system
N/A
2.7
Overcurrent and earth fault protection in primary circuits
N/A
2.7.1
Basic requirements
Class III equipment.
N/A
Instructions when protection relies on building
installation
installation
N/A
2.7.2
Faults not simulated in 5.3.7
N/A
2.7.3
Short-circuit backup protection
N/A
2.7.4
Number and location of protective devices ........... :
N/A
2.7.5
Protection by several devices
N/A
2.7.6
Warning to service personnel ................................ :
N/A
2.8 Safety
interlocks
N/A
Page 19 of 51
Report No. 241619
IEC
60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1C
2.8.1
General principles
No safety interlocks.
N/A
2.8.2 Protection
requirements
N/A
2.8.3 Inadvertent
reactivation
N/A
2.8.4 Fail-safe
operation
N/A
Protection against extreme hazard
N/A
2.8.5 Moving
parts
N/A
2.8.6 Overriding
N/A
2.8.7
Switches, relays and their related circuits
N/A
2.8.7.1 Separation
distances for contact gaps and their
related circuits (mm) ............................................. :
N/A
2.8.7.2 Overload
test
N/A
2.8.7.3 Endurance
test
N/A
2.8.7.4
Electric strength test
N/A
2.8.8 Mechanical
actuators
N/A
2.9 Electrical
insulation
N/A
2.9.1
Properties of insulating materials
Class III equipment.
N/A
2.9.2 Humidity
conditioning
N/A
Relative humidity (%), temperature (°C) ............... :
—
2.9.3
Grade of insulation
N/A
2.9.4
Separation from hazardous voltages
N/A
Method(s)
used ..................................................... :
—
2.10
Clearances, creepage distances and distances through insulation
N/A
2.10.1
General
Class III equipment.
N/A
2.10.1.1 Frequency ............................................................. :
N/A
2.10.1.2 Pollution
degrees .................................................. :
N/A
2.10.1.3
Reduced values for functional insulation
N/A
2.10.1.4
Intervening unconnected conductive parts
—
2.10.1.5
Insulation with varying dimensions
N/A
2.10.1.6 Special
separation requirements
N/A
2.10.1.7
Insulation in circuits generating starting pulses
N/A
2.10.2
Determination of working voltage
N/A
Page 20 of 51
Report No. 241619
IEC
60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1C
2.10.2.1 General
N/A
2.10.2.2
RMS working voltage
N/A
2.10.2.3
Peak working voltage
N/A
2.10.3 Clearances
N/A
2.10.3.1 General
—
2.10.3.2
Mains transient voltages
—
a) AC mains supply ............................................... :
—
b) Earthed d.c. mains supplies ............................. :
N/A
c) Unearthed d.c. mains supplies ......................... :
N/A
d) Battery operation .............................................. :
N/A
2.10.3.3
Clearances in primary circuits
N/A
2.10.3.4
Clearances in secondary circuits
N/A
2.10.3.5
Clearances in circuits having starting pulses
N/A
2.10.3.6
Transients from a.c. mains supply ........................ :
N/A
2.10.3.7
Transients from d.c. mains supply ........................ :
N/A
2.10.3.8
Transients from telecommunication networks and
cable distribution systems ..................................... :
cable distribution systems ..................................... :
N/A
2.10.3.9
Measurement of transient voltage levels
—
a) Transients from a mains supply
N/A
For an a.c. mains supply ....................................... :
N/A
For a d.c. mains supply ......................................... :
N/A
b) Transients from a telecommunication network :
N/A
2.10.4 Creepage
distances
—
2.10.4.1 General
—
2.10.4.2
Material group and comparative tracking index
—
CTI
tests
.................................................................
:
2.10.4.3
Minimum creepage distances
N/A
2.10.5 Solid
insulation
—
2.10.5.1 General
—
2.10.5.2
Distances through insulation
N/A
2.10.5.3
Insulating compound as solid insulation
N/A
2.10.5.4 Semiconductor
devices
N/A
2.10.5.5 Cemented
joints
N/A
2.10.5.6
Thin sheet material – General
N/A
Click on the first or last page to see other PULSE (serv.man6) service manuals if exist.