Page 13 of 51 
Report No. 241619 
 
  
IEC 
60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
 
TRF No. IEC60950_1C 
 
 
1.5.9 
Surge suppressors 
No such component used 
N/A 
1.5.9.1 General 
 
N/A 
1.5.9.2 
Protection of VDRs 
 
N/A 
1.5.9.3 
Bridging of functional insulation by a VDR 
 
N/A 
1.5.9.4 
Bridging of basic insulation by a VDR 
 
N/A 
1.5.9.5 
Bridging of supplementary, double or reinforced 
insulation by a VDR 
 N/A 
 
1.6 Power 
interface 
1.6.1 
AC power distribution systems 
The equipment is regarded as 
Class III. 
N/A 
1.6.2 Input 
current 
(see appended table 1.6.2)  
1.6.3 
Voltage limit of hand-held equipment 
The equipment is not hand-
held. 
N/A 
1.6.4 
Neutral conductor  
The equipment is regarded as 
Class III. 
N/A 
 
1.7 
Marking and instructions 
1.7.1 
Power rating and identification markings 
The required marking is 
located on the outside surface 
of the equipment. 
1.7.1.1 
Power rating marking 
See below 
 
Multiple mains supply connections..........................: Class III equipment. 
N/A 
 
Rated voltage(s) or voltage range(s) (V)  .............. : 5V DC 
 
Symbol for nature of supply, for d.c. only .............. : IEC 60417-1, symbol No. 
5031, is used. 
 
Rated frequency or rated frequency range (Hz)  ... : DC supplied. 
N/A 
 
Rated current (mA or A)  ........................................ : 2.3A 
 
1.7.1.2 
Identification markings 
See below. 
 
Manufacturer’s name or trade-mark or identification 
mark  ...................................................................... :
See page 2 
 
Model identification or type reference  ................... : See page 2 
 
 
Symbol for Class II equipment only  ...................... : Class III equipment  
N/A 
 
Other markings and symbols  ................................ : The  additional marking does 
not give rise to 
misunderstandings. 
 
Page 14 of 51 
Report No. 241619 
 
  
IEC 
60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
 
TRF No. IEC60950_1C 
 
 
1.7.2 
Safety instructions and marking 
The user’s manual contains 
information for operation, 
installation, servicing, 
transport, storage, technical 
data and battery show in the 
user manual. No other special 
installation instruction 
required as the equipment is 
class III. 
1.7.2.1 General 
Considered. 
 
1.7.2.2 
Disconnect devices 
Class III equipment. 
N/A 
1.7.2.3 Overcurrent 
protective device 
Class III equipment. 
N/A 
1.7.2.4 
IT power distribution systems 
Class III equipment. 
N/A 
1.7.2.5 
Operator access with a tool 
All areas containing hazard(s) 
are inaccessible to the 
operator. 
1.7.2.6 
Ozone 
The equipment does not 
produce Ozone. 
N/A 
1.7.3 
Short duty cycles 
The equipment is intended for 
continuous operation. 
N/A 
1.7.4 
Supply voltage adjustment  ................................... :  No voltage select switch. 
N/A 
 
Methods and means of adjustment; reference to 
installation instructions  ......................................... : 
 
 
1.7.5 
Power outlets on the equipment  .......................... :  No standard power outlet. 
N/A 
1.7.6 
Fuse identification (marking, special fusing 
characteristics, cross-reference)  .......................... : 
Class III equipment. 
N/A 
1.7.7 
Wiring terminals 
Class III equipment. 
 
1.7.7.1 Protective 
earthing 
and bonding terminals  .......... :   
N/A 
1.7.7.2 
Terminals for a.c. mains supply conductors  
 
N/A 
1.7.7.3 
Terminals for d.c. mains supply conductors 
 
N/A 
1.7.8 
Controls and indicators 
Refer below. 
 
1.7.8.1 
Identification, location and marking  ..................... :  The function of controls 
affecting safety is obvious 
without knowledge of 
language etc. 
1.7.8.2 Colours 
  ................................................................ :   
N/A 
1.7.8.3 
Symbols according to IEC 60417 ........................ : 
The functional switch is 
marked with the symbols:       
 " (IEC 60417-1 No. 
5010). 
 
Page 15 of 51 
Report No. 241619 
 
  
IEC 
60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
 
TRF No. IEC60950_1C 
 
 
1.7.8.4 
Markings using figures   ....................................... : 
No controls. 
N/A 
1.7.9 
Isolation of multiple power sources  ..................... : 
Class III equipment. N/A 
1.7.10 
Thermostats and other regulating devices .......... : 
No thermostats or other 
regulating devices. 
N/A 
1.7.11 
Durability 
The marking withstands 
required tests. 
1.7.12 
Removable parts 
No removable part. 
N/A 
1.7.13 Replaceable 
batteries  ......................................... : 
The Li-ion battery pack is not 
user replaceable. 
N/A 
 Language(s) 
 ........................................................ : 
English 
— 
1.7.14 
Equipment for restricted access locations ........... : 
Equipment not intended for 
installation in RAL. 
N/A 
 
PROTECTION FROM HAZARDS 
2.1 
Protection from electric shock and energy hazards 
 
2.1.1 
Protection in operator access areas  
Refer below: 
 
2.1.1.1 
Access to energized parts 
Energized parts are not 
accessible. 
N/A 
 
Test by inspection  ................................................. :  
N/A 
 
Test with test finger (Figure 2A)  ............................ :  
N/A 
 
Test with test pin (Figure 2B)  ................................ :  
N/A 
 
Test with test probe (Figure 2C)  ........................... : No TNV circuit in the 
equipment. 
N/A 
2.1.1.2 
Battery compartments  
No TNV circuits in the 
equipment. 
N/A 
2.1.1.3 
Access to ELV wiring 
The equipment is regarded as 
class III. 
N/A 
 
Working voltage (Vpeak or Vrms); minimum 
distance through insulation (mm) 
 
 
2.1.1.4 
Access to hazardous voltage circuit wiring 
The equipment is regarded as 
class III. 
N/A 
2.1.1.5 Energy 
hazards  ................................................. : 
No energy hazard in operator 
access area. Checked by 
means of the test finger.
 
2.1.1.6 Manual 
controls 
No 
shafts of knobs etc. 
N/A 
2.1.1.7 
Discharge of capacitors in equipment 
The equipment is regarded as 
class III. 
N/A 
 
Measured voltage (V); time-constant (s) ............ : 
 
 
 
Page 16 of 51 
Report No. 241619 
 
  
IEC 
60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
 
TRF No. IEC60950_1C 
 
 
2.1.1.8 
Energy hazards – d.c. mains supply 
Not connected to DC mains 
supply. 
N/A 
 
a) Capacitor connected to the d.c. mains supply  .. :  
N/A 
 
 N/A 
2.1.1.9 Audio 
amplifiers ................................................. : 
The accessible audio terminal
complies with 2.1.1.1. 
2.1.2 
Protection in service access areas 
Checked by inspection 
unintentional contact is 
unlikely during service 
operations. 
2.1.3 
Protection in restricted access locations 
Equipment not intended for 
installation in RAL. 
N/A 
 
 
 
 
2.2 SELV 
circuits 
N/A 
2.2.1 
General requirements 
Class III equipment. 
N/A 
2.2.2 
Voltages under normal conditions (V)  ................... :  
N/A 
2.2.3 
Voltages under fault conditions (V)  ....................... :  
N/A 
2.2.4 
Connection of SELV circuits to other circuits  ...... : 
 
N/A 
 
 
 
 
2.3 TNV 
circuits 
N/A 
2.3.1 
Limits 
No TNV circuits. 
N/A 
 
Type of TNV circuits ............................................... :  
 
2.3.2 
Separation from other circuits and from accessible 
parts 
 
N/A 
2.3.2.1 General 
requirements 
 
N/A 
2.3.2.2 
Protection by basic insulation 
 
N/A 
2.3.2.3 
Protection by earthing 
 
N/A 
2.3.2.4 
Protection by other constructions  ......................... :  
N/A 
2.3.3 
Separation from hazardous voltages 
 
N/A 
 Insulation 
employed ............................................... :  
 
2.3.4 
Connection of TNV circuits to other circuits 
 
N/A 
 Insulation 
employed ............................................... :  
 
2.3.5 
Test for operating voltages generated externally 
 
N/A 
 
 
 
 
2.4 
Limited current circuits 
N/A 
Page of 118