JBL PULSE (serv.man6) EMC - CB Certificate ▷ View online
Page 25 of 51
Report No. 241619
IEC
60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1C
4.2.4
Steady force test, 250 N
No hazard. The test is
performed at External
enclosure.
performed at External
enclosure.
P
4.2.5
Impact test
Impact test not applicable.
N/A
Fall
test
N/A
Swing
test
N/A
4.2.6
Drop test; height (mm) .......................................... : No hazard as result from the
drop test at 1000mm height.
P
4.2.7
Stress relief test
Test is carried out at 70°C /
7hrs. No risk of shrinkage or
distortion on enclosures due
to release of internal stresses.
7hrs. No risk of shrinkage or
distortion on enclosures due
to release of internal stresses.
P
4.2.8
Cathode ray tubes
CRT(s) not used in the
equipment.
equipment.
N/A
Picture tube separately certified ............................ :
N/A
4.2.9
High pressure lamps
No high pressure lamps in the
equipment.
equipment.
N/A
4.2.10
Wall or ceiling mounted equipment; force (N) ....... : Not intended to be mounted
on a wall or ceiling.
N/A
4.3
Design and construction
P
4.3.1
Edges and corners
All edges and corners are
rounded and/or smoothed.
rounded and/or smoothed.
P
4.3.2
Handles and manual controls; force (N) ............. :
No knobs, grips, handles,
lever etc.
lever etc.
N/A
4.3.3
Adjustable controls
No hazardous adjustable
controls.
controls.
N/A
4.3.4
Securing of parts
No loosening of parts
impairing creepage distances
or clearances is likely to
occur.
impairing creepage distances
or clearances is likely to
occur.
P
4.3.5
Connection by plugs and sockets
SELV connectors do not
comply with IEC 60320 or IEC
60083.
comply with IEC 60320 or IEC
60083.
P
4.3.6
Direct plug-in equipment
Not direct plug-in equipment.
N/A
Torque
.................................................................. :
Compliance with the relevant mains plug standard
.............................................................................. :
.............................................................................. :
N/A
4.3.7
Heating elements in earthed equipment
No heating elements
provided.
provided.
N/A
Page 26 of 51
Report No. 241619
IEC
60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1C
4.3.8
Batteries
Refer to below:
P
- Overcharging of a rechargeable battery
(see appended table 4.3.8).
P
- Unintentional charging of a non-rechargeable
battery
battery
No such battery.
N/A
- Reverse charging of a rechargeable battery
There is no reverse polarity
installation could be happen
due to design of socket and
mechanical construction.
installation could be happen
due to design of socket and
mechanical construction.
N/A
- Excessive discharging rate for any battery
(see appended table 4.3.8)
P
4.3.9
Oil and grease
Insulation is not exposed to
oil, grease etc.
oil, grease etc.
N/A
4.3.10
Dust, powders, liquids and gases
The equipment does not
produce dust or using
powder, liquids or gases.
produce dust or using
powder, liquids or gases.
N/A
4.3.11
Containers for liquids or gases
No containers for liquids or
gases in the equipment.
gases in the equipment.
N/A
4.3.12 Flammable
liquids
................................................ :
The equipment does not
contain flammable liquid.
contain flammable liquid.
N/A
Quantity of liquid (l) .............................................. :
N/A
Flash point (
C) .................................................... :
N/A
4.3.13 Radiation
Refer
below:
—
4.3.13.1 General
Refer
below:
—
4.3.13.2 Ionizing
radiation
The equipment does not
generate ionizing radiation.
generate ionizing radiation.
N/A
Measured radiation (pA/kg) .................................. :
Measured
high-voltage (kV) ................................. :
Measured focus voltage (kV) ............................... :
CRT
markings ...................................................... :
4.3.13.3
Effect of ultraviolet (UV) radiation on materials
The equipment does not
produce significant UV
radiation.
produce significant UV
radiation.
N/A
Part, property, retention after test, flammability
classification ......................................................... :
classification ......................................................... :
N/A
4.3.13.4
Human exposure to ultraviolet (UV) radiation ...... :
The equipment does not
produce significant UV
radiation.
produce significant UV
radiation.
N/A
4.3.13.5
Lasers (including laser diodes) and LEDs
See below
—
4.3.13.5.1 Lasers (including laser diodes)
No lasers
N/A
Page 27 of 51
Report No. 241619
IEC
60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1C
Laser class ........................................................... :
4.3.13.5.2 Light emitting diodes (LEDs)
LED is of diffusive type.
P
4.3.13.6
Other types ........................................................... :
The equipment does not
generate other types of
radiation.
radiation.
N/A
4.4
Protection against hazardous moving parts
N/A
4.4.1
General
No moving parts.
N/A
4.4.2
Protection in operator access areas .................... :
No moving parts.
N/A
Household and home/office document/media
shredders
shredders
N/A
4.4.3
Protection in restricted access locations .............. :
Not intended for installation in
RAL.
RAL.
N/A
4.4.4
Protection in service access areas
Unintentional contact is not
likely in service accoss areas.
likely in service accoss areas.
N/A
4.4.5
Protection against moving fan blades
No such parts
N/A
4.4.5.1 General
N/A
Not considered to cause pain or injury. a)……….:
N/A
Is considered to cause pain, not injury. b)…………:
N/A
Considered to cause injury. c) …………:
N/A
4.4.5.2
Protection for users
N/A
Use of symbol or warning …………………………:
N/A
4.4.5.3
Protection for service persons
N/A
Use of symbol or warning …………………………:
N/A
4.5 Thermal
requirements
P
4.5.1 General
See
below.
P
4.5.2
Temperature tests
(see appended table 4.5)
—
Normal load condition per Annex L
................. :
P
4.5.3
Temperature limits for materials
(see appended table 4.5)
—
4.5.4
Touch temperature limits
(see appended table 4.5)
P
4.5.5 Resistance
to
abnormal heat ............................... :
N/A
4.6
Openings in enclosures
P
4.6.1
Top and side openings
Transportable equipment.
N/A
Page 28 of 51
Report No. 241619
IEC
60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1C
Dimensions
(mm) ................................................. :
—
4.6.2
Bottoms of fire enclosures
Transportable equipment.
N/A
Construction of the bottom, dimensions (mm) ..... :
—
4.6.3
Doors or covers in fire enclosures
No doors or covers in fire
enclosure.
enclosure.
N/A
4.6.4
Openings in transportable equipment
Refer to below:
P
4.6.4.1 Constructional
design measures
Considered.
P
Dimensions
(mm) ................................................. :
Metal Mesh(with 0.5mm
thickness):
Numerous square
openning 1.5mm x 1.5mm,
Spacing between centre
lines: 2.0mm
thickness):
Numerous square
openning 1.5mm x 1.5mm,
Spacing between centre
lines: 2.0mm
—
4.6.4.2
Evaluation measures for larger openings
N/A
4.6.4.3
Use of metallized parts
N/A
4.6.5
Adhesives for constructional purposes
N/A
Conditioning temperature (
C), time (weeks) ....... :
4.7
Resistance to fire
P
4.7.1
Reducing the risk of ignition and spread of flame
Method 1 and Method 2 are
used.
used.
P
Method 1, selection and application of components
wiring and materials
wiring and materials
(see appended table 1.5.1)
P
Method 2, application of all of simulated fault
condition tests
condition tests
(see appended table 5.3)
P
4.7.2
Conditions for a fire enclosure
Refer below.
4.7.2.1
Parts requiring a fire enclosure
The fire enclosure is required
to cover all parts except parts
evaluated with fault condition
tests.
to cover all parts except parts
evaluated with fault condition
tests.
P
4.7.2.2
Parts not requiring a fire enclosure
See clause 4.7.1,
P
4.7.3 Materials
P
4.7.3.1
General
Components and materials
have adequate flammability
classification. See appended
table 1.5.1.
have adequate flammability
classification. See appended
table 1.5.1.
P
4.7.3.2
Materials for fire enclosures
The fire enclosure is
constructed metal(mesh)and
V-0 plastic material.
constructed metal(mesh)and
V-0 plastic material.
P
Click on the first or last page to see other PULSE (serv.man6) service manuals if exist.