JBL ON TOUR XTB (serv.man8) EMC - CB Certificate ▷ View online

 
 
- Page 21 of 57 - 
 
 
www.nemko.com
 
Report No.  111547 
 
 
TRF No.:IECEN60950_1B 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict
3.1.5 Beads 
and 
ceramic 
insulators 
No beads or similar ceramic 
insulators on conductors. 
N/A
 
3.1.6 
Screws for electrical contact pressure 
No screws used for electrical 
contact. 
N/A
 
3.1.7 
Insulating materials in electrical connections 
No contact pressure through 
insulating material. 
N/A
 
3.1.8 
Self-tapping and spaced thread screws 
 
N/A
 
3.1.9 Termination 
of 
conductors 
Class III equipment powered by 
an external Limited Power 
Source. 
N/A
 
 
10 N pull test 
 
N/A
 
3.1.10 Sleeving 
on 
wiring 
No sleeving provided. 
N/A
 
 
3.2 
Connection to an a.c. mains supply or a d.c. mains supply  
N/A
 
3.2.1 Means 
of 
connection 
.......................................... : 
Class III equipment. Unit is not 
intended for direct connection to 
a mains supply. Refer also to 
Summary of testing. 
 
N/A
 
3.2.1.1 
Connection to an a.c. mains supply 
 
N/A
 
3.2.1.2 
Connection to a d.c. mains supply 
 
N/A
 
3.2.2 
Multiple supply connections  
 
N/A
 
3.2.3 Permanently 
connected 
equipment 
 
N/A
 
 
Number of conductors, diameter (mm) of cable 
and conduits ....................................................... : 
 
— 
3.2.4 Appliance 
inlets 
 
N/A
 
3.2.5 
Power supply cords  
 
N/A
 
3.2.5.1 
AC power supply cords 
 
N/A
 
 Type .................................................................... : 
 
— 
 
Rated current (A), cross-sectional area (mm
2
),  
AWG....................................................................: 
 
— 
3.2.5.2 
DC power supply cords 
 
N/A
 
3.2.6 
Cord anchorages and strain relief 
 
N/A
 
 
Mass of equipment (kg), pull (N)  .......................: 
 
— 
 Longitudinal 
displacement 
(mm) 
........................: 
 
— 
3.2.7 
Protection against mechanical damage 
 
N/A
 
3.2.8 Cord 
guards 
 
N/A
 
 
D (mm); test mass (g)  ........................................: 
 
— 
 
 
- Page 22 of 57 - 
 
 
www.nemko.com
 
Report No.  111547 
 
 
TRF No.:IECEN60950_1B 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict
 
Radius of curvature of cord (mm) .......................: 
 
— 
3.2.9 Supply 
wiring 
space 
 
N/A
 
 
3.3 
Wiring terminals for connection of external conductors 
N/A
 
3.3.1 Wiring 
terminals 
Class III equipment. Unit is not 
intended for direct connection to 
a mains supply. See attached 
PSU report. 
N/A
 
3.3.2 
Connection of non-detachable power supply 
cords 
 
N/A
 
3.3.3 Screw 
terminals 
 
N/A
 
3.3.4 
Conductor sizes to be connected 
 
N/A
 
 
Rated current (A), cord/cable type, cross-
sectional area (mm
2
)........................................... : 
 
— 
3.3.5 Wiring 
terminal 
sizes 
 
N/A
 
 
Rated current (A), type and nominal thread 
diameter (mm) .................................................... : 
 
— 
3.3.6 Wiring 
terminal 
design 
 
N/A
 
3.3.7 
Grouping of wiring terminals 
 
N/A
 
3.3.8 Stranded 
wire 
 
N/A
 
 
3.4 
Disconnection from the mains supply 
N/A
 
3.4.1 General 
requirement 
Class III equipment. Unit is not 
intended for direct connection to 
a mains supply. 
 
N/A
 
3.4.2 Disconnect 
devices 
 
N/A
 
3.4.3 Permanently 
connected 
equipment 
 
N/A
 
3.4.4 
Parts which remain energized 
 
N/A
 
3.4.5 Switches 
in 
flexible cords 
 
N/A
 
3.4.6 
Single-phase equipment and d.c. equipment 
 
N/A
 
3.4.7 Three-phase 
equipment 
 
N/A
 
3.4.8 
Switches as disconnect devices 
 
N/A
 
3.4.9 
Plugs as disconnect devices 
 
N/A
 
3.4.10 Interconnected 
equipment 
 
N/A
 
3.4.11 Multiple 
power 
sources 
 
N/A
 
 
 
 
- Page 23 of 57 - 
 
 
www.nemko.com
 
Report No.  111547 
 
 
TRF No.:IECEN60950_1B 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict
3.5 
Interconnection of equipment 
N/A
 
3.5.1 General 
requirements 
 
N/A
 
3.5.2 
Types of interconnection circuits ......................... :
SELV circuits only. 
N/A
 
3.5.3 
ELV circuits as interconnection circuits  
No ELV interconnections. 
N/A
 
 
4 PHYSICAL 
REQUIREMENTS 
P
 
4.1 Stability 
P
 
 
Angle of 10
° 
Unit does not overbalance at 
10°. 
P
 
 Test: 
force 
(N) ...................................................... :
The unit is not floor-standing. 
N/A
 
4.2 Mechanical 
strength 
N/A
 
4.2.1 General 
Class III equipment for supply 
from LPS source. Only functional 
insulation provided. No shock or 
energy hazard, no test 
considered necessary.  
N/A
 
4.2.2 
Steady force test, 10 N 
 
N/A
 
4.2.3 
Steady force test, 30 N 
 
N/A
 
4.2.4 
Steady force test, 250 N 
 
N/A
 
4.2.5 Impact 
test 
 
N/A
 
 Fall 
test 
 
N/A
 
 Swing 
test 
 
N/A
 
4.2.6 Drop 
test 
 
N/A
 
4.2.7 
Stress relief test 
No shock or energy hazard, no 
test considered necessary.
 
N/A
 
4.2.8 Cathode 
ray 
tubes 
CRT(s) not used in the 
equipment. 
N/A
 
 
Picture tube separately certified .........................: 
 
N/A
 
4.2.9 High 
pressure 
lamps 
No high-pressure lamps in the 
equipment. 
N/A
 
4.2.10 Wall 
or 
ceiling mounted equipment; force (N)  ...: 
Not intended to be mounted on a 
wall or ceiling. 
N/A
 
 
4.3 
Design and construction  
P
 
4.3.1 
Edges and corners 
All edges and corners are 
rounded and/or smoothed.
 
P
 
 
 
- Page 24 of 57 - 
 
 
www.nemko.com
 
Report No.  111547 
 
 
TRF No.:IECEN60950_1B 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict
4.3.2 
Handles and manual controls; force (N) .............: 
No knobs, grips, handles, lever 
etc.
 
N/A
 
4.3.3 
Adjustable controls  
No hazardous adjustable 
controls.
 
N/A
 
4.3.4 
Securing of parts 
No loosening of parts is likely to 
occur.
 
P
 
4.3.5 
Connection of plugs and sockets 
SELV connectors do not comply 
with IEC 60320 or IEC 60083.
 
P
 
4.3.6 Direct 
plug-in 
equipment 
Not intended to plug directly into 
a wall socket-outlet.
 
N/A
 
 
Dimensions (mm) of mains plug for direct plug-in   
............................................................................ : 
 
N/A
 
 
Torque and pull test of mains plug for direct 
plug-in; torque (Nm); pull (N) .............................. : 
 
N/A
 
4.3.7 
Heating elements in earthed equipment 
No heating elements provided.
 
N/A
 
4.3.8 Batteries 
Refer to summary of testing and 
appended table 4.3.8. 
P
 
4.3.9 
Oil and grease 
Insulation is not exposed to oil, 
grease etc.
 
N/A
 
4.3.10 
Dust, powders, liquids and gases 
The equipment does not 
generate dust, powders, liquids 
and gases, and does not contain 
flammable liquids or gases. 
N/A
 
4.3.11 
Containers for liquids or gases 
No containers for liquids or 
gases in the equipment.
 
N/A
 
4.3.12 Flammable 
liquids ...............................................: 
The equipment does not contain 
flammable liquid.
 
N/A
 
 
Quantity of liquid (l) .............................................: 
 
N/A
 
 
Flash point (
°C) ...................................................: 
 
N/A
 
4.3.13 
Radiation; type of radiation  ................................: 
The equipment does not 
generate radiation. 
N/A
 
4.3.13.1 General 
 
N/A
 
4.3.13.2 Ionizing 
radiation 
 
 
N/A
 
 Measured 
radiation 
(pA/kg) 
................................ :
 
— 
 Measured 
high-voltage 
(kV) 
................................ :
 
— 
 
Measured focus voltage (kV)  .............................. :
 
— 
 CRT 
markings 
..................................................... :
 
— 
4.3.13.3 
Effect of ultraviolet (UV) radiation on materials 
 
N/A
 