JBL ON TOUR XTB (serv.man8) EMC - CB Certificate ▷ View online
- Page 33 of 57 -
www.nemko.com
Report No. 111547
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
M.3.2.2 Tripping
device
N/A
M.3.2.3 Monitoring
voltage
(V)......................................... :
N/A
N
ANNEX N, IMPULSE TEST GENERATORS (see 2.10.3.4, 6.2.2.1, 7.3.2 and
clause G.5)
clause G.5)
N/A
N.1 ITU-T
impulse
test
generators
N/A
N.2
IEC 60065 impulse test generator
N/A
P
ANNEX P, NORMATIVE REFERENCES
N/A
Q ANNEX
Q,
BIBLIOGRAPHY
N/A
R
ANNEX R, EXAMPLES OF REQUIREMENTS FOR QUALITY CONTROL
PROGRAMMES
PROGRAMMES
N/A
R.1
Minimum separation distances for unpopulated
coated printed boards (see 2.10.6)
coated printed boards (see 2.10.6)
N/A
R.2
Reduced clearances (see 2.10.3)
N/A
S
ANNEX S, PROCEDURE FOR IMPULSE TESTING (see 6.2.2.3)
N/A
S.1 Test
equipment
N/A
S.2 Test
procedure
N/A
S.3
Examples of waveforms during impulse testing
N/A
T
ANNEX T, GUIDANCE ON PROTECTION AGAINST INGRESS OF WATER
(see 1.1.2)
(see 1.1.2)
N/A
—
U
ANNEX U, INSULATED WINDING WIRES FOR USE WITHOUT INTERLEAVED
INSULATION (see 2.10.5.4)
INSULATION (see 2.10.5.4)
N/A
—
V
ANNEX V, AC POWER DISTRIBUTION SYSTEMS (see 1.6.1)
N/A
V.1 Introduction
N/A
V.2
TN power distribution systems
N/A
- Page 34 of 57 -
www.nemko.com
Report No. 111547
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
W
ANNEX W, SUMMATION OF TOUCH CURRENTS
N/A
W.1
Touch current from electronic circuits
N/A
W.1.1 Floating
circuits
N/A
W.1.2 Earthed
circuits
N/A
W.2
Interconnection of several equipments
N/A
W.2.1 Isolation
N/A
W.2.2
Common return, isolated from earth
N/A
W.2.3
Common return, connected to protective earth
N/A
X
ANNEX X, MAXIMUM HEATING EFFECT IN TRANSFORMER TESTS (see clause
C.1)
C.1)
N/A
X.1
Determination of maximum input current
N/A
X.2
Overload test procedure
N/A
Y
ANNEX Y, ULTRAVIOLET LIGHT CONDITIONING TEST (see 4.3.13.3)
N/A
Y.1 Test
apparatus
................................................... :
N/A
Y.2
Mounting of test samples ................................... :
N/A
Y.3 Carbon-arc
light-exposure
apparatus
................ :
N/A
Y.4 Xenon-arc
light
exposure
apparatus
.................. :
N/A
- Page 35 of 57 -
www.nemko.com
Report No. 111547
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
CENELEC COMMON MODIFICATIONS [C], SPECIAL NATIONAL CONDITIONS [S] AND
A-DEVIATIONS (NATIONAL DEVIATIONS) [A] (EN 60950-1:2001 + A11:2004)
A-DEVIATIONS (NATIONAL DEVIATIONS) [A] (EN 60950-1:2001 + A11:2004)
P
General
C: Delete all the "country" notes in the reference
document according to the following list:
document according to the following list:
1.1.5
Note 2
1.5.8
Note 2
1.6.1 Note
1.7.2 Note
4 1.7.12 Note
2 2.1 Note
2.2.3
Note
2.2.4
Note
2.3.2 Note 2, 7, 8
2.3.3
Note 1, 2 2.3.4
Note 2,3 2.7.1 Note
2.10.3.1 Note 4
3.2.1.1 Note
3.2.3 Note 1, 2
3.2.5.1 Note
2
4.3.6
Note
1,2 4.7.2.2 Note
4.7.3.1 Note
2
6.1.2.1 Note
6.1.2.2 Note
6.2.2 Note
6.2.2.1 Note
2 6.2.2.2
Note
7 Note
4
7.1 Note
G2.1
Note 1, 2 Annex H Note 2
N/A
1.2.4.1
S (DK): Certain types of Class I appliances (see
3.2.1.1) may be provided with a plug not
establishing earthing conditions when inserted
into Danish socket-outlets.
3.2.1.1) may be provided with a plug not
establishing earthing conditions when inserted
into Danish socket-outlets.
Class III equipment. Unit is not
intended for direct connection
to a mains supply.
intended for direct connection
to a mains supply.
N/A
1.5.1
A (SE, Ordinance 1990:944) and
(CH, Ordinance on environmentally hazardous
substances SR 814.013, Annex 3.2, Mercury):
Add the following:
(CH, Ordinance on environmentally hazardous
substances SR 814.013, Annex 3.2, Mercury):
Add the following:
NOTE – Switches containing mercury such as thermostats,
relays and level controllers are not allowed.
relays and level controllers are not allowed.
There are no components
containing mercury in the
equipment.
containing mercury in the
equipment.
N/A
1.5.8
S (NO): Due to the IT power system used (see
annex V, Fig. V.7), capacitors are required to be
rated for the applicable line-to-line voltage
(230 V).
annex V, Fig. V.7), capacitors are required to be
rated for the applicable line-to-line voltage
(230 V).
Class III equipment. Unit is not
intended for direct connection
to a mains supply.
intended for direct connection
to a mains supply.
N/A
1.7.2
S (FI, NO, SE): C
LASS
I
PLUGGABLE EQUIPMENT
TYPE
A intended for connection to other
equipment or a network shall, if safety relies on
connection to protective earth or if surge
suppressors are connected between the network
terminals and accessible parts, have a marking
stating that the equipment must be connected to
an earthed mains socket-outlet.
The marking text in the applicable countries shall
be as follows:
connection to protective earth or if surge
suppressors are connected between the network
terminals and accessible parts, have a marking
stating that the equipment must be connected to
an earthed mains socket-outlet.
The marking text in the applicable countries shall
be as follows:
Class III equipment. Unit is not
intended for direct connection
to a mains supply.
intended for direct connection
to a mains supply.
N/A
FI: "Laite on liitettävä suojamaadoitus-
koskettimilla varustettuun pistorasiaan"
koskettimilla varustettuun pistorasiaan"
Class III equipment.
N/A
NO: "Apparatet må tilkoples jordet stikkontakt"
Class III equipment.
N/A
SE: "Apparaten skall anslutas till jordat uttag"
Class III equipment.
N/A
A (DK, Heavy Current Regulations): Supply cords
of
of
CLASS
I
EQUIPMENT
, which is delivered without
a plug, must be provided with a visible tag with
the following text:
the following text:
Class III equipment. Unit is not
intended for direct connection
to a mains supply.
intended for direct connection
to a mains supply.
N/A
- Page 36 of 57 -
www.nemko.com
Report No. 111547
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
Vigtigt!
Lederen med grøn/gul isolation må kun tilsluttes
en klemme mærket
Lederen med grøn/gul isolation må kun tilsluttes
en klemme mærket
eller
If essential for the safety of the equipment, the
tag must in addition be provided with a diagram
which shows the connection of the other
conductors, or be provided with the following text:
"For tilslutning af de øvrige ledere, se
medfølgende installationsvejledning."
tag must in addition be provided with a diagram
which shows the connection of the other
conductors, or be provided with the following text:
"For tilslutning af de øvrige ledere, se
medfølgende installationsvejledning."
1.7.5
S (DK): Socket-outlets for providing power to
other equipment shall be in accordance with the
Heavy Current Regulations, Section 107-2-D1,
Standard Sheet DK 1-3a, DK 1-5a or DK 1-7a,
when used on Class I equipment. For
other equipment shall be in accordance with the
Heavy Current Regulations, Section 107-2-D1,
Standard Sheet DK 1-3a, DK 1-5a or DK 1-7a,
when used on Class I equipment. For
STATIONARY
EQUIPMENT
the socket-outlet shall be
in accordance with Standard Sheet DK 1-1b or
DK 1-5a.
DK 1-5a.
No such sockets.
N/A
1.7.5
A (DK, Heavy Current Regulations):
CLASS
II
EQUIPMENT
shall not be fitted with socket-
outlets for providing power to other equipment.
No socket outlets.
N/A
1.7.12
A (DE, Gesetz über technische Arbeitsmittel
(Gerätesicherheitsgesetz) [Law on technical
labour equipment {Equipment safety law}], of 23
(Gerätesicherheitsgesetz) [Law on technical
labour equipment {Equipment safety law}], of 23
rd
October 1992, Article 3, 3
rd
paragraph, 2
nd
sentence, together with the "Allgemeine
Verwaltungsvorschrift zur Durchführung des
Zweiten Abschnitts des Gerätesicherheits-
gesetzes" [General administrative regulation on
the execution of the Second Section of the
Equipment safety law], of 10
Verwaltungsvorschrift zur Durchführung des
Zweiten Abschnitts des Gerätesicherheits-
gesetzes" [General administrative regulation on
the execution of the Second Section of the
Equipment safety law], of 10
th
January 1996,
article 2, 4
th
paragraph item 2).
Directions for use with rules to prevent certain
hazards for (among others) maintenance of the
technical labour equipment, also for imported
technical labour equipment shall be written in the
German language.
hazards for (among others) maintenance of the
technical labour equipment, also for imported
technical labour equipment shall be written in the
German language.
NOTE: Of this requirement, rules for use even only by service
personnel are not exempted.
personnel are not exempted.
Must be considered before
marketed in Germany.
marketed in Germany.
N/A
1.7.15
A (CH, Ordinance on environmentally hazardous
substances SR 814.013):
Annex 4.10 of SR 814.013 applies for batteries.
substances SR 814.013):
Annex 4.10 of SR 814.013 applies for batteries.
There is no battery containing
Cd or Hg in the equipment.
Cd or Hg in the equipment.
N/A
2.2.4
S (NO): Requirements according to this annex,
1.7.2 and 6.1.2.1 apply.
1.7.2 and 6.1.2.1 apply.
No TNV circuits.
N/A
2.3.2
S (NO): Requirements according to this annex,
6.1.2.1 apply.
6.1.2.1 apply.
No TNV circuits.
N/A
Click on the first or last page to see other ON TOUR XTB (serv.man8) service manuals if exist.