DOWNLOAD JBL ON TOUR XTB (serv.man8) Service Manual ↓ Size: 765 KB | Pages: 86 in PDF or view online for FREE

Model
ON TOUR XTB (serv.man8)
Pages
86
Size
765 KB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
on-tour-xtb-sm8.pdf
Date

JBL ON TOUR XTB (serv.man8) EMC - CB Certificate ▷ View online

 
 
- Page 33 of 57 - 
 
 
www.nemko.com
 
Report No.  111547 
 
 
TRF No.:IECEN60950_1B 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict
M.3.2.2 Tripping 
device 
 
N/A
 
M.3.2.3 Monitoring 
voltage 
(V)......................................... : 
 
N/A
 
 
ANNEX N, IMPULSE TEST GENERATORS (see 2.10.3.4, 6.2.2.1, 7.3.2 and 
clause G.5) 
N/A
 
N.1 ITU-T 
impulse 
test 
generators 
 
N/A
 
N.2 
IEC 60065 impulse test generator 
 
N/A
 
 
ANNEX P, NORMATIVE REFERENCES 
N/A
 
 
Q ANNEX 
Q, 
BIBLIOGRAPHY 
N/A
 
 
ANNEX R, EXAMPLES OF REQUIREMENTS FOR QUALITY CONTROL 
PROGRAMMES 
N/A
 
R.1 
Minimum separation distances for unpopulated 
coated printed boards (see 2.10.6) 
 
N/A
 
R.2 
Reduced clearances (see 2.10.3) 
 
N/A
 
 
ANNEX S, PROCEDURE FOR IMPULSE TESTING (see 6.2.2.3) 
N/A
 
S.1 Test 
equipment 
 
N/A
 
S.2 Test 
procedure 
 
N/A
 
S.3 
Examples of waveforms during impulse testing 
 
N/A
 
 
ANNEX T, GUIDANCE ON PROTECTION AGAINST INGRESS OF WATER 
(see 1.1.2) 
N/A
 
 
 
 
— 
 
ANNEX U, INSULATED WINDING WIRES FOR USE WITHOUT INTERLEAVED 
INSULATION (see 2.10.5.4) 
N/A
 
 
 
 
— 
 
ANNEX V, AC POWER DISTRIBUTION SYSTEMS (see 1.6.1)  
N/A
 
V.1 Introduction 
 
N/A
 
V.2 
TN power distribution systems  
 
N/A
 
 
 
 
- Page 34 of 57 - 
 
 
www.nemko.com
 
Report No.  111547 
 
 
TRF No.:IECEN60950_1B 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict
ANNEX W, SUMMATION OF TOUCH CURRENTS  
N/A
 
W.1 
Touch current from electronic circuits 
 
N/A
 
W.1.1 Floating 
circuits 
 
N/A
 
W.1.2 Earthed 
circuits 
 
N/A
 
W.2 
Interconnection of several equipments 
 
N/A
 
W.2.1 Isolation 
 
N/A
 
W.2.2 
Common return, isolated from earth 
 
N/A
 
W.2.3 
Common return, connected to protective earth 
 
N/A
 
 
ANNEX X, MAXIMUM HEATING EFFECT IN TRANSFORMER TESTS (see clause 
C.1) 
N/A
 
X.1 
Determination of maximum input current  
 
N/A
 
X.2 
Overload test procedure 
 
N/A
 
 
ANNEX Y, ULTRAVIOLET LIGHT CONDITIONING TEST (see 4.3.13.3) 
N/A
 
Y.1 Test 
apparatus 
................................................... : 
 
N/A
 
Y.2 
Mounting of test samples  ................................... : 
 
N/A
 
Y.3 Carbon-arc 
light-exposure 
apparatus 
................ : 
 
N/A
 
Y.4 Xenon-arc 
light 
exposure 
apparatus 
.................. : 
 
N/A
 
 
 
 
 
- Page 35 of 57 - 
 
 
www.nemko.com
 
Report No.  111547 
 
 
TRF No.:IECEN60950_1B 
 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
CENELEC COMMON MODIFICATIONS [C], SPECIAL NATIONAL CONDITIONS [S] AND 
A-DEVIATIONS (NATIONAL DEVIATIONS) [A] (EN 60950-1:2001 + A11:2004) 
P
 
General 
C: Delete all the "country" notes in the reference 
document according to the following list: 
1.1.5  
Note 2 
1.5.8 
Note 2 
1.6.1  Note  
1.7.2 Note 
4  1.7.12 Note 
2 2.1  Note 
2.2.3 
Note 
2.2.4 
Note 
2.3.2  Note 2, 7, 8
2.3.3 
Note 1, 2  2.3.4 
Note 2,3  2.7.1  Note 
2.10.3.1 Note 4 
3.2.1.1  Note 
3.2.3  Note 1, 2 
3.2.5.1 Note 
4.3.6 
Note 
1,2 4.7.2.2 Note 
4.7.3.1 Note 
6.1.2.1  Note 
6.1.2.2 Note 
6.2.2 Note 
6.2.2.1 Note 
2 6.2.2.2 
Note 
7 Note 
7.1 Note 
 
G2.1 
Note 1, 2  Annex H  Note 2 
 
N/A
 
1.2.4.1 
S (DK): Certain types of Class I appliances (see 
3.2.1.1) may be provided with a plug not 
establishing earthing conditions when inserted 
into Danish socket-outlets. 
Class III equipment. Unit is not 
intended for direct connection 
to a mains supply.
 
N/A
 
1.5.1 
A (SE, Ordinance 1990:944) and  
(CH, Ordinance on environmentally hazardous 
substances SR 814.013, Annex 3.2, Mercury): 
Add the following: 
NOTE – Switches containing mercury such as thermostats, 
relays and level controllers are not allowed.
 
There are no components 
containing mercury in the 
equipment.
 
N/A
 
1.5.8 
S (NO): Due to the IT power system used (see 
annex V, Fig. V.7), capacitors are required to be 
rated for the applicable line-to-line voltage 
(230 V). 
Class III equipment. Unit is not 
intended for direct connection 
to a mains supply.
 
N/A
 
1.7.2 
S (FI, NO, SE): C
LASS 
PLUGGABLE EQUIPMENT 
TYPE 
A intended for connection to other 
equipment or a network shall, if safety relies on 
connection to protective earth or if surge 
suppressors are connected between the network 
terminals and accessible parts, have a marking 
stating that the equipment must be connected to 
an earthed mains socket-outlet. 
The marking text in the applicable countries shall 
be as follows: 
Class III equipment. Unit is not 
intended for direct connection 
to a mains supply.
 
N/A
 
 
FI: "Laite on liitettävä suojamaadoitus-
koskettimilla varustettuun pistorasiaan" 
Class III equipment.
 
N/A
 
 
NO: "Apparatet må tilkoples jordet stikkontakt" 
Class III equipment.
 
N/A
 
 
SE: "Apparaten skall anslutas till jordat uttag" 
Class III equipment.
 
N/A
 
 
A (DK, Heavy Current Regulations): Supply cords 
of 
CLASS
 I 
EQUIPMENT
, which is delivered without 
a plug, must be provided with a visible tag with 
the following text: 
Class III equipment. Unit is not 
intended for direct connection 
to a mains supply.
 
N/A
 
 
 
- Page 36 of 57 - 
 
 
www.nemko.com
 
Report No.  111547 
 
 
TRF No.:IECEN60950_1B 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
Vigtigt! 
Lederen med grøn/gul isolation må kun tilsluttes 
en klemme mærket 
 
 eller  
  
If essential for the safety of the equipment, the 
tag must in addition be provided with a diagram 
which shows the connection of the other 
conductors, or be provided with the following text: 
"For tilslutning af de øvrige ledere, se 
medfølgende installationsvejledning." 
1.7.5 
S (DK): Socket-outlets for providing power to 
other equipment shall be in accordance with the 
Heavy Current Regulations, Section 107-2-D1, 
Standard Sheet DK 1-3a, DK 1-5a or DK 1-7a, 
when used on Class I equipment. For 
STATIONARY
 
EQUIPMENT
 the socket-outlet shall be 
in accordance with Standard Sheet DK 1-1b or 
DK 1-5a. 
No such sockets. 
 
N/A
 
1.7.5 
A (DK, Heavy Current Regulations): 
CLASS
 II 
EQUIPMENT
 shall not be fitted with socket-
outlets for providing power to other equipment. 
No socket outlets. 
 
N/A
 
1.7.12 
A (DE, Gesetz über technische Arbeitsmittel 
(Gerätesicherheitsgesetz) [Law on technical 
labour equipment {Equipment safety law}], of 23
rd
 
October 1992, Article 3, 3
rd
 paragraph, 2
nd
 
sentence, together with the "Allgemeine 
Verwaltungsvorschrift zur Durchführung des 
Zweiten Abschnitts des Gerätesicherheits-
gesetzes" [General administrative regulation on 
the execution of the Second Section of the 
Equipment safety law], of 10
th
 January 1996, 
article 2, 4
th
 paragraph item 2).  
Directions for use with rules to prevent certain 
hazards for (among others) maintenance of the 
technical labour equipment, also for imported 
technical labour equipment shall be written in the 
German language. 
NOTE: Of this requirement, rules for use even only by service 
personnel are not exempted.  
Must be considered before 
marketed in Germany.
 
N/A
 
1.7.15 
A (CH, Ordinance on environmentally hazardous 
substances SR 814.013): 
Annex 4.10 of SR 814.013 applies for batteries. 
There is no battery containing 
Cd or Hg in the equipment.
 
N/A
 
2.2.4 
S (NO): Requirements according to this annex, 
1.7.2 and 6.1.2.1 apply. 
No TNV circuits.
 
N/A
 
2.3.2 
S (NO): Requirements according to this annex, 
6.1.2.1 apply. 
No TNV circuits.
 
N/A
 
Page of 86
Display

Click on the first or last page to see other ON TOUR XTB (serv.man8) service manuals if exist.