- Page 25 of 57 -
www.nemko.com
Report No. 111547
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
Part, property, retention after test, flammability
classification ........................................................ :
classification ........................................................ :
N/A
4.3.13.4
Human exposure to ultraviolet (UV) radiation ..... :
N/A
4.3.13.5
Laser (including LEDs)
No laser components. LEDs are
diffuse type.
diffuse type.
N/A
Laser
class
.......................................................... :
—
4.3.13.6 Other
types
.......................................................... :
No other radiation.
N/A
4.4
Protection against hazardous moving parts
N/A
4.4.1 General
No moving parts.
N/A
4.4.2
Protection in operator access areas
N/A
4.4.3
Protection in restricted access locations
N/A
4.4.4
Protection in service access areas
N/A
4.5 Thermal
requirements
P
4.5.1 Maximum
temperatures
(See appended table 4.5)
P
Normal load condition per Annex L..................... :
Refer to Test items particulars.
P
4.5.2
Resistance to abnormal heat
Class III equipment.
N/A
4.6 Openings
in
enclosures
P
4.6.1
Top and side openings
No side’s openings. Openings
on top of the equipment are so
small (0.6mm) that it is unlikely
that objects will enter the
openings and create hazards by
contacting bare conductive parts.
Class III equipment for supply
from LPS source. No shock or
energy hazard.
on top of the equipment are so
small (0.6mm) that it is unlikely
that objects will enter the
openings and create hazards by
contacting bare conductive parts.
Class III equipment for supply
from LPS source. No shock or
energy hazard.
P
Dimensions
(mm)
............................................... :
—
4.6.2
Bottoms of fire enclosures
No bottoms openings.
P
Construction of the bottom.................................. :
—
4.6.3
Doors or covers in fire enclosures
N/A
4.6.4
Openings in transportable equipment
Equipment can be powered from
battery and moved; equipment
additionally evaluated as
transportable equipment.
battery and moved; equipment
additionally evaluated as
transportable equipment.
P
- Page 26 of 57 -
www.nemko.com
Report No. 111547
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
4.6.5
Adhesives for constructional purposes
No barrier secured by adhesive
inside enclosure.
inside enclosure.
N/A
Conditioning temperature (
°C)/time (weeks) ...... :
—
4.7
Resistance to fire
P
4.7.1
Reducing the risk of ignition and spread of flame
Method 1 used.
P
Method 1, selection and application of
components wiring and materials
components wiring and materials
(See appended table 1.5.1)
P
Method 2, application of all of simulated fault
condition tests
condition tests
Not used.
N/A
4.7.2
Conditions for a fire enclosure
Refer below:
P
4.7.2.1
Parts requiring a fire enclosure
Equipment is class III equipment,
powered from a LPS. Fire
enclosure is not considered
necessary.
powered from a LPS. Fire
enclosure is not considered
necessary.
N/A
4.7.2.2
Parts not requiring a fire enclosure
Equipment is class III powered
from a LPS. Additionally, all
components are mounted on
V-1 or better material.
from a LPS. Additionally, all
components are mounted on
V-1 or better material.
P
4.7.3 Materials
P
4.7.3.1 General
Components and materials have
adequate flammability
classification. Refer to appended
table 1.5.1.
adequate flammability
classification. Refer to appended
table 1.5.1.
P
4.7.3.2
Materials for fire enclosures
Fire enclosure not required.
Refer to 4.7.2
Refer to 4.7.2
N/A
4.7.3.3
Materials for components and other parts outside
fire enclosures
fire enclosures
Fire enclosure not required.
Enclosure is rated V-2 min.
Enclosure is rated V-2 min.
P
4.7.3.4
Materials for components and other parts inside
fire enclosures
fire enclosures
Fire enclosure not required.
Refer to 4.7.2
Refer to 4.7.2
N/A
4.7.3.5
Materials for air filter assemblies
No air filters in the equipment.
N/A
4.7.3.6
Materials used in high-voltage components
No parts exceeding 4kV.
N/A
5
ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS
N/A
5.1
Touch current and protective conductor current
N/A
5.1.1 General
Class III equipment.
N/A
5.1.2
Equipment under test (EUT)
N/A
5.1.3 Test
circuit
N/A
- Page 27 of 57 -
www.nemko.com
Report No. 111547
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
5.1.4
Application of measuring instrument
N/A
5.1.5 Test
procedure
N/A
5.1.6 Test
measurements
N/A
Test
voltage
(V)
..................................................:
—
Measured touch current (mA) ............................:
—
Max. allowed touch current (mA) .......................:
—
Measured protective conductor current (mA) ....:
—
Max. allowed protective conductor current (mA) :
—
5.1.7
Equipment with touch current exceeding
3.5 mA ..............................................................:
3.5 mA ..............................................................:
N/A
5.1.8
Touch currents to telecommunication networks
and cable distribution systems and from
telecommunication networks
and cable distribution systems and from
telecommunication networks
N/A
5.1.8.1
Limitation of the touch current to a
telecommunication network and a cable
distribution system
telecommunication network and a cable
distribution system
N/A
Test
voltage
(V)
..................................................:
—
Measured touch current (mA) ............................:
—
Max. allowed touch current (mA) .......................:
—
5.1.8.2
Summation of touch currents from
telecommunication networks ..............................:
telecommunication networks ..............................:
N/A
5.2 Electric
strength
N/A
5.2.1 General
Class III equipment. Functional
insulation only.
insulation only.
N/A
5.2.2
Test procedure
N/A
5.3
Abnormal operating and fault conditions
P
5.3.1
Protection against overload and abnormal
operation
operation
Refer to appended table 5.3.
P
5.3.2 Motors
No motors in the equipment.
N/A
5.3.3 Transformers
No transformers in the
equipment.
equipment.
N/A
5.3.4 Functional
insulation ........................................... :
Complies with method C.
Component mounted on V-1 or
better material.
Component mounted on V-1 or
better material.
P
- Page 28 of 57 -
www.nemko.com
Report No. 111547
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
5.3.5 Electromechanical
components
No electromechanical
components in secondary
circuits.
components in secondary
circuits.
N/A
5.3.6
Simulation of faults
Refer to appended table 5.3.
P
5.3.7 Unattended
equipment
No thermostats, temperature
limiters or thermal cut-outs.
limiters or thermal cut-outs.
N/A
5.3.8
Compliance criteria for abnormal operating and
fault conditions
fault conditions
No fire or molten metal occurred
and no deformation of enclosure
during the tests.
and no deformation of enclosure
during the tests.
P
6
CONNECTION TO TELECOMMUNICATION NETWORKS
N/A
6.1
Protection of telecommunication network service persons, and users of other
equipment connected to the network, from hazards in the equipment
equipment connected to the network, from hazards in the equipment
N/A
6.1.1
Protection from hazardous voltages
N/A
6.1.2
Separation of the telecommunication network from earth
N/A
6.1.2.1 Requirements
No TNV circuitry.
N/A
Test
voltage
(V)
..................................................:
—
Current in the test circuit (mA) ..........................:
—
6.1.2.2 Exclusions...........................................................:
N/A
6.2
Protection of equipment users from overvoltages on telecommunication networks
N/A
6.2.1 Separation
requirements
No TNV circuitry.
N/A
6.2.2
Electric strength test procedure
N/A
6.2.2.1 Impulse
test
N/A
6.2.2.2 Steady-state
test
N/A
6.2.2.3 Compliance
criteria
N/A
6.3
Protection of the telecommunication wiring system from overheating
N/A
Max. output current (A) ....................................... :
No TNV circuitry.
—
Current limiting method....................................... :
—
7
CONNECTION TO CABLE DISTRIBUTION SYSTEMS
N/A
7.1
Protection of cable distribution system service
persons, and users of other equipment connected
to the system, from hazardous voltages in the
equipment
persons, and users of other equipment connected
to the system, from hazardous voltages in the
equipment
No CDS circuits.
N/A