JBL ON TOUR XTB (serv.man8) EMC - CB Certificate ▷ View online
- Page 29 of 57 -
www.nemko.com
Report No. 111547
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
7.2
Protection of equipment users from overvoltages
on the cable distribution system
on the cable distribution system
N/A
7.3
Insulation between primary circuits and cable
distribution systems
distribution systems
N/A
7.3.1 General
N/A
7.3.2
Voltage surge test
N/A
7.3.3 Impulse
test
N/A
A
ANNEX A, TESTS FOR RESISTANCE TO HEAT AND FIRE
N/A
A.1
Flammability test for fire enclosures of movable equipment having a total mass
exceeding 18 kg and of stationary equipment (see 4.7.3.2)
exceeding 18 kg and of stationary equipment (see 4.7.3.2)
N/A
A.1.1 Samples .............................................................. :
—
Wall thickness (mm)............................................ :
—
A.1.2
Conditioning of samples; temperature (
°C) ........:
N/A
A.1.3
Mounting of samples........................................... :
N/A
A.1.4 Test
flame
N/A
A.1.5 Test
procedure
N/A
A.1.6 Compliance
criteria
N/A
Sample 1 burning time (s)................................... :
—
Sample 2 burning time (s)................................... :
—
Sample 3 burning time (s)................................... :
—
A.2
Flammability test for fire enclosures of movable equipment having a total mass not
exceeding 18 kg, and for material and components located inside fire enclosures
(see 4.7.3.2 and 4.7.3.4)
exceeding 18 kg, and for material and components located inside fire enclosures
(see 4.7.3.2 and 4.7.3.4)
N/A
A.2.1 Samples,
material ............................................... :
—
Wall thickness (mm)............................................ :
—
A.2.2 Conditioning
of
samples
N/A
A.2.3
Mounting of samples
N/A
A.2.4 Test
flame
N/A
A.2.5 Test
procedure
N/A
A.2.6 Compliance
criteria
N/A
Sample 1 burning time (s)................................... :
—
Sample 2 burning time (s)................................... :
—
Sample 3 burning time (s)................................... :
—
A.2.7
Alternative test acc. to IEC 60695-2-2, cl. 4, 8
N/A
- Page 30 of 57 -
www.nemko.com
Report No. 111547
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
Sample 1 burning time (s)................................... :
—
Sample 2 burning time (s)................................... :
—
Sample 3 burning time (s)................................... :
—
A.3
Hot flaming oil test (see 4.6.2)
N/A
A.3.1
Mounting of samples
N/A
A.3.2
Test procedure
N/A
A.3.3 Compliance
criterion
N/A
B
ANNEX B, MOTOR TESTS UNDER ABNORMAL CONDITIONS (see 4.7.2.2 and
5.3.2)
5.3.2)
N/A
B.1 General
requirements
No motors in the equipment.
N/A
Position
.............................................................. :
—
Manufacturer
...................................................... :
—
Type
................................................................... :
—
Rated
values
..................................................... :
—
B.2 Test
conditions
N/A
B.3 Maximum
temperatures
N/A
B.4 Running
overload
test
N/A
B.5 Locked-rotor
overload
test
N/A
Test
duration
(days)
........................................... :
—
Electric strength test: test voltage (V) ................ :
—
B.6
Running overload test for d.c. motors in
secondary circuits
secondary circuits
N/A
B.7
Locked-rotor overload test for d.c. motors in secondary circuits
N/A
B.7.1
Test procedure
N/A
B.7.2
Alternative test procedure; test time (h)............... :
N/A
B.7.3
Electric strength test
N/A
B.8
Test for motors with capacitors
N/A
B.9
Test for three-phase motors
N/A
B.10
Test for series motors
N/A
Operating voltage (V) ......................................... :
—
C
ANNEX C, TRANSFORMERS (see 1.5.4 and 5.3.3)
N/A
- Page 31 of 57 -
www.nemko.com
Report No. 111547
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
Position
.............................................................. :
No transformers in the
equipment.
equipment.
—
Manufacturer
...................................................... :
—
Type
................................................................... :
—
Rated
values
..................................................... :
—
Method
of
protection ........................................... :
—
C.1 Overload
test
N/A
C.2 Insulation
N/A
Protection from displacement of windings .......... :
N/A
D
ANNEX D, MEASURING INSTRUMENTS FOR TOUCH-CURRENT TESTS (see
5.1.4)
5.1.4)
N/A
D.1 Measuring
instrument
Not used.
N/A
D.2 Alternative
measuring
instrument
N/A
E
ANNEX E, TEMPERATURE RISE OF A WINDING (see 1.4.13)
N/A
F
ANNEX F, MEASUREMENT OF CLEARANCES AND CREEPAGE DISTANCES
(see 2.10)
(see 2.10)
N/A
G
ANNEX G, ALTERNATIVE METHOD FOR DETERMINING MINIMUM
CLEARANCES
CLEARANCES
N/A
G.1
Summary of the procedure for determining
minimum clearances
minimum clearances
N/A
G.2
Determination of mains transient voltage (V) ..... :
N/A
G.2.1
AC mains supply
N/A
G.2.2
DC mains supply
N/A
G.3
Determination of telecommunication network
transient voltage (V)............................................ :
transient voltage (V)............................................ :
N/A
G.4
Determination of required withstand voltage (V) :
N/A
G.5
Measurement of transient voltage levels (V) ...... :
N/A
G.6
Determination of minimum clearances ............... :
N/A
H
ANNEX H, IONIZING RADIATION (see 4.3.13)
N/A
- Page 32 of 57 -
www.nemko.com
Report No. 111547
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
J
ANNEX J, TABLE OF ELECTROCHEMICAL POTENTIALS (see 2.6.5.6)
N/A
Metal used ........................................................... :
—
K
ANNEX K, THERMAL CONTROLS (see 1.5.3 and 5.3.7)
N/A
K.1
Making and breaking capacity
N/A
K.2
Thermostat reliability; operating voltage (V) ....... :
N/A
K.3
Thermostat endurance test; operating voltage
(V) ..................................................................... :
(V) ..................................................................... :
N/A
K.4
Temperature limiter endurance; operating voltage
(V) ...................................................................... :
(V) ...................................................................... :
N/A
K.5 Thermal
cut-out reliability
N/A
K.6 Stability
of
operation
N/A
L
ANNEX L, NORMAL LOAD CONDITIONS FOR SOME TYPES OF ELECTRICAL
BUSINESS EQUIPMENT (see 1.2.2.1 and 4.5.1)
BUSINESS EQUIPMENT (see 1.2.2.1 and 4.5.1)
N/A
L.1
Typewriters
N/A
L.2
Adding machines and cash registers
N/A
L.3 Erasers
N/A
L.4 Pencil
sharpeners
N/A
L.5
Duplicators and copy machines
N/A
L.6 Motor-operated
files
N/A
L.7 Other
business
equipment
N/A
M
ANNEX M, CRITERIA FOR TELEPHONE RINGING SIGNALS (see 2.3.1)
N/A
M.1 Introduction
N/A
M.2
Method A
N/A
M.3 Method
B
N/A
M.3.1 Ringing
signal
N/A
M.3.1.1 Frequency
(Hz)
.................................................. :
—
M.3.1.2 Voltage
(V)
......................................................... :
—
M.3.1.3
Cadence; time (s), voltage (V) ........................... :
—
M.3.1.4 Single
fault
current
(mA) ..................................... :
—
M.3.2
Tripping device and monitoring voltage .............. :
N/A
M.3.2.1
Conditions for use of a tripping device or a
monitoring voltage
monitoring voltage
N/A
Click on the first or last page to see other ON TOUR XTB (serv.man8) service manuals if exist.