JBL ON TOUR XTB (serv.man8) EMC - CB Certificate ▷ View online
- Page 13 of 57 -
www.nemko.com
Report No. 111547
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
1.6 Power
interface
N/A
1.6.1
AC power distribution systems
Class III equipment, not
connected to mains supply.
connected to mains supply.
N/A
1.6.2 Input
current
See appended table 1.6.2.
N/A
1.6.3
Voltage limit of hand-held equipment
Class III equipment.
N/A
1.6.4 Neutral
conductor
Class III equipment.
N/A
1.7
Markings and instructions
P
1.7.1
Power rating
Class III equipment not for direct
connection to a mains supply. No
electrical rating markings
required.
connection to a mains supply. No
electrical rating markings
required.
P
Rated voltage(s) or voltage range(s) (V) ........... :
12Vdc
N/A
Symbol for nature of supply, for d.c. only ........... :
Not for connection to D.C. mains
supply.
supply.
N/A
Rated frequency or rated frequency range (Hz) :
N/A
Rated current (mA or A) ..................................... :
1.25A
N/A
Manufacturer’s name or trademark or
identification mark .............................................. :
identification mark .............................................. :
P
Type/model or type reference............................. :
On Tour XTB
P
Symbol for Class II equipment only ................... :
Class III equipment.
N/A
Other
symbols
.................................................... :
The additional marking does not
give rise to misunderstandings.
give rise to misunderstandings.
P
Certification
marks
............................................. :
Refer to Copy of marking plate.
P
1.7.2 Safety
instructions
Provided with marking regarding
use of specified power supply,
refer to copy of marking plate.
use of specified power supply,
refer to copy of marking plate.
P
1.7.3
Short duty cycles
The equipment is intended for
continuous operation.
continuous operation.
N/A
1.7.4 Supply
voltage
adjustment
................................. :
No voltage selector.
N/A
1.7.5
Power outlets on the equipment ........................ :
No standard power outlet.
N/A
1.7.6 Fuse
identification
.............................................. :
N/A
1.7.7 Wiring
terminals
Class III equipment.
N/A
1.7.7.1
Protective earthing and bonding terminals ........ :
N/A
1.7.7.2
Terminal for a.c. mains supply conductors
N/A
1.7.7.3
Terminals for d.c. mains supply conductors
N/A
- Page 14 of 57 -
www.nemko.com
Report No. 111547
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
1.7.8 Controls
and
indicators
Unit is provided with a secondary
push power switch.
push power switch.
P
1.7.8.1
Identification, location and marking ................... :
N/A
1.7.8.2 Colours
............................................................... :
N/A
1.7.8.3 Symbols
............................................................ :
Secondary power push button
marked with the standby symbol
(IEC 60417, No. 5010).
marked with the standby symbol
(IEC 60417, No. 5010).
P
1.7.8.4
Markings using figures ...................................... :
N/A
1.7.9
Isolation of multiple power sources .................... :
Class III equipment for supply
from a SELV, LPS power source.
from a SELV, LPS power source.
N/A
1.7.10
IT power distribution systems
Class III equipment for supply
from a SELV, LPS power source.
from a SELV, LPS power source.
N/A
1.7.11
Thermostats and other regulating devices
No thermostats or other
regulating devices.
regulating devices.
N/A
1.7.12 Language
........................................................... :
Instructions and markings shall
be in a language acceptable for
the country where the equipment
is to be used.
be in a language acceptable for
the country where the equipment
is to be used.
—
1.7.13 Durability
The marking withstands required
tests.
tests.
P
1.7.14 Removable
parts
No marking is placed on
removable parts.
removable parts.
N/A
1.7.15 Replaceable
batteries
Equipment can be powered by
consumer grade AA, alkaline
batteries, which are considered
inherently safe. Refer to
Summary of Testing and
appended table 4.3.8.
consumer grade AA, alkaline
batteries, which are considered
inherently safe. Refer to
Summary of Testing and
appended table 4.3.8.
P
Language ............................................................ :
English
—
1.7.16
Operator access with a tool ................................ :
No operator access with a tool.
N/A
1.7.17
Equipment for restricted access locations .......... :
Equipment not intended for
installation in RAL.
installation in RAL.
N/A
2 PROTECTION
FROM
HAZARDS
N/A
2.1
Protection from electric shock and energy hazards
N/A
2.1.1
Protection in operator access areas
Refer below:
N/A
2.1.1.1
Access to energized parts
Class III equipment. No
hazardous voltage or energy
supplied to equipment.
hazardous voltage or energy
supplied to equipment.
N/A
Test by inspection .............................................. :
N/A
- Page 15 of 57 -
www.nemko.com
Report No. 111547
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
Test with test finger ............................................ :
N/A
Test with test pin ................................................ :
N/A
Test with test probe ............................................ :
N/A
2.1.1.2 Battery
compartments
........................................ :
No TNV circuits in the
equipment.
equipment.
N/A
2.1.1.3
Access to ELV wiring
No internal wiring at ELV.
N/A
Working
voltage
(V);
minimum distance (mm)
through insulation
—
2.1.1.4
Access to hazardous voltage circuit wiring
Class III equipment. No
hazardous voltage supplied to
equipment.
hazardous voltage supplied to
equipment.
N/A
2.1.1.5 Energy
hazards
.................................................. :
Class III equipment for supply
from LPS source. No energy
hazard in operator access area.
from LPS source. No energy
hazard in operator access area.
N/A
2.1.1.6 Manual
controls
No shafts of knobs etc. at ELV or
hazardous voltage.
hazardous voltage.
N/A
2.1.1.7
Discharge of capacitors in equipment
Class III equipment. Not intended
for connection to AC mains
supply.
for connection to AC mains
supply.
N/A
Time-constant (s); measured voltage (V) ........... :
—
2.1.2
Protection in service access areas
Class III equipment. No
hazardous voltage supplied to
equipment. No bare parts at
hazardous energy level.
hazardous voltage supplied to
equipment. No bare parts at
hazardous energy level.
N/A
2.1.3
Protection in restricted access locations
Equipment not intended for
installation in RAL.
installation in RAL.
N/A
2.2 SELV
circuits
P
2.2.1 General
requirements
Class III equipment intended to
be power from separately
certified SELV source.
SELV limits are not exceeded
under normal condition and after
a single fault.
be power from separately
certified SELV source.
SELV limits are not exceeded
under normal condition and after
a single fault.
P
2.2.2
Voltages under normal conditions (V)................. :
Within SELV limits.
P
2.2.3
Voltages under fault conditions (V)..................... :
Within SELV limits. Powered by
Limited Power Source
Limited Power Source
.
P
2.2.3.1
Separation by double insulation or reinforced
insulation (method 1)
insulation (method 1)
N/A
2.2.3.2
Separation by earthed screen (method 2)
N/A
- Page 16 of 57 -
www.nemko.com
Report No. 111547
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
2.2.3.3
Protection by earthing of the SELV circuit
(method 3)
(method 3)
N/A
2.2.4
Connection of SELV circuits to other circuits....... :
SELV circuits are only connected
to other SELV circuits and
protective earth.
to other SELV circuits and
protective earth.
P
2.3 TNV
circuits
N/A
2.3.1 Limits
No TNV circuits.
N/A
Type of TNV circuits............................................ :
—
2.3.2
Separation from other circuits and from
accessible parts
accessible parts
N/A
Insulation
employed ............................................ :
—
2.3.3 Separation
from
hazardous
voltages
N/A
Insulation
employed ............................................ :
—
2.3.4
Connection of TNV circuits to other circuits
N/A
Insulation
employed ............................................ :
—
2.3.5
Test for operating voltages generated externally
N/A
2.4 Limited
current
circuits
N/A
2.4.1 General
requirements
No limited current circuits.
N/A
2.4.2 Limit
values
N/A
Frequency
(Hz) ................................................... :
—
Measured
current
(mA)....................................... :
—
Measured
voltage
(V).......................................... :
—
Measured capacitance (
μF) ................................ :
—
2.4.3
Connection of limited current circuits to other
circuits
circuits
N/A
2.5 Limited
power
sources
P