- Page 13 of 57 - 
 
 
www.nemko.com
 
Report No.  111547 
 
 
TRF No.:IECEN60950_1B 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict
 
1.6 Power 
interface 
N/A
 
1.6.1 
AC power distribution systems 
Class III equipment, not 
connected to mains supply.  
N/A
 
1.6.2 Input 
current 
See appended table 1.6.2. 
N/A
 
1.6.3 
Voltage limit of hand-held equipment 
Class III equipment.
 
N/A
 
1.6.4 Neutral 
conductor 
 
Class III equipment.
 
N/A
 
 
1.7 
Markings and instructions 
P
 
1.7.1 
Power rating  
Class III equipment not for direct 
connection to a mains supply. No 
electrical rating markings 
required. 
 
P
 
 
Rated voltage(s) or voltage range(s) (V)  ........... : 
12Vdc 
N/A
 
 
Symbol for nature of supply, for d.c. only ........... : 
Not for connection to D.C. mains 
supply. 
N/A
 
 
Rated frequency or rated frequency range (Hz)  : 
 
N/A
 
 
Rated current (mA or A) ..................................... : 
1.25A 
N/A
 
 
Manufacturer’s name or trademark or 
identification mark  .............................................. : 
 
P
 
 
Type/model or type reference............................. : 
On Tour XTB 
P
 
 
Symbol for Class II equipment only  ................... : 
Class III equipment. 
N/A
 
 Other 
symbols 
.................................................... : 
The additional marking does not 
give rise to misunderstandings.
 
P
 
 Certification 
marks 
............................................. : 
Refer to Copy of marking plate.
 
P
 
1.7.2 Safety 
instructions 
Provided with marking regarding 
use of specified power supply, 
refer to copy of marking plate.
 
P
 
1.7.3 
Short duty cycles 
The equipment is intended for 
continuous operation.
 
N/A
 
1.7.4 Supply 
voltage 
adjustment 
................................. : 
No voltage selector.
 
N/A
 
1.7.5 
Power outlets on the equipment  ........................ : 
No standard power outlet.
 
N/A
 
1.7.6 Fuse 
identification 
.............................................. : 
 
N/A
 
1.7.7 Wiring 
terminals 
Class III equipment.
 
N/A
 
1.7.7.1 
Protective earthing and bonding terminals  ........ :   
N/A
 
1.7.7.2 
Terminal for a.c. mains supply conductors  
 
N/A
 
1.7.7.3 
Terminals for d.c. mains supply conductors 
 
N/A
 
 
 
- Page 14 of 57 - 
 
 
www.nemko.com
 
Report No.  111547 
 
 
TRF No.:IECEN60950_1B 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict
1.7.8 Controls 
and 
indicators 
Unit is provided with a secondary 
push power switch.
 
P
 
1.7.8.1 
Identification, location and marking  ................... :   
N/A
 
1.7.8.2 Colours 
............................................................... : 
 
N/A
 
1.7.8.3 Symbols 
 
............................................................ : 
Secondary power push button 
marked with the standby symbol 
(IEC 60417, No. 5010). 
P
 
1.7.8.4 
Markings using figures  ...................................... :   
N/A
 
1.7.9 
Isolation of multiple power sources .................... : 
Class III equipment for supply 
from a SELV, LPS power source. 
N/A
 
1.7.10 
IT power distribution systems  
Class III equipment for supply 
from a SELV, LPS power source.
N/A
 
1.7.11 
Thermostats and other regulating devices  
No thermostats or other 
regulating devices. 
 
N/A
 
1.7.12 Language 
........................................................... : 
Instructions and markings shall 
be in a language acceptable for 
the country where the equipment 
is to be used.
 
— 
1.7.13 Durability 
The marking withstands required 
tests.
 
P
 
1.7.14 Removable 
parts 
No marking is placed on 
removable parts.
 
N/A
 
1.7.15 Replaceable 
batteries 
Equipment can be powered by 
consumer grade AA, alkaline 
batteries, which are considered 
inherently safe. Refer to 
Summary of Testing and 
appended table 4.3.8. 
 
P
 
 Language ............................................................ : 
English
 
— 
1.7.16 
Operator access with a tool ................................ : 
No operator access with a tool. 
N/A
 
1.7.17 
Equipment for restricted access locations .......... : 
Equipment not intended for 
installation in RAL. 
N/A
 
 
2 PROTECTION 
FROM 
HAZARDS 
N/A
 
2.1 
Protection from electric shock and energy hazards 
N/A
 
2.1.1 
Protection in operator access areas  
Refer below:
 
N/A
 
2.1.1.1 
Access to energized parts 
Class III equipment. No 
hazardous voltage or energy 
supplied to equipment.
 
 
N/A
 
 
Test by inspection  .............................................. : 
 
N/A
 
 
 
- Page 15 of 57 - 
 
 
www.nemko.com
 
Report No.  111547 
 
 
TRF No.:IECEN60950_1B 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict
 
Test with test finger ............................................ : 
 
N/A
 
 
Test with test pin  ................................................ : 
 
N/A
 
 
Test with test probe ............................................ : 
 
N/A
 
2.1.1.2 Battery 
compartments 
........................................ : 
No TNV circuits in the 
equipment. 
N/A
 
2.1.1.3 
Access to ELV wiring 
No internal wiring at ELV. 
N/A
 
 Working 
voltage 
(V); 
minimum distance (mm) 
through insulation 
 
— 
2.1.1.4 
Access to hazardous voltage circuit wiring 
Class III equipment. No 
hazardous voltage supplied to 
equipment. 
 
N/A
 
2.1.1.5 Energy 
hazards 
.................................................. : 
Class III equipment for supply 
from LPS source. No energy 
hazard in operator access area.
 
N/A
 
2.1.1.6 Manual 
controls 
No shafts of knobs etc. at ELV or 
hazardous voltage.
 
N/A
 
2.1.1.7 
Discharge of capacitors in equipment 
Class III equipment. Not intended 
for connection to AC mains 
supply. 
 
N/A
 
 
Time-constant (s); measured voltage (V) ........... :   
— 
2.1.2 
Protection in service access areas 
Class III equipment. No 
hazardous voltage supplied to 
equipment. No bare parts at 
hazardous energy level.
 
N/A
 
2.1.3 
Protection in restricted access locations 
Equipment not intended for 
installation in RAL.
 
N/A
 
 
2.2 SELV 
circuits 
P
 
2.2.1 General 
requirements 
Class III equipment intended to 
be power from separately 
certified SELV source. 
SELV limits are not exceeded 
under normal condition and after 
a single fault.
 
P
 
2.2.2 
Voltages under normal conditions (V)................. : 
Within SELV limits.
 
P
 
2.2.3 
Voltages under fault conditions (V)..................... : 
Within SELV limits. Powered by 
Limited Power Source
P
 
2.2.3.1 
Separation by double insulation or reinforced 
insulation (method 1) 
 
N/A
 
2.2.3.2 
Separation by earthed screen (method 2) 
 
N/A
 
 
 
- Page 16 of 57 - 
 
 
www.nemko.com
 
Report No.  111547 
 
 
TRF No.:IECEN60950_1B 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict
2.2.3.3 
Protection by earthing of the SELV circuit 
(method 3) 
 
N/A
 
2.2.4 
Connection of SELV circuits to other circuits....... :
SELV circuits are only connected 
to other SELV circuits and 
protective earth.
 
P
 
 
2.3 TNV 
circuits 
N/A
 
2.3.1 Limits 
No TNV circuits.
 
N/A
 
 
Type of TNV circuits............................................ :   
— 
2.3.2 
Separation from other circuits and from 
accessible parts 
 
N/A
 
 Insulation 
employed ............................................ : 
 
— 
2.3.3 Separation 
from 
hazardous 
voltages 
 
N/A
 
 Insulation 
employed ............................................ : 
 
— 
2.3.4 
Connection of TNV circuits to other circuits 
 
N/A
 
 Insulation 
employed ............................................ : 
 
— 
2.3.5 
Test for operating voltages generated externally 
 
N/A
 
 
2.4 Limited 
current 
circuits 
N/A
 
2.4.1 General 
requirements 
No limited current circuits. 
N/A
 
2.4.2 Limit 
values 
 
N/A
 
 Frequency 
(Hz) ................................................... : 
 
— 
 Measured 
current 
(mA)....................................... : 
 
— 
 Measured 
voltage 
(V).......................................... : 
 
— 
 
Measured capacitance (
μF) ................................ : 
 
— 
2.4.3 
Connection of limited current circuits to other 
circuits 
 
N/A
 
 
2.5 Limited 
power 
sources 
P
 