JBL ON STAGEII (serv.man12) EMC - CB Certificate ▷ View online
- Page 25 of 52 -
www.nemko.com
Report No. 46974
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
5.1.8
Touch currents to telecommunication networks
and cable distribution systems and from
telecommunication networks
and cable distribution systems and from
telecommunication networks
No TNV or CDS.
N/A
5.1.8.1
Limitation of the touch current to a
telecommunication network and a cable
distribution system
telecommunication network and a cable
distribution system
—
Test voltage (V) ................................................. :
—
Measured touch current (mA) ........................... :
—
Max. allowed touch current (mA) ...................... :
—
5.1.8.2
Summation of touch currents from
telecommunication networks.............................. :
telecommunication networks.............................. :
—
5.2 Electric
strength
—
5.2.1
General
Functional insulation, no test
required.
required.
N/A
5.2.2 Test
procedure
N/A
5.3
Abnormal operating and fault conditions
—
5.3.1
Protection against overload and abnormal
operation
operation
(see appended table 5.3)
P
5.3.2
Motors
There are no motors in the
equipment.
equipment.
N/A
5.3.3
Transformers
There are no safety
transformers in the equipment.
transformers in the equipment.
N/A
5.3.4
Functional insulation ...........................................: Complies with c), mounted on
V-1 or better material.
P
5.3.5 Electromechanical
components
No
electromechanical
components in secondary
circuits.
circuits.
N/A
5.3.6
Simulation of faults
(see appended table 5.3)
P
5.3.7
Unattended equipment
No thermostats, temperature
limiters or thermal cut-outs
limiters or thermal cut-outs
N/A
5.3.8
Compliance criteria for abnormal operating and
fault conditions
fault conditions
No fire or molten metal
occurred and no deformation of
enclosure during the tests.
occurred and no deformation of
enclosure during the tests.
P
6
CONNECTION TO TELECOMMUNICATION NETWORKS
N/A
6.1
Protection of telecommunication network service persons, and users of other
equipment connected to the network, from hazards in the equipment
equipment connected to the network, from hazards in the equipment
—
- Page 26 of 52 -
www.nemko.com
Report No. 46974
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
6.1.1
Protection from hazardous voltages
—
6.1.2
Separation of the telecommunication network from earth
—
6.1.2.1
Requirements
No TNV circuits in the
equipment.
equipment.
—
Test voltage (V) ................................................. :
—
Current in the test circuit (mA) ......................... :
—
6.1.2.2 Exclusions .......................................................... :
—
6.2
Protection of equipment users from overvoltages on telecommunication networks
N/A
6.2.1
Separation requirements
No TNV circuits in the
equipment.
equipment.
—
6.2.2
Electric strength test procedure
—
6.2.2.1 Impulse
test
—
6.2.2.2 Steady-state
test
—
6.2.2.3 Compliance
criteria
—
6.3
Protection of the telecommunication wiring system from overheating
—
Max.
output
current
(A) .......................................:
—
Current
limiting
method .......................................:
—
7
CONNECTION TO CABLE DISTRIBUTION SYSTEMS
N/A
7.1
Protection of cable distribution system service
persons, and users of other equipment connected
to the system, from hazardous voltages in the
equipment
persons, and users of other equipment connected
to the system, from hazardous voltages in the
equipment
No CDS circuits in the
equipment.
equipment.
—
7.2
Protection of equipment users from overvoltages
on the cable distribution system
on the cable distribution system
—
7.3
Insulation between primary circuits and cable
distribution systems
distribution systems
—
7.3.1 General
—
7.3.2 Voltage
surge
test
—
7.3.3 Impulse
test
—
A
ANNEX A, TESTS FOR RESISTANCE TO HEAT AND FIRE
N/A
A.1 Flammability
test
for fire enclosures of movable equipment having a total mass
exceeding 18 kg and of stationary equipment (see 4.7.3.2)
—
- Page 27 of 52 -
www.nemko.com
Report No. 46974
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
A.1.1
Samples ..............................................................: All materials have suitable
flame class, no testing
required.
required.
—
Wall thickness (mm)............................................:
—
A.1.2
Conditioning of samples; temperature (
°C).........:
—
A.1.3
Mounting of samples ...........................................:
—
A.1.4 Test
flame
—
A.1.5 Test
procedure
—
A.1.6 Compliance
criteria
—
Sample 1 burning time (s)...................................:
—
Sample 2 burning time (s)...................................:
—
Sample 3 burning time (s)...................................:
—
A.2 Flammability
test
for fire enclosures of movable equipment having a total mass not
exceeding 18 kg, and for material and components located inside fire enclosures
(see 4.7.3.2 and 4.7.3.4)
(see 4.7.3.2 and 4.7.3.4)
—
A.2.1 Samples,
material ...............................................:
—
Wall thickness (mm)............................................:
—
A.2.2
Conditioning of samples
—
A.2.3
Mounting of samples
—
A.2.4 Test
flame
—
A.2.5 Test
procedure
—
A.2.6 Compliance
criteria
—
Sample 1 burning time (s)...................................:
—
Sample 2 burning time (s)...................................:
—
Sample 3 burning time (s)...................................:
—
A.2.7
Alternative test acc. to IEC 60695-2-2, cl. 4, 8
—
Sample 1 burning time (s)...................................:
—
Sample 2 burning time (s)...................................:
—
Sample 3 burning time (s)...................................:
—
A.3
Hot flaming oil test (see 4.6.2)
—
A.3.1
Mounting of samples
—
A.3.2
Test procedure
—
A.3.3 Compliance
criterion
—
- Page 28 of 52 -
www.nemko.com
Report No. 46974
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
B
ANNEX B, MOTOR TESTS UNDER ABNORMAL CONDITIONS (see 4.7.2.2 and
5.3.2)
5.3.2)
N/A
B.1 General
requirements
No
motors.
—
Position
............................................................... :
—
Manufacturer
...................................................... :
—
Type
................................................................... :
—
Rated values ..................................................... :
—
B.2 Test
conditions
—
B.3 Maximum
temperatures
—
B.4 Running
overload
test
—
B.5
Locked-rotor overload test
—
Test duration (days) ........................................... :
—
Electric strength test: test voltage (V) ................ :
—
B.6
Running overload test for d.c. motors in
secondary circuits
secondary circuits
—
B.7
Locked-rotor overload test for d.c. motors in secondary circuits
—
B.7.1
Test procedure
—
B.7.2
Alternative test procedure; test time (h) ............... :
—
B.7.3
Electric strength test
—
B.8
Test for motors with capacitors
—
B.9
Test for three-phase motors
—
B.10
Test for series motors
—
Operating
voltage
(V)
......................................... :
—
C
ANNEX C, TRANSFORMERS (see 1.5.4 and 5.3.3)
N/A
Position ............................................................... : No isolating transformers.
—
Manufacturer
...................................................... :
—
Type
................................................................... :
—
Rated values ..................................................... :
—
Method of protection ...........................................:
—
C.1 Overload
test
—
C.2 Insulation
—
Protection from displacement of windings...........:
—