JBL ON STAGEII (serv.man12) EMC - CB Certificate ▷ View online

 
 
- Page 37 of 52 - 
 
 
www.nemko.com
 
Report No.  46974 
 
 
TRF No.:IECEN60950_1B 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
3.2.1.1 
S (ES): Supply cords of single-phase equipment 
having a rated current not exceeding 10 A shall 
be provided with a plug according to 
UNE 20315:1994. 
Supply cords of single-phase equipment having a 
rated current not exceeding 2,5 A shall be 
provided with a plug according to 
UNE-EN 50075:1993. 
C
LASS 
I
 EQUIPMENT
 provided with socket-outlets 
with earth contacts or which are intended to be 
used in locations where protection against 
indirect contact is required according to the 
wiring rules, shall be provided with a plug in 
accordance with standard UNE 20315:1994. 
If poly-phase equipment is provided with a supply 
cord with a plug, this plug shall be in accordance 
with UNE-EN 60309-2. 
Class III equipment. Unit is not 
intended for direct connection 
to a mains supply. 
N/A 
3.2.1.1 
S (GB): Apparatus which is fitted with a flexible 
cable or cord and is designed to be connected to 
a mains socket conforming to BS 1363 by means 
of that flexible cable or cord and plug, shall be 
fitted with a 'standard plug' in accordance with 
Statutory Instrument 1768:1994 – The Plugs and 
Socket etc. (Safety) Regulations 1994, unless 
exempted by those regulations. 
NOTE – 'Standard plug' is defined in SI 1768:1994 and 
essentially means an approved plug conforming to BS 1363 
or an approved conversion plug. 
 
Class III equipment. Unit is not 
intended for direct connection 
to a mains supply. 
N/A 
3.2.1.1 
S (IE): Apparatus which is fitted with a flexible 
cable or cord and is designed to be connected to 
a mains socket conforming to I.S. 411 by means 
of that flexible cable or cord and plug, shall be 
fitted with a 13 A plug in accordance with 
Statutory Instrument 525:1997 – National 
Standards Authority of Ireland (section 28) (13 A 
Plugs and Conversion Adaptors for Domestic 
Use) Regulations 1997. 
Class III equipment. Unit is not 
intended for direct connection 
to a mains supply. 
N/A 
3.2.3 
C: Delete Note 1 and in Table 3A, delete the 
conduit sizes in parentheses. 
Considered. 
— 
 
 
- Page 38 of 52 - 
 
 
www.nemko.com
 
Report No.  46974 
 
 
TRF No.:IECEN60950_1B 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
3.2.5.1 C: 
Replace 
"60245 IEC 53"  by "H05 RR-F"; 
"60227 IEC 52"  by "H03 VV-F or H03 VVH2-F"; 
"60227 IEC 53"  by "H05 VV-F or H05 VVH2-F2".
In Table 3B, replace the first four lines by the 
following: 
Up to and including 6  
 
0,75
1)
 
Over 6 up to and including 10  (0,75)
2) 
1,0 
Over 10 up to and including 16 (1,0)
3)
 1,5 
In the Conditions applicable to Table 3B delete 
the words "in some countries" in condition 
1)
In Note 1, applicable to Table 3B, delete the 
second sentence. 
Considered. N/A 
3.2.5.1 
S (GB): A power supply cord with conductor of 
1,25 mm
2
 is allowed for equipment with a rated 
current over 10 A and up to and including 13 A. 
Class III equipment. Unit is not 
intended for direct connection 
to a mains supply. 
N/A 
3.3.4 
C: In Table 3D, delete the fourth line: conductor 
sizes for 10 to 13A, and replace with the 
following: 
Over 10 up to and including 16  1,5 to 2,5 1,5 to 

Delete the fifth line: conductor sizes for 13 to 
16 A. 
Class III equipment. Unit is not 
intended for direct connection 
to a mains supply. 
N/A 
3.3.4 
S (GB): The range of conductor sizes of flexible 
cords to be accepted by terminals for equipment 
with a
 RATED CURRENT
 of over 10 A up to and 
including 13 A is: 
- 1,25 mm
2
 to 1,5 mm
2
 nominal cross-sectional 
area. 
Class III equipment. Unit is not 
intended for direct connection 
to a mains supply. 
N/A 
4.3.6 
S (GB): The torque test is performed using a 
socket outlet complying with BS 1363 and the 
plug part of 
DIRECT PLUG
-
IN EQUIPMENT
 shall be 
assessed to BS 1363: Part 1, 12.1, 12.2, 12.3, 
12.9, 12.11, 12.12, 12.16 and 12.17, except that 
the test of 12.17 is performed at not less than 
125
°C. 
Not a Direct Plug-In Equipment.
N/A 
 
S (IE): D
IRECT PLUG
-
IN EQUIPMENT
 is known as 
plug similar devices. Such devices shall comply 
with Statutory Instrument 526:1997 – National 
Standards Authority of Ireland (Section 28) 
(Electrical plugs, plug similar devices and 
sockets for domestic use) Regulations, 1997. 
Not provided with Irish plug. 
 
N/A 
 
 
- Page 39 of 52 - 
 
 
www.nemko.com
 
Report No.  46974 
 
 
TRF No.:IECEN60950_1B 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
4.3.13.6 
C: Add the following note: 
NOTE  Attention is drawn to 1999/519/EC: Council 
Recommendation on the limitation of exposure of the general 
public to electromagnetic fields 0 Hz to 300 GHz. Standards 
taking into account this Recommendation are currently under 
development. 
Considered. N/A 
6.1.2.1 
S (FI, NO, SE): Add the following text between 
the first and second paragraph: 
If this insulation is solid, including insulation 
forming part of a component, it shall at least 
consist of either 
- two layers of thin sheet material, each of which 
shall pass the electric strength test below, or 
- one layer having a distance through insulation 
of at least 0,4 mm, which shall pass the electric 
strength test below. 
If this insulation forms part of a semiconductor 
component (e.g. an optocoupler), there is no 
distance through insulation requirement for the 
insulation consisting of an insulating compound 
completely filling the casing, so that 
CLEARANCES 
and
 CREEPAGE DISTANCES
 do not exist, if the 
component passes the electric strength test in 
accordance with the compliance clause below 
and in addition 
- passes the tests and inspection criteria of 
2.10.8 with an electric strength test of 1,5 kV 
multiplied by 1,6 (the electric strength test of 
2.10.7 shall be performed using 1,5 kV), and 
- is subject to 
ROUTINE TESTING
 for electric 
strength during manufacturing, using a test 
voltage of 1,5 kV. 
It is permitted to bridge this insulation with a 
capacitor complying with EN 132400:1994, 
subclass Y2. 
A capacitor classified Y3 according to 
EN 132400:1994, may bridge this insulation 
under the following conditions: 
- the insulation requirements are satisfied by 
having a capacitor classified Y3 as defined by 
EN 132400, which in addition to the Y3 testing, is 
tested with an impulse test of 2,5 kV defined in 
EN 60950:2000, 6.2.2.1; 
- the additional testing shall be performed on all 
the test specimens as described in EN 132400; 
- the impulse test of 2,5 kV is to be performed 
No TNV circuits. 
N/A 
 
 
- Page 40 of 52 - 
 
 
www.nemko.com
 
Report No.  46974 
 
 
TRF No.:IECEN60950_1B 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
before the endurance test in EN 132400, in the 
sequence of tests as described in EN 132400. 
6.1.2.2 
S (FI, NO, SE): The exclusions are applicable for 
PERMANENTLY CONNECTED EQUIPMENT
 and
 
PLUGGABLE EQUIPMENT TYPE 
B and equipment 
intended to be used in a 
RESTRICTED ACCESS 
LOCATION
 where equipotential bonding has been 
applied, e.g. in a telecommunication centre, and 
which has provision for a permanently connected 
PROTECTIVE EARTHING CONDUCTOR 
and is provided 
with instructions for the installation of that 
conductor by a service person. 
No TNV circuits. 
N/A 
7.1 
S (FI, NO, SE): Requirements according to this 
annex, 6.1.2.1 and 6.1.2.2 apply with the term 
TELECOMMUNICATION NETWORK
 in 6.1.2 being 
replaced by the term 
CABLE DISTRIBUTION SYSTEM
Not for connection to cable 
distribution systems. 
N/A 
G.2.1 
S (NO): Due to the IT power distribution system 
used (see annex V, Fig. V.7), the 
A
.
C
.
 MAINS 
SUPPLY
 voltage is considered to be equal to the 
line-to-line voltage, and will remain at 230 V in 
case of a single earth fault. 
Not used. 
N/A 
Annex H 
C: Replace the last paragraph of this annex by: 
At any point 10 cm from the surface of the 
OPERATOR ACCESS AREA
, the dose rate shall not 
exceed 1 
µSv/h (0,1 mR/h) (see note). Account is 
taken of the background level. 
Replace the notes as follows: 
NOTE  These values appear in Directive 96/29/Euratom. 
 
Delete Note 2. 
The unit does not emit X-ray 
radiation. 
N/A 
Annex H 
A (DE, Regulation on protection against hazards 
by X-ray, of 8
th
 January 1987, Article 5 
[Operation of X-ray emission source], clauses 1 
to 4): 
a) A licence is required by those who operate an 
X-ray emission source. 
b) A licence in accordance with clause 1 is not 
required by those who operate an X-ray emission 
source on which the electron acceleration voltage 
does not exceed 20 kV if 
  1) the local dose rate at a distance of 0,1 m 
from the surface does not exceed 1 µSv/h and 
  2) it is adequately indicated on the X-ray 
emission source that 
  i)  X-rays are generated, and 
  ii)  the electron acceleration voltage must not 
German A deviation withdrawn 
according to Amd. A11:2004. 
N/A 