JBL ON STAGEII (serv.man12) EMC - CB Certificate ▷ View online
- Page 37 of 52 -
www.nemko.com
Report No. 46974
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
3.2.1.1
S (ES): Supply cords of single-phase equipment
having a rated current not exceeding 10 A shall
be provided with a plug according to
UNE 20315:1994.
Supply cords of single-phase equipment having a
rated current not exceeding 2,5 A shall be
provided with a plug according to
UNE-EN 50075:1993.
C
having a rated current not exceeding 10 A shall
be provided with a plug according to
UNE 20315:1994.
Supply cords of single-phase equipment having a
rated current not exceeding 2,5 A shall be
provided with a plug according to
UNE-EN 50075:1993.
C
LASS
I
EQUIPMENT
provided with socket-outlets
with earth contacts or which are intended to be
used in locations where protection against
indirect contact is required according to the
wiring rules, shall be provided with a plug in
accordance with standard UNE 20315:1994.
If poly-phase equipment is provided with a supply
cord with a plug, this plug shall be in accordance
with UNE-EN 60309-2.
used in locations where protection against
indirect contact is required according to the
wiring rules, shall be provided with a plug in
accordance with standard UNE 20315:1994.
If poly-phase equipment is provided with a supply
cord with a plug, this plug shall be in accordance
with UNE-EN 60309-2.
Class III equipment. Unit is not
intended for direct connection
to a mains supply.
intended for direct connection
to a mains supply.
N/A
3.2.1.1
S (GB): Apparatus which is fitted with a flexible
cable or cord and is designed to be connected to
a mains socket conforming to BS 1363 by means
of that flexible cable or cord and plug, shall be
fitted with a 'standard plug' in accordance with
Statutory Instrument 1768:1994 – The Plugs and
Socket etc. (Safety) Regulations 1994, unless
exempted by those regulations.
cable or cord and is designed to be connected to
a mains socket conforming to BS 1363 by means
of that flexible cable or cord and plug, shall be
fitted with a 'standard plug' in accordance with
Statutory Instrument 1768:1994 – The Plugs and
Socket etc. (Safety) Regulations 1994, unless
exempted by those regulations.
NOTE – 'Standard plug' is defined in SI 1768:1994 and
essentially means an approved plug conforming to BS 1363
or an approved conversion plug.
essentially means an approved plug conforming to BS 1363
or an approved conversion plug.
Class III equipment. Unit is not
intended for direct connection
to a mains supply.
intended for direct connection
to a mains supply.
N/A
3.2.1.1
S (IE): Apparatus which is fitted with a flexible
cable or cord and is designed to be connected to
a mains socket conforming to I.S. 411 by means
of that flexible cable or cord and plug, shall be
fitted with a 13 A plug in accordance with
Statutory Instrument 525:1997 – National
Standards Authority of Ireland (section 28) (13 A
Plugs and Conversion Adaptors for Domestic
Use) Regulations 1997.
cable or cord and is designed to be connected to
a mains socket conforming to I.S. 411 by means
of that flexible cable or cord and plug, shall be
fitted with a 13 A plug in accordance with
Statutory Instrument 525:1997 – National
Standards Authority of Ireland (section 28) (13 A
Plugs and Conversion Adaptors for Domestic
Use) Regulations 1997.
Class III equipment. Unit is not
intended for direct connection
to a mains supply.
intended for direct connection
to a mains supply.
N/A
3.2.3
C: Delete Note 1 and in Table 3A, delete the
conduit sizes in parentheses.
conduit sizes in parentheses.
Considered.
—
- Page 38 of 52 -
www.nemko.com
Report No. 46974
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
3.2.5.1 C:
Replace
"60245 IEC 53" by "H05 RR-F";
"60227 IEC 52" by "H03 VV-F or H03 VVH2-F";
"60227 IEC 53" by "H05 VV-F or H05 VVH2-F2".
In Table 3B, replace the first four lines by the
following:
Up to and including 6
"60227 IEC 52" by "H03 VV-F or H03 VVH2-F";
"60227 IEC 53" by "H05 VV-F or H05 VVH2-F2".
In Table 3B, replace the first four lines by the
following:
Up to and including 6
0,75
1)
Over 6 up to and including 10 (0,75)
2)
1,0
Over 10 up to and including 16 (1,0)
3)
1,5
In the Conditions applicable to Table 3B delete
the words "in some countries" in condition
the words "in some countries" in condition
1)
.
In Note 1, applicable to Table 3B, delete the
second sentence.
second sentence.
Considered. N/A
3.2.5.1
S (GB): A power supply cord with conductor of
1,25 mm
1,25 mm
2
is allowed for equipment with a rated
current over 10 A and up to and including 13 A.
Class III equipment. Unit is not
intended for direct connection
to a mains supply.
intended for direct connection
to a mains supply.
N/A
3.3.4
C: In Table 3D, delete the fourth line: conductor
sizes for 10 to 13A, and replace with the
following:
Over 10 up to and including 16 1,5 to 2,5 1,5 to
4
Delete the fifth line: conductor sizes for 13 to
16 A.
sizes for 10 to 13A, and replace with the
following:
Over 10 up to and including 16 1,5 to 2,5 1,5 to
4
Delete the fifth line: conductor sizes for 13 to
16 A.
Class III equipment. Unit is not
intended for direct connection
to a mains supply.
intended for direct connection
to a mains supply.
N/A
3.3.4
S (GB): The range of conductor sizes of flexible
cords to be accepted by terminals for equipment
with a
cords to be accepted by terminals for equipment
with a
RATED CURRENT
of over 10 A up to and
including 13 A is:
- 1,25 mm
- 1,25 mm
2
to 1,5 mm
2
nominal cross-sectional
area.
Class III equipment. Unit is not
intended for direct connection
to a mains supply.
intended for direct connection
to a mains supply.
N/A
4.3.6
S (GB): The torque test is performed using a
socket outlet complying with BS 1363 and the
plug part of
socket outlet complying with BS 1363 and the
plug part of
DIRECT PLUG
-
IN EQUIPMENT
shall be
assessed to BS 1363: Part 1, 12.1, 12.2, 12.3,
12.9, 12.11, 12.12, 12.16 and 12.17, except that
the test of 12.17 is performed at not less than
125
12.9, 12.11, 12.12, 12.16 and 12.17, except that
the test of 12.17 is performed at not less than
125
°C.
Not a Direct Plug-In Equipment.
N/A
S (IE): D
IRECT PLUG
-
IN EQUIPMENT
is known as
plug similar devices. Such devices shall comply
with Statutory Instrument 526:1997 – National
Standards Authority of Ireland (Section 28)
(Electrical plugs, plug similar devices and
sockets for domestic use) Regulations, 1997.
with Statutory Instrument 526:1997 – National
Standards Authority of Ireland (Section 28)
(Electrical plugs, plug similar devices and
sockets for domestic use) Regulations, 1997.
Not provided with Irish plug.
N/A
- Page 39 of 52 -
www.nemko.com
Report No. 46974
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
4.3.13.6
C: Add the following note:
NOTE Attention is drawn to 1999/519/EC: Council
Recommendation on the limitation of exposure of the general
public to electromagnetic fields 0 Hz to 300 GHz. Standards
taking into account this Recommendation are currently under
development.
Recommendation on the limitation of exposure of the general
public to electromagnetic fields 0 Hz to 300 GHz. Standards
taking into account this Recommendation are currently under
development.
Considered. N/A
6.1.2.1
S (FI, NO, SE): Add the following text between
the first and second paragraph:
If this insulation is solid, including insulation
forming part of a component, it shall at least
consist of either
- two layers of thin sheet material, each of which
shall pass the electric strength test below, or
- one layer having a distance through insulation
of at least 0,4 mm, which shall pass the electric
strength test below.
If this insulation forms part of a semiconductor
component (e.g. an optocoupler), there is no
distance through insulation requirement for the
insulation consisting of an insulating compound
completely filling the casing, so that
the first and second paragraph:
If this insulation is solid, including insulation
forming part of a component, it shall at least
consist of either
- two layers of thin sheet material, each of which
shall pass the electric strength test below, or
- one layer having a distance through insulation
of at least 0,4 mm, which shall pass the electric
strength test below.
If this insulation forms part of a semiconductor
component (e.g. an optocoupler), there is no
distance through insulation requirement for the
insulation consisting of an insulating compound
completely filling the casing, so that
CLEARANCES
and
CREEPAGE DISTANCES
do not exist, if the
component passes the electric strength test in
accordance with the compliance clause below
and in addition
- passes the tests and inspection criteria of
2.10.8 with an electric strength test of 1,5 kV
multiplied by 1,6 (the electric strength test of
2.10.7 shall be performed using 1,5 kV), and
- is subject to
accordance with the compliance clause below
and in addition
- passes the tests and inspection criteria of
2.10.8 with an electric strength test of 1,5 kV
multiplied by 1,6 (the electric strength test of
2.10.7 shall be performed using 1,5 kV), and
- is subject to
ROUTINE TESTING
for electric
strength during manufacturing, using a test
voltage of 1,5 kV.
It is permitted to bridge this insulation with a
capacitor complying with EN 132400:1994,
subclass Y2.
A capacitor classified Y3 according to
EN 132400:1994, may bridge this insulation
under the following conditions:
- the insulation requirements are satisfied by
having a capacitor classified Y3 as defined by
EN 132400, which in addition to the Y3 testing, is
tested with an impulse test of 2,5 kV defined in
EN 60950:2000, 6.2.2.1;
- the additional testing shall be performed on all
the test specimens as described in EN 132400;
- the impulse test of 2,5 kV is to be performed
voltage of 1,5 kV.
It is permitted to bridge this insulation with a
capacitor complying with EN 132400:1994,
subclass Y2.
A capacitor classified Y3 according to
EN 132400:1994, may bridge this insulation
under the following conditions:
- the insulation requirements are satisfied by
having a capacitor classified Y3 as defined by
EN 132400, which in addition to the Y3 testing, is
tested with an impulse test of 2,5 kV defined in
EN 60950:2000, 6.2.2.1;
- the additional testing shall be performed on all
the test specimens as described in EN 132400;
- the impulse test of 2,5 kV is to be performed
No TNV circuits.
N/A
- Page 40 of 52 -
www.nemko.com
Report No. 46974
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
before the endurance test in EN 132400, in the
sequence of tests as described in EN 132400.
sequence of tests as described in EN 132400.
6.1.2.2
S (FI, NO, SE): The exclusions are applicable for
PERMANENTLY CONNECTED EQUIPMENT
and
PLUGGABLE EQUIPMENT TYPE
B and equipment
intended to be used in a
RESTRICTED ACCESS
LOCATION
where equipotential bonding has been
applied, e.g. in a telecommunication centre, and
which has provision for a permanently connected
which has provision for a permanently connected
PROTECTIVE EARTHING CONDUCTOR
and is provided
with instructions for the installation of that
conductor by a service person.
conductor by a service person.
No TNV circuits.
N/A
7.1
S (FI, NO, SE): Requirements according to this
annex, 6.1.2.1 and 6.1.2.2 apply with the term
annex, 6.1.2.1 and 6.1.2.2 apply with the term
TELECOMMUNICATION NETWORK
in 6.1.2 being
replaced by the term
CABLE DISTRIBUTION SYSTEM
.
Not for connection to cable
distribution systems.
distribution systems.
N/A
G.2.1
S (NO): Due to the IT power distribution system
used (see annex V, Fig. V.7), the
used (see annex V, Fig. V.7), the
A
.
C
.
MAINS
SUPPLY
voltage is considered to be equal to the
line-to-line voltage, and will remain at 230 V in
case of a single earth fault.
case of a single earth fault.
Not used.
N/A
Annex H
C: Replace the last paragraph of this annex by:
At any point 10 cm from the surface of the
At any point 10 cm from the surface of the
OPERATOR ACCESS AREA
, the dose rate shall not
exceed 1
µSv/h (0,1 mR/h) (see note). Account is
taken of the background level.
Replace the notes as follows:
Replace the notes as follows:
NOTE These values appear in Directive 96/29/Euratom.
Delete Note 2.
The unit does not emit X-ray
radiation.
radiation.
N/A
Annex H
A (DE, Regulation on protection against hazards
by X-ray, of 8
by X-ray, of 8
th
January 1987, Article 5
[Operation of X-ray emission source], clauses 1
to 4):
a) A licence is required by those who operate an
X-ray emission source.
b) A licence in accordance with clause 1 is not
required by those who operate an X-ray emission
source on which the electron acceleration voltage
does not exceed 20 kV if
1) the local dose rate at a distance of 0,1 m
from the surface does not exceed 1 µSv/h and
2) it is adequately indicated on the X-ray
emission source that
i) X-rays are generated, and
ii) the electron acceleration voltage must not
to 4):
a) A licence is required by those who operate an
X-ray emission source.
b) A licence in accordance with clause 1 is not
required by those who operate an X-ray emission
source on which the electron acceleration voltage
does not exceed 20 kV if
1) the local dose rate at a distance of 0,1 m
from the surface does not exceed 1 µSv/h and
2) it is adequately indicated on the X-ray
emission source that
i) X-rays are generated, and
ii) the electron acceleration voltage must not
German A deviation withdrawn
according to Amd. A11:2004.
according to Amd. A11:2004.
N/A