JBL ON STAGEII (serv.man12) EMC - CB Certificate ▷ View online
- Page 41 of 52 -
www.nemko.com
Report No. 46974
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
exceed the maximum value stipulated by the
manufacturer
manufacturer
or
importer.
c) A licence in accordance with clause 1 is also
not required by persons who operate an X-ray
emission source on which the electron
acceleration voltage exceeds 20 kV if
1) the X-ray emission source has been granted
a type approval, and
2) it is adequately indicated on the X-ray
emission source that
i) X-rays are generated
ii) the device stipulated by the manufacturer or
importer guarantees that the maximum
permissible local dose rate in accordance with
the type approval is not exceeded, and
iii) the electron acceleration voltage must not
exceed the maximum value stipulated by the
manufacturer
not required by persons who operate an X-ray
emission source on which the electron
acceleration voltage exceeds 20 kV if
1) the X-ray emission source has been granted
a type approval, and
2) it is adequately indicated on the X-ray
emission source that
i) X-rays are generated
ii) the device stipulated by the manufacturer or
importer guarantees that the maximum
permissible local dose rate in accordance with
the type approval is not exceeded, and
iii) the electron acceleration voltage must not
exceed the maximum value stipulated by the
manufacturer
or
importer.
d) Furthermore, a licence in accordance with
clause 1 is also not required by persons who
operate X-ray emission sources on which the
electron acceleration voltage does not exceed
30 kV if
1) the X-rays are generated only by intrinsically
safe CRTs complying with Enclosure III, No. 6,
2) the values stipulated in accordance with
Enclosure III, No. 6.2 are limited by technical
measures and specified in the device, and
3) it is adequately indicated on the X-ray
emission source that the X-rays generated are
adequately screened by the intrinsically safe
CRT.
clause 1 is also not required by persons who
operate X-ray emission sources on which the
electron acceleration voltage does not exceed
30 kV if
1) the X-rays are generated only by intrinsically
safe CRTs complying with Enclosure III, No. 6,
2) the values stipulated in accordance with
Enclosure III, No. 6.2 are limited by technical
measures and specified in the device, and
3) it is adequately indicated on the X-ray
emission source that the X-rays generated are
adequately screened by the intrinsically safe
CRT.
Annex P
C: Replace the text of this annex by:
See annex ZA.
See annex ZA.
Considered. —
Annex Q
C: Replace the title of IEC 61032 by "Protection of persons and equipment by
enclosures – Probes for verification".
Add the following notes for the standards indicated:
enclosures – Probes for verification".
Add the following notes for the standards indicated:
—
- Page 42 of 52 -
www.nemko.com
Report No. 46974
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
Annex ZA C: NORMATIVE REFERENCES TO INTERNATIONAL PUBLICATIONS WITH
NOTE When an international publication has been modified by common modifications, indicated by
(mod), the relevant EN/HD applies.
(mod), the relevant EN/HD applies.
—
IEC 60050-151
IEC 60050-195
EN 60065:1998 + corr. June 1999
IEC 60065 (mod):1998
EN 60073:1996
IEC 60073:1996
HD 566 S1:1990
IEC 60085:1984
HD 214 S2:1980
IEC 60112:1979
HD
611.4.1.S1:1992
IEC
60216-4-1:1990
HD
21
1)
Series
IEC 60227 (mod) Series
HD
22
2)
Series
IEC 60245 (mod) Series
EN 60309 Series
IEC 60309 Series
EN 60317-43:1997
IEC 60317-43:1997
EN 60320 Series
IEC 60320 (mod) Series
HD 384.3 S2:1995
IEC 60364-3 (mod):1993
HD 384.4.41 S2:1996
IEC 60364-4-41 (mod):1992
3)
EN
132400:1994
4)
+ A2:1998 + A3:1998 + A4:2001
IEC 60384-14:1993
EN 60417-1
IEC 60417-1
HD 625.1 S1:1996 + corr. Nov. 1996
IEC 60664-1 (mod):1992
EN 60695-2-2:1994
IEC 60695-2-2:1991
EN 60695-2-11:2001
IEC 60695-2-11:2000
IEC 60695-2-20:1995
IEC 60695-10-2:1995
IEC 60695-11-3:2000
IEC 60695-11-4:2000
EN
60695-11-10:1999
IEC
60695-11-10:1999
EN 60695-11-20:1999
IEC 60695-11-20:1999
EN 60730-1:2000
IEC 60730-1:1999 (mod)
EN 60825-1:1994 + corr. Febr. 1995 +
A11:1996 + corr. July 1997
A11:1996 + corr. July 1997
IEC 60825-1:1993
EN 60825-2:2000
IEC 60825-2:2000
IEC 60825-9:1999
EN 60851-3:1996
IEC 60851-3:1996
EN 60851-5:1996
IEC 60851-5:1996
EN 60851-6:1996
IEC 60851-6:1996
IEC 60885-1:1987
EN 60990:1999
IEC 60990:1999
IEC 61058-1:2000
EN 61965:2001
IEC 61965:2000
- Page 43 of 52 -
www.nemko.com
Report No. 46974
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
EN ISO 178:1996
ISO 178:1993
EN ISO 179 Series
ISO 179 Series
EN ISO 180:2000
ISO 180:1993
ISO 261:1998
ISO 262:1998
EN ISO 527 Series
ISO 527 Series
ISO 3864:1984
EN ISO 4892 Series
ISO 4892 Series
ISO 7000:1989
EN ISO 8256:1996
ISO 8256:1990
ISO 9772:1994
EN ISO 9773:1998
ISO 9773:1998
ITU-T:1988 Recommendation K.17
ITU-T:2000 Recommendation K.21
1) The HD 21 series is related to, but not directly equivalent with the IEC 60227 series
2) The HD 22 series is related to, but not directly equivalent with the IEC 60245 series
3) IEC 60364-4-41:1992 is superseded by IEC 60364-4-41:2001
4) EN 132400, Sectional Specification: Fixed capacitors for electromagnetic interference suppression
and connection to the supply mains (Assessment level D), and its amendments are related to, but not
directly equivalent to IEC 60384-14
2) The HD 22 series is related to, but not directly equivalent with the IEC 60245 series
3) IEC 60364-4-41:1992 is superseded by IEC 60364-4-41:2001
4) EN 132400, Sectional Specification: Fixed capacitors for electromagnetic interference suppression
and connection to the supply mains (Assessment level D), and its amendments are related to, but not
directly equivalent to IEC 60384-14
- Page 44 of 52 -
www.nemko.com
Report No. 46974
TRF No.:IECEN60950_1B
1.5.1
TABLE: list of critical components
P
object/part No. manufacturer/
trademark
type/model
technical data standard
mark(s) of
conformity
conformity
1
)
Enclosure DOW
Emerge 4330-22
Flame
class
min HB
UL 94
UL
Alternative
enclosure
enclosure
Various Various
PVC
30 V, 80ºC
Evaluated in unit
UL
Alternative
Various
Various
30 V, 80ºC
Various Various
Flame
class
min V-2
UL 94
UL
PCB material
Various
Various
Flame class
min V-1 or
better, 105ºC
min V-1 or
better, 105ºC
Evaluated in unit
UL
Power amplifier
IC
IC
ST Microelectronics TDA2007A
6 W x 6 output Evaluated in unit
None
Speaker (4)
Various
1 inch,
magnetically
shielded
magnetically
shielded
6.8
Ω
Evaluated in unit
None
supplementary information:
1
) an asterisk indicates a mark which assures the agreed level of surveillance
Click on the first or last page to see other ON STAGEII (serv.man12) service manuals if exist.