DOWNLOAD JBL ON STAGEII (serv.man12) Service Manual ↓ Size: 1.19 MB | Pages: 77 in PDF or view online for FREE

Model
ON STAGEII (serv.man12)
Pages
77
Size
1.19 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
on-stageii-sm12.pdf
Date

JBL ON STAGEII (serv.man12) EMC - CB Certificate ▷ View online

 
 
- Page 21 of 52 - 
 
 
www.nemko.com
 
Report No.  46974 
 
 
TRF No.:IECEN60950_1B 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 Swing 
test 
 
 
4.2.6 Drop 
test 
 
 
4.2.7 Stress 
relief 
test 
 
 
4.2.8 
Cathode ray tubes 
No cathode ray tubes. 
N/A 
 
Picture tube separately certified..........................:   
 
4.2.9 
High pressure lamps 
 
 
4.2.10 Wall 
or 
ceiling 
mounted equipment; force (N) ....:  Not intended for wall or ceiling 
mounting. 
N/A 
 
4.3 
Design and construction  
 
4.3.1 
Edges and corners 
No edges and corners. 
N/A 
4.3.2 
Handles and manual controls; force (N) ............ :  No knobs, grips, handles, lever 
etc. 
N/A 
4.3.3 
Adjustable controls  
No hazardous adjustable 
controls. 
N/A 
4.3.4 
Securing of parts 
No hazards associated with 
loosening parts. 
N/A 
4.3.5 
Connection of plugs and sockets 
SELV connectors do not 
comply with IEC 60320 or IEC 
60083. 
N/A 
4.3.6 
Direct plug-in equipment 
Not intended to plug directly 
into a wall socket-outlet. 
N/A 
 
Dimensions (mm) of mains plug for direct plug-in   
.............................................................................: 
 
 
 
Torque and pull test of mains plug for direct 
plug-in; torque (Nm); pull (N)...............................: 
 
 
4.3.7 
Heating elements in earthed equipment 
No heating elements provided. 
N/A 
4.3.8 
Batteries 
No batteries in the equipment. 
N/A 
4.3.9 
Oil and grease 
Insulation is not exposed to oil, 
grease etc. 
N/A 
4.3.10 
Dust, powders, liquids and gases 
The equipment does not 
generate ionizing radiation or 
use a laser, and does not 
contain flammable liquids or 
gases. 
N/A 
4.3.11 
Containers for liquids or gases 
No containers for liquids or 
gases in the equipment. 
N/A 
4.3.12 
Flammable liquids .............................................. :  The equipment does not 
contain flammable liquid. 
N/A 
 
 
- Page 22 of 52 - 
 
 
www.nemko.com
 
Report No.  46974 
 
 
TRF No.:IECEN60950_1B 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
Quantity of liquid (l) ............................................ :   
 
 
Flash point (
°C) .................................................. :   
 
4.3.13 
Radiation; type of radiation  ............................... :  The equipment does not 
generate ionizing radiation or 
use a laser, and does not 
contain flammable liquids or 
gases.  LEDs are diffused type.
N/A 
4.3.13.1 General 
 
 
4.3.13.2 Ionizing 
radiation 
 
 
 
 Measured 
radiation 
(pA/kg) 
................................. :  
— 
 Measured 
high-voltage 
(kV) 
................................ :  
— 
 
Measured focus voltage (kV)  .............................. :  
— 
 CRT 
markings 
..................................................... :  
— 
4.3.13.3 
Effect of ultraviolet (UV) radiation on materials 
 
 
 
Part, property, retention after test, flammability 
classification ........................................................ :
 
 
4.3.13.4 
Human exposure to ultraviolet (UV) radiation ..... :  
 
4.3.13.5 
Laser (including LEDs) 
No laser components, LEDs 
are diffuse type. 
N/A 
 Laser 
class 
.......................................................... :  
— 
4.3.13.6 
Other types .......................................................... : No other parts of radiation. 
N/A 
 
4.4 
Protection against hazardous moving parts 
N/A 
4.4.1 
General 
No hazardous moving parts. 
 
4.4.2 
Protection in operator access areas 
 
 
4.4.3 
Protection in restricted access locations  
 
 
4.4.4 
Protection in service access areas 
 
 
 
4.5 Thermal 
requirements 
 
4.5.1 
Maximum temperatures 
(see appended table 4.5) 
 
 
- Page 23 of 52 - 
 
 
www.nemko.com
 
Report No.  46974 
 
 
TRF No.:IECEN60950_1B 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
Normal load condition per Annex L .....................:  Normal operation is considered 
1/8th of maximum undistorted. 
Non-clipping was determined 
using a 1 KHz sinusoidal signal 
input. For maximum normal 
operation, 1/8th of the non-
clipping amplitude was used 
with a filtered pink noise input 
signal. 
4.5.2 
Resistance to abnormal heat 
No thermoplastic parts carrying 
hazardous voltages. 
N/A 
 
4.6 Openings 
in 
enclosures 
 
4.6.1 
Top and side openings 
No top and side openings. 
N/A 
 Dimensions 
(mm) 
...............................................: 
 
— 
4.6.2 
Bottoms of fire enclosures 
No bottom openings. 
N/A 
 
Construction of the bottom..................................:   
— 
4.6.3 
Doors or covers in fire enclosures 
No doors or covers provided. 
N/A 
4.6.4 
Openings in transportable equipment 
The unit is not regarded as 
transportable equipment. 
N/A 
4.6.5 
Adhesives for constructional purposes 
No barrier secured by adhesive 
inside enclosure. 
N/A 
 
Conditioning temperature (
°C)/time (weeks).......:   
— 
 
4.7 
Resistance to fire 
 
4.7.1 
Reducing the risk of ignition and spread of flame 
Equipment is class III 
equipment, powered from a 
LPS. 
 
Method 1, selection and application of 
components wiring and materials 
Equipment is class III 
equipment, powered from a 
LPS. 
 
Method 2, application of all of simulated fault 
condition tests 
 N/A 
4.7.2 
Conditions for a fire enclosure 
Equipment is class III 
equipment, powered from a 
LPS. Fire enclosure is not 
considered necessary. 
N/A 
4.7.2.1 
Parts requiring a fire enclosure 
Refer to 4.7.2. 
N/A 
 
 
- Page 24 of 52 - 
 
 
www.nemko.com
 
Report No.  46974 
 
 
TRF No.:IECEN60950_1B 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
4.7.2.2 
Parts not requiring a fire enclosure 
Equipment is class III powered 
from a LPS. Additionally all 
components are mounted on V-
1 or better material. 
4.7.3 Materials 
 
4.7.3.1 General 
Components 
and 
materials 
have adequate flammability 
classification. See appended 
table 1.5.1. 
4.7.3.2 
Materials for fire enclosures 
Fire enclosure not required, 
refer to 4.7.2. 
N/A 
4.7.3.3 
Materials for components and other parts outside 
fire enclosures 
Fire enclosure not required, 
enclosure is rated HB min. 
4.7.3.4 
Materials for components and other parts inside 
fire enclosures 
Fire enclosure not required, 
refer to 4.7.2. 
N/A 
4.7.3.5 
Materials for air filter assemblies 
No air filters in the equipment. 
N/A 
4.7.3.6 
Materials used in high-voltage components 
No parts exceeding 4kV. 
N/A 
 
ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS 
N/A 
5.1 
Touch current and protective conductor current 
 
5.1.1 
General 
Class III equipment. Unit is not 
intended for direct connection 
to a mains supply. No test 
considered necessary 
 
5.1.2 Equipment 
under 
test 
(EUT) 
 
 
5.1.3 Test 
circuit 
 
 
5.1.4 
Application of measuring instrument 
 
 
5.1.5 Test 
procedure 
 
 
5.1.6 Test 
measurements 
 
 
 
Test voltage (V) ................................................. :   
— 
 
Measured touch current (mA)  ........................... :   
— 
 
Max. allowed touch current (mA)  ...................... :   
— 
 
Measured protective conductor current (mA)  ... :   
— 
 
Max. allowed protective conductor current (mA) :   
— 
5.1.7 
Equipment with touch current exceeding 3.5 mA   
........................................................................... : 
 
 
Page of 77
Display