JBL ON STAGEII (serv.man12) EMC - CB Certificate ▷ View online
- Page 21 of 52 -
www.nemko.com
Report No. 46974
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
Swing
test
—
4.2.6 Drop
test
—
4.2.7 Stress
relief
test
—
4.2.8
Cathode ray tubes
No cathode ray tubes.
N/A
Picture tube separately certified..........................:
—
4.2.9
High pressure lamps
—
4.2.10 Wall
or
ceiling
mounted equipment; force (N) ....: Not intended for wall or ceiling
mounting.
N/A
4.3
Design and construction
—
4.3.1
Edges and corners
No edges and corners.
N/A
4.3.2
Handles and manual controls; force (N) ............ : No knobs, grips, handles, lever
etc.
N/A
4.3.3
Adjustable controls
No hazardous adjustable
controls.
controls.
N/A
4.3.4
Securing of parts
No hazards associated with
loosening parts.
loosening parts.
N/A
4.3.5
Connection of plugs and sockets
SELV connectors do not
comply with IEC 60320 or IEC
60083.
comply with IEC 60320 or IEC
60083.
N/A
4.3.6
Direct plug-in equipment
Not intended to plug directly
into a wall socket-outlet.
into a wall socket-outlet.
N/A
Dimensions (mm) of mains plug for direct plug-in
.............................................................................:
—
Torque and pull test of mains plug for direct
plug-in; torque (Nm); pull (N)...............................:
plug-in; torque (Nm); pull (N)...............................:
—
4.3.7
Heating elements in earthed equipment
No heating elements provided.
N/A
4.3.8
Batteries
No batteries in the equipment.
N/A
4.3.9
Oil and grease
Insulation is not exposed to oil,
grease etc.
grease etc.
N/A
4.3.10
Dust, powders, liquids and gases
The equipment does not
generate ionizing radiation or
use a laser, and does not
contain flammable liquids or
gases.
generate ionizing radiation or
use a laser, and does not
contain flammable liquids or
gases.
N/A
4.3.11
Containers for liquids or gases
No containers for liquids or
gases in the equipment.
gases in the equipment.
N/A
4.3.12
Flammable liquids .............................................. : The equipment does not
contain flammable liquid.
N/A
- Page 22 of 52 -
www.nemko.com
Report No. 46974
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
Quantity of liquid (l) ............................................ :
—
Flash point (
°C) .................................................. :
—
4.3.13
Radiation; type of radiation ............................... : The equipment does not
generate ionizing radiation or
use a laser, and does not
contain flammable liquids or
gases. LEDs are diffused type.
use a laser, and does not
contain flammable liquids or
gases. LEDs are diffused type.
N/A
4.3.13.1 General
—
4.3.13.2 Ionizing
radiation
—
Measured
radiation
(pA/kg)
................................. :
—
Measured
high-voltage
(kV)
................................ :
—
Measured focus voltage (kV) .............................. :
—
CRT
markings
..................................................... :
—
4.3.13.3
Effect of ultraviolet (UV) radiation on materials
—
Part, property, retention after test, flammability
classification ........................................................ :
classification ........................................................ :
—
4.3.13.4
Human exposure to ultraviolet (UV) radiation ..... :
—
4.3.13.5
Laser (including LEDs)
No laser components, LEDs
are diffuse type.
are diffuse type.
N/A
Laser
class
.......................................................... :
—
4.3.13.6
Other types .......................................................... : No other parts of radiation.
N/A
4.4
Protection against hazardous moving parts
N/A
4.4.1
General
No hazardous moving parts.
—
4.4.2
Protection in operator access areas
—
4.4.3
Protection in restricted access locations
—
4.4.4
Protection in service access areas
—
4.5 Thermal
requirements
—
4.5.1
Maximum temperatures
(see appended table 4.5)
P
- Page 23 of 52 -
www.nemko.com
Report No. 46974
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
Normal load condition per Annex L .....................: Normal operation is considered
1/8th of maximum undistorted.
Non-clipping was determined
using a 1 KHz sinusoidal signal
input. For maximum normal
operation, 1/8th of the non-
clipping amplitude was used
with a filtered pink noise input
signal.
Non-clipping was determined
using a 1 KHz sinusoidal signal
input. For maximum normal
operation, 1/8th of the non-
clipping amplitude was used
with a filtered pink noise input
signal.
P
4.5.2
Resistance to abnormal heat
No thermoplastic parts carrying
hazardous voltages.
hazardous voltages.
N/A
4.6 Openings
in
enclosures
—
4.6.1
Top and side openings
No top and side openings.
N/A
Dimensions
(mm)
...............................................:
—
4.6.2
Bottoms of fire enclosures
No bottom openings.
N/A
Construction of the bottom..................................:
—
4.6.3
Doors or covers in fire enclosures
No doors or covers provided.
N/A
4.6.4
Openings in transportable equipment
The unit is not regarded as
transportable equipment.
transportable equipment.
N/A
4.6.5
Adhesives for constructional purposes
No barrier secured by adhesive
inside enclosure.
inside enclosure.
N/A
Conditioning temperature (
°C)/time (weeks).......:
—
4.7
Resistance to fire
4.7.1
Reducing the risk of ignition and spread of flame
Equipment is class III
equipment, powered from a
LPS.
equipment, powered from a
LPS.
P
Method 1, selection and application of
components wiring and materials
components wiring and materials
Equipment is class III
equipment, powered from a
LPS.
equipment, powered from a
LPS.
P
Method 2, application of all of simulated fault
condition tests
condition tests
N/A
4.7.2
Conditions for a fire enclosure
Equipment is class III
equipment, powered from a
LPS. Fire enclosure is not
considered necessary.
equipment, powered from a
LPS. Fire enclosure is not
considered necessary.
N/A
4.7.2.1
Parts requiring a fire enclosure
Refer to 4.7.2.
N/A
- Page 24 of 52 -
www.nemko.com
Report No. 46974
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
4.7.2.2
Parts not requiring a fire enclosure
Equipment is class III powered
from a LPS. Additionally all
components are mounted on V-
1 or better material.
from a LPS. Additionally all
components are mounted on V-
1 or better material.
P
4.7.3 Materials
—
4.7.3.1 General
Components
and
materials
have adequate flammability
classification. See appended
table 1.5.1.
classification. See appended
table 1.5.1.
P
4.7.3.2
Materials for fire enclosures
Fire enclosure not required,
refer to 4.7.2.
refer to 4.7.2.
N/A
4.7.3.3
Materials for components and other parts outside
fire enclosures
fire enclosures
Fire enclosure not required,
enclosure is rated HB min.
enclosure is rated HB min.
P
4.7.3.4
Materials for components and other parts inside
fire enclosures
fire enclosures
Fire enclosure not required,
refer to 4.7.2.
refer to 4.7.2.
N/A
4.7.3.5
Materials for air filter assemblies
No air filters in the equipment.
N/A
4.7.3.6
Materials used in high-voltage components
No parts exceeding 4kV.
N/A
5
ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS
N/A
5.1
Touch current and protective conductor current
—
5.1.1
General
Class III equipment. Unit is not
intended for direct connection
to a mains supply. No test
considered necessary
intended for direct connection
to a mains supply. No test
considered necessary
—
5.1.2 Equipment
under
test
(EUT)
—
5.1.3 Test
circuit
—
5.1.4
Application of measuring instrument
—
5.1.5 Test
procedure
—
5.1.6 Test
measurements
—
Test voltage (V) ................................................. :
—
Measured touch current (mA) ........................... :
—
Max. allowed touch current (mA) ...................... :
—
Measured protective conductor current (mA) ... :
—
Max. allowed protective conductor current (mA) :
—
5.1.7
Equipment with touch current exceeding 3.5 mA
........................................................................... :
—