JBL ON STAGEII (serv.man12) EMC - CB Certificate ▷ View online
- Page 9 of 52 -
www.nemko.com
Report No. 46974
TRF No.:IECEN60950_1B
Photographs: Continued
Bottom Side of PCB (before cut-out) (5)
Inside Top Half View (6)
- Page 10 of 52 -
www.nemko.com
Report No. 46974
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
1 GENERAL
1.5 Components
—
1.5.1 General
—
Comply with IEC 60950-1 or relevant component
standard
standard
(see appended table 1.5.1)
P
1.5.2
Evaluation and testing of components
Certified components are used
in accordance with their ratings,
certifications and they comply
with applicable parts of this
standard.
Components not certified are
used in accordance with their
ratings and they comply with
applicable parts of IEC 60950-1
and the relevant component
standard.
Components, for which no
relevant IEC-standard exists,
have been tested under the
conditions occurring in the
equipment, using applicable
parts of IEC 60950-1.
in accordance with their ratings,
certifications and they comply
with applicable parts of this
standard.
Components not certified are
used in accordance with their
ratings and they comply with
applicable parts of IEC 60950-1
and the relevant component
standard.
Components, for which no
relevant IEC-standard exists,
have been tested under the
conditions occurring in the
equipment, using applicable
parts of IEC 60950-1.
P
1.5.3
Thermal controls
No thermal controls.
N/A
1.5.4
Transformers
Class III equipment to be
supplied by a separately
approved power supply with an
SELV output. Power supply not
evaluated. Refer to Summary of
Testing.
supplied by a separately
approved power supply with an
SELV output. Power supply not
evaluated. Refer to Summary of
Testing.
N/A
1.5.5
Interconnecting cables
The interconnecting cables
contain only SELV.
contain only SELV.
P
1.5.6
Capacitors in primary circuits .............................: Class III equipment. No such
capacitors.
N/A
1.5.7
Double insulation or reinforced insulation bridged
by components
by components
No such components bridging
double or reinforced insulation.
double or reinforced insulation.
N/A
1.5.7.1
General
Class III equipment.
N/A
1.5.7.2 Bridging
capacitors
—
1.5.7.3 Bridging
resistors
—
1.5.7.4 Accessible
parts
- Page 11 of 52 -
www.nemko.com
Report No. 46974
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
1.5.8
Components in equipment for IT power systems
Class III equipment.
N/A
1.6 Power
interface
—
1.6.1 AC
power
distribution
systems
Class III equipment.
N/A
1.6.2
Input current
(see appended table 1.6.2)
P
1.6.3
Voltage limit of hand-held equipment
The equipment is not hand-
held.
held.
N/A
1.6.4
Neutral conductor
Class III equipment.
N/A
1.7
Markings and instructions
—
1.7.1
Power rating
The required marking is located
on the outside surface of the
equipment.
on the outside surface of the
equipment.
P
Rated voltage(s) or voltage range(s) (V) ...........: 18 VDC
P
Symbol for nature of supply, for d.c. only............: IEC 60417-1, symbol No. 5031,
is used.
P
Rated frequency or rated frequency range (Hz) : DC rated.
N/A
Rated current (mA or A) .....................................: 1.0 A
P
Manufacturer’s name or trademark or
identification mark ..............................................:
identification mark ..............................................:
P
Type/model or type reference .............................: on stage, on stage II
P
Symbol for Class II equipment only ...................: The equipment is Class III.
N/A
Other symbols ....................................................: The additional marking does
not give rise to
misunderstandings.
misunderstandings.
P
Certification marks .............................................: Refer to copy of markings.
—
1.7.2
Safety instructions
Provided with marking
regarding use of specified
power supply, refer to marking
label.
regarding use of specified
power supply, refer to marking
label.
P
1.7.3
Short duty cycles
The equipment is intended for
continuous operation.
continuous operation.
N/A
1.7.4
Supply voltage adjustment .................................: No voltage selector.
N/A
1.7.5
Power outlets on the equipment ........................: No standard power outlet.
N/A
1.7.6
Fuse identification ..............................................: No fuses.
N/A
1.7.7
Wiring terminals
Class III equipment.
N/A
1.7.7.1
Protective earthing and bonding terminals ........:
—
- Page 12 of 52 -
www.nemko.com
Report No. 46974
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
1.7.7.2
Terminal for a.c. mains supply conductors
—
1.7.7.3
Terminals for d.c. mains supply conductors
—
1.7.8
Controls and indicators
No controls or figures provided.
N/A
1.7.8.1
Identification, location and marking ....................:
—
1.7.8.2 Colours
...............................................................:
—
1.7.8.3 Symbols
.............................................................:
—
1.7.8.4
Markings using figures ......................................:
—
1.7.9
Isolation of multiple power sources ....................: Class III equipment.
N/A
1.7.10
IT power distribution systems
Class III equipment.
N/A
1.7.11
Thermostats and other regulating devices
No thermostats or other
regulating devices.
regulating devices.
N/A
1.7.12
Language ...........................................................: Instructions and markings shall
be in a language acceptable for
the country where the
equipment is to be sold.
English manual verified.
the country where the
equipment is to be sold.
English manual verified.
—
1.7.13 Durability
The
marking withstands
required tests.
P
1.7.14
Removable parts
No removable parts.
P
1.7.15
Replaceable batteries
No battery in the equipment.
N/A
Language ............................................................:
—
1.7.16
Operator access with a tool ................................: Class III equipment.
N/A
1.7.17
Equipment for restricted access locations ..........: Equipment not intended for
installation in RAL.
N/A
2 PROTECTION
FROM
HAZARDS
—
2.1
Protection from electric shock and energy hazards
—
2.1.1
Protection in operator access areas
Refer below:
—
2.1.1.1 Access
to
energized
parts
Class III equipment.
N/A
Test
by
inspection
..............................................:
—
Test with test finger ............................................:
—
Test with test pin ................................................:
—
Test with test probe ............................................:
—
2.1.1.2
Battery compartments ........................................: No TNV circuits in the
equipment.
N/A
2.1.1.3
Access to ELV wiring
No internal wiring at ELV.
N/A