DOWNLOAD JBL ON STAGEII (serv.man12) Service Manual ↓ Size: 1.19 MB | Pages: 77 in PDF or view online for FREE

Model
ON STAGEII (serv.man12)
Pages
77
Size
1.19 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
on-stageii-sm12.pdf
Date

JBL ON STAGEII (serv.man12) EMC - CB Certificate ▷ View online

 
 
- Page 13 of 52 - 
 
 
www.nemko.com
 
Report No.  46974 
 
 
TRF No.:IECEN60950_1B 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
Working voltage (V); minimum distance (mm) 
through insulation 
 
— 
2.1.1.4 
Access to hazardous voltage circuit wiring 
Class III equipment. 
N/A 
2.1.1.5 
Energy hazards  ..................................................:  Class III equipment, supplies 
from a LPS. 
N/A 
2.1.1.6 
Manual controls 
No shafts or knobs. 
N/A 
2.1.1.7 
Discharge of capacitors in equipment 
Class III equipment. 
N/A 
 
Time-constant (s); measured voltage (V) ...........:   
— 
2.1.2 
Protection in service access areas 
Class III equipment. 
N/A 
2.1.3 
Protection in restricted access locations 
Equipment not intended for 
installation in RAL. 
N/A 
 
2.2 SELV 
circuits 
 
2.2.1 
General requirements 
SELV limits are not exceeded 
under normal condition and 
after a single fault. Equipment 
is powered from a SELV 
source. 
2.2.2 
Voltages under normal conditions (V).................:  Powered by SELV source. 
2.2.3 
Voltages under fault conditions (V) .....................:  Powered by SELV source. 
N/A 
2.2.3.1 
Separation by double insulation or reinforced 
insulation (method 1) 
Powered by SELV source. 
N/A 
2.2.3.2 
Separation by earthed screen (method 2) 
Not used. 
N/A 
2.2.3.3 
Protection by earthing of the SELV circuit 
(method 3) 
Not used. 
N/A 
2.2.4 
Connection of SELV circuits to other circuits....... : SELV circuits are only 
connected to other SELV 
circuits and protective earth. 
 
2.3 TNV 
circuits 
N/A 
2.3.1 Limits 
Refer 
below: 
 
 
Type of TNV circuits............................................:  No TNV circuits. 
 
2.3.2 
Separation from other circuits and from 
accessible parts 
 
 
 Insulation 
employed ............................................: 
 
 
2.3.3 
Separation from hazardous voltages 
 
 
 Insulation 
employed ............................................: 
 
 
 
 
- Page 14 of 52 - 
 
 
www.nemko.com
 
Report No.  46974 
 
 
TRF No.:IECEN60950_1B 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
2.3.4 
Connection of TNV circuits to other circuits 
 
 
 Insulation 
employed ............................................: 
 
 
2.3.5 
Test for operating voltages generated externally 
No TNV circuits. 
 
 
2.4 Limited 
current 
circuits 
N/A 
2.4.1 
General requirements 
No limited current circuits. 
 
2.4.2 Limit 
values 
 
 
 Frequency 
(Hz) ...................................................: 
 
— 
 Measured 
current 
(mA) .......................................: 
 
— 
 Measured 
voltage 
(V)..........................................: 
 
— 
 
Measured capacitance (
µF) ................................:   
— 
2.4.3 
Connection of limited current circuits to other 
circuits 
 
 
 
2.5 
Limited power sources 
 
 Inherently 
limited 
output 
Class III equipment powered by 
Limited Power Source. 
Therefore all outputs are 
considered to be limited power. 
 Impedance 
limited 
output 
 
 
 
Overcurrent protective device limited output 
 
 
 
Regulating network limited output under normal 
operating and single fault condition 
 
 
 
Regulating network limited output under normal 
operating conditions and overcurrent protective 
device limited output under single fault condition 
 
 
 
Output voltage (V), output current (A), apparent 
power (VA) .........................................................: 
 
— 
 
Current rating of overcurrent protective device (A)  
— 
 
2.6 
Provisions for earthing and bonding 
N/A 
2.6.1 
Protective earthing 
Class III equipment. 
 
2.6.2 Functional 
earthing 
 
 
2.6.3 
Protective earthing and protective bonding 
conductors 
 
 
2.6.3.1 General 
 
 
 
 
- Page 15 of 52 - 
 
 
www.nemko.com
 
Report No.  46974 
 
 
TRF No.:IECEN60950_1B 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
2.6.3.2 
Size of protective earthing conductors 
 
 
 
Rated current (A), cross-sectional area (mm
2
), 
AWG....................................................................: 
 
— 
2.6.3.3 
Size of protective bonding conductors 
 
 
 
Rated current (A), cross-sectional area (mm
2
), 
AWG....................................................................: 
 
— 
2.6.3.4 
Resistance (
Ω) of earthing conductors and their 
terminations, test current (A)...............................: 
 
 
2.6.3.5 Colour 
of 
insulation .............................................: 
 
 
2.6.4 Terminals 
 
 
2.6.4.1 General 
 
 
2.6.4.2 
Protective earthing and bonding terminals 
 
 
 
Rated current (A), type and nominal thread 
diameter (mm).....................................................: 
 
— 
2.6.4.3 
Separation of the protective earthing conductor 
from protective bonding conductors 
 
 
2.6.5 
Integrity of protective earthing 
 
 
2.6.5.1 Interconnection 
of 
equipment 
 
 
2.6.5.2 
Components in protective earthing conductors 
and protective bonding conductors 
 
 
2.6.5.3 
Disconnection of protective earth 
 
 
2.6.5.4 
Parts that can be removed by an operator 
 
 
2.6.5.5 
Parts removed during servicing 
 
 
2.6.5.6 Corrosion 
resistance 
 
 
2.6.5.7 
Screws for protective bonding 
 
 
2.6.5.8 
Reliance on telecommunication network or cable 
distribution system 
 
 
 
2.7 
Overcurrent and earth fault protection in primary circuits 
N/A 
2.7.1 Basic 
requirements 
 
— 
 
Instructions when protection relies on building 
installation 
Class III equipment. 
— 
2.7.2 
Faults not covered in 5.3 
 
— 
2.7.3 
Short-circuit backup protection 
 
— 
2.7.4 
Number and location of protective devices ........:   
— 
2.7.5 
Protection by several devices 
 
— 
 
 
- Page 16 of 52 - 
 
 
www.nemko.com
 
Report No.  46974 
 
 
TRF No.:IECEN60950_1B 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
2.7.6 
Warning to service persons  ...............................:   
— 
 
2.8 Safety 
interlocks 
N/A 
2.8.1 
General principles 
No safety interlocks. 
— 
2.8.2 Protection 
requirements 
 
— 
2.8.3 Inadvertent 
reactivation 
 
— 
2.8.4 Fail-safe 
operation 
 
— 
2.8.5 Moving 
parts 
 
— 
2.8.6 Overriding 
 
 
— 
2.8.7 
Switches and relays  
 
— 
2.8.7.1 
Contact gaps (mm) ............................................. :   
— 
2.8.7.2 Overload 
test 
 
— 
2.8.7.3 Endurance 
test 
 
— 
2.8.7.4 
Electric strength test  
 
— 
2.8.8 Mechanical 
actuators 
 
— 
 
2.9 Electrical 
insulation 
— 
2.9.1 
Properties of insulating materials 
Class III equipment, only 
functional insulation provided. 
Refer also to clause 5.3.4. 
N/A 
2.9.2 
Humidity conditioning 
No test considered necessary. 
N/A 
 Humidity 
(%) 
.......................................................: 
 
— 
 
Temperature (
°C) ...............................................:   
— 
2.9.3 
Grade of insulation 
Insulation is considered to be 
functional insulation, and 
complies with clause 5.3.4 c). 
 
2.10 
Clearances, creepage distances and distances through insulation 
 
2.10.1 
General  
Equipment is class III powered 
from a secondary (SELV) circuit 
of a PSU. Only functional 
insulation is considered. 
2.10.2 
Determination of working voltage 
Class III equipment. 
N/A 
2.10.3 
Clearances 
Class III equipment. 
N/A 
2.10.3.1 General 
Refer 
below: 
 
2.10.3.2 
Clearances in primary circuits 
Class III equipment. 
N/A 
Page of 77
Display

Click on the first or last page to see other ON STAGEII (serv.man12) service manuals if exist.