JBL ON STAGEII (serv.man12) EMC - CB Certificate ▷ View online
- Page 33 of 52 -
www.nemko.com
Report No. 46974
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
CENELEC COMMON MODIFICATIONS [C], SPECIAL NATIONAL CONDITIONS [S] AND
A-DEVIATIONS (NATIONAL DEVIATIONS) [A] (EN 60950-1:2001 + A11:2004)
A-DEVIATIONS (NATIONAL DEVIATIONS) [A] (EN 60950-1:2001 + A11:2004)
General
C: Delete all the "country" notes in the reference
document according to the following list:
document according to the following list:
1.1.5
Note 2
1.5.8
Note 2
1.6.1 Note
1.7.2 Note
4 1.7.12 Note
2 2.1 Note
2.2.3
Note
2.2.4
Note
2.3.2 Note 2, 7, 8
2.3.3
Note 1, 2 2.3.4
Note 2,3 2.7.1 Note
2.10.3.1 Note 4
3.2.1.1 Note
3.2.3 Note 1, 2
3.2.5.1 Note
2
4.3.6
Note
1,2 4.7.2.2 Note
4.7.3.1 Note
2
6.1.2.1 Note
6.1.2.2 Note
6.2.2 Note
6.2.2.1 Note
2 6.2.2.2
Note
7 Note
4
7.1 Note
G2.1
Note 1, 2 Annex H Note 2
Considered.
—
1.2.4.1
S (DK): Certain types of Class I appliances (see
3.2.1.1) may be provided with a plug not
establishing earthing conditions when inserted
into Danish socket-outlets.
3.2.1.1) may be provided with a plug not
establishing earthing conditions when inserted
into Danish socket-outlets.
Class III equipment. Unit is not
intended for direct connection
to a mains supply.
intended for direct connection
to a mains supply.
N/A
1.5.1
A (SE, Ordinance 1990:944) and
(CH, Ordinance on environmentally hazardous
substances SR 814.013, Annex 3.2, Mercury):
Add the following:
(CH, Ordinance on environmentally hazardous
substances SR 814.013, Annex 3.2, Mercury):
Add the following:
NOTE – Switches containing mercury such as thermostats,
relays and level controllers are not allowed.
relays and level controllers are not allowed.
There are no components
containing mercury in the
equipment.
containing mercury in the
equipment.
N/A
1.5.8
S (NO): Due to the IT power system used (see
annex V, Fig. V.7), capacitors are required to be
rated for the applicable line-to-line voltage
(230 V).
annex V, Fig. V.7), capacitors are required to be
rated for the applicable line-to-line voltage
(230 V).
Class III equipment. Unit is not
intended for direct connection
to a mains supply.
intended for direct connection
to a mains supply.
N/A
1.7.2
S (FI, NO, SE): C
LASS
I
PLUGGABLE EQUIPMENT
TYPE
A intended for connection to other
equipment or a network shall, if safety relies on
connection to protective earth or if surge
suppressors are connected between the network
terminals and accessible parts, have a marking
stating that the equipment must be connected to
an earthed mains socket-outlet.
The marking text in the applicable countries shall
be as follows:
connection to protective earth or if surge
suppressors are connected between the network
terminals and accessible parts, have a marking
stating that the equipment must be connected to
an earthed mains socket-outlet.
The marking text in the applicable countries shall
be as follows:
Class III equipment. Unit is not
intended for direct connection
to a mains supply.
intended for direct connection
to a mains supply.
N/A
FI: "Laite on liitettävä suojamaadoitus-
koskettimilla varustettuun pistorasiaan"
koskettimilla varustettuun pistorasiaan"
—
NO: "Apparatet må tilkoples jordet stikkontakt"
—
SE: "Apparaten skall anslutas till jordat uttag"
—
A (DK, Heavy Current Regulations): Supply cords
of
of
CLASS
I
EQUIPMENT
, which is delivered without
a plug, must be provided with a visible tag with
the following text:
the following text:
Class III equipment. Unit is not
intended for direct connection
to a mains supply.
intended for direct connection
to a mains supply.
N/A
- Page 34 of 52 -
www.nemko.com
Report No. 46974
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
Vigtigt!
Lederen med grøn/gul isolation må kun tilsluttes
en klemme mærket
Lederen med grøn/gul isolation må kun tilsluttes
en klemme mærket
eller
If essential for the safety of the equipment, the
tag must in addition be provided with a diagram
which shows the connection of the other
conductors, or be provided with the following text:
"For tilslutning af de øvrige ledere, se
medfølgende installationsvejledning."
tag must in addition be provided with a diagram
which shows the connection of the other
conductors, or be provided with the following text:
"For tilslutning af de øvrige ledere, se
medfølgende installationsvejledning."
1.7.5
S (DK): Socket-outlets for providing power to
other equipment shall be in accordance with the
Heavy Current Regulations, Section 107-2-D1,
Standard Sheet DK 1-3a, DK 1-5a or DK 1-7a,
when used on Class I equipment. For
other equipment shall be in accordance with the
Heavy Current Regulations, Section 107-2-D1,
Standard Sheet DK 1-3a, DK 1-5a or DK 1-7a,
when used on Class I equipment. For
STATIONARY
EQUIPMENT
the socket-outlet shall be
in accordance with Standard Sheet DK 1-1b or
DK 1-5a.
DK 1-5a.
There are no socket outlets
providing power to other
appliances.
providing power to other
appliances.
N/A
1.7.5
A (DK, Heavy Current Regulations):
CLASS
II
EQUIPMENT
shall not be fitted with socket-
outlets for providing power to other equipment.
There are no socket-outlets
providing power to other
appliances.
providing power to other
appliances.
N/A
1.7.12
A (DE, Gesetz über technische Arbeitsmittel
(Gerätesicherheitsgesetz) [Law on technical
labour equipment {Equipment safety law}], of 23
(Gerätesicherheitsgesetz) [Law on technical
labour equipment {Equipment safety law}], of 23
rd
October 1992, Article 3, 3
rd
paragraph, 2
nd
sentence, together with the "Allgemeine
Verwaltungsvorschrift zur Durchführung des
Zweiten Abschnitts des Gerätesicherheits-
gesetzes" [General administrative regulation on
the execution of the Second Section of the
Equipment safety law], of 10
Verwaltungsvorschrift zur Durchführung des
Zweiten Abschnitts des Gerätesicherheits-
gesetzes" [General administrative regulation on
the execution of the Second Section of the
Equipment safety law], of 10
th
January 1996,
article 2, 4
th
paragraph item 2).
Directions for use with rules to prevent certain
hazards for (among others) maintenance of the
technical labour equipment, also for imported
technical labour equipment shall be written in the
German language.
hazards for (among others) maintenance of the
technical labour equipment, also for imported
technical labour equipment shall be written in the
German language.
NOTE: Of this requirement, rules for use even only by service
personnel are not exempted.
personnel are not exempted.
Must be considered before
marketed in Germany.
marketed in Germany.
—
1.7.15
A (CH, Ordinance on environmentally hazardous
substances SR 814.013):
Annex 4.10 of SR 814.013 applies for batteries.
substances SR 814.013):
Annex 4.10 of SR 814.013 applies for batteries.
There is no battery containing
Cd or Hg in the equipment.
Cd or Hg in the equipment.
N/A
2.2.4
S (NO): Requirements according to this annex,
1.7.2 and 6.1.2.1 apply.
1.7.2 and 6.1.2.1 apply.
No TNV circuits.
N/A
2.3.2
S (NO): Requirements according to this annex,
6.1.2.1 apply.
6.1.2.1 apply.
No TNV circuits.
N/A
- Page 35 of 52 -
www.nemko.com
Report No. 46974
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
2.3.3 and
2.3.4
2.3.4
S (NO): Requirements according to this annex,
1.7.2 and 6.1.2.1 apply.
1.7.2 and 6.1.2.1 apply.
No TNV circuits.
N/A
2.6.3.3
S (GB): The current rating of the circuit shall be
taken as 13 A, not 16 A.
taken as 13 A, not 16 A.
Class III equipment. Unit is not
intended for direct connection
to a mains supply.
intended for direct connection
to a mains supply.
N/A
2.7.1
C: Replace the subclause as follows:
Basic requirements
To protect against excessive current, short-
circuits and earth faults in
Basic requirements
To protect against excessive current, short-
circuits and earth faults in
PRIMARY CIRCUITS
,
protective devices shall be included either as
integral parts of the equipment or as parts of the
building installation, subject to the following, a),
b) and c):
a) except as detailed in b) and c), protective
devices necessary to comply with the
requirements of 5.3 shall be included as parts of
the equipment;
b) for components in series with the mains input
to the equipment such as the supply cord,
appliance coupler, r.f.i. filter and switch, short-
circuit and earth fault protection may be provided
by protective devices in the building installation;
c) it is permitted for
integral parts of the equipment or as parts of the
building installation, subject to the following, a),
b) and c):
a) except as detailed in b) and c), protective
devices necessary to comply with the
requirements of 5.3 shall be included as parts of
the equipment;
b) for components in series with the mains input
to the equipment such as the supply cord,
appliance coupler, r.f.i. filter and switch, short-
circuit and earth fault protection may be provided
by protective devices in the building installation;
c) it is permitted for
PLUGGABLE EQUIPMENT TYPE
B
or
PERMANENTLY CONNECTED EQUIPMENT
, to rely
on dedicated overcurrent and short-circuit
protection in the building installation, provided
that the means of protection, e.g. fuses or circuit
breakers, is fully specified in the installation
instructions.
If reliance is placed on protection in the building
installation, the installation instructions shall so
state, except that for
protection in the building installation, provided
that the means of protection, e.g. fuses or circuit
breakers, is fully specified in the installation
instructions.
If reliance is placed on protection in the building
installation, the installation instructions shall so
state, except that for
PLUGGABLE EQUIPMENT TYPE
A the building installation shall be regarded as
providing protection in accordance with the rating
of the wall socket outlet.
providing protection in accordance with the rating
of the wall socket outlet.
Class III equipment. Unit is not
intended for direct connection
to a mains supply.
intended for direct connection
to a mains supply.
N/A
S (GB): To protect against excessive currents
and short-circuits in the
and short-circuits in the
PRIMARY CIRCUIT
of
DIRECT PLUG
-
IN EQUIPMENT
, protective devices
shall be included as integral parts of the
DIRECT
PLUG
-
IN EQUIPMENT
.
Not a Direct Plug-In Equipment.
N/A
2.7.2 C:
Void.
Considered.
—
2.10.2
C: Replace in the first line "(see also 1.4.7)" by
"(see also 1.4.8)".
"(see also 1.4.8)".
Considered. —
- Page 36 of 52 -
www.nemko.com
Report No. 46974
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
2.10.3.1
S (NO): Due to the IT power distribution system
used (see annex V, Fig. V.7), the
used (see annex V, Fig. V.7), the
A
.
C
.
MAINS
SUPPLY
voltage is considered to be equal to the
line-to-line voltage and will remain at 230 V in
case of a single earth fault.
case of a single earth fault.
Class III equipment. Unit is not
intended for direct connection
to a mains supply.
intended for direct connection
to a mains supply.
N/A
3.2.1.1
S (CH): Supply cords of equipment having a
RATED CURRENT
not exceeding 10 A shall be
provided with a plug complying with SEV 1011 or
IEC 60884-1 and one of the following dimension
sheets:
IEC 60884-1 and one of the following dimension
sheets:
SEV 6532-2.1991, Plug Type 15, 3P+N+PE 250/400 V, 10 A
SEV 6533-2.1991, Plug Type 11, L+N
SEV 6533-2.1991, Plug Type 11, L+N
250 V, 10 A
SEV 6534-2.1991, Plug Type 12, L+N+PE 250 V, 10 A
In general, EN 60309 applies for plugs for
currents exceeding 10A. However, a 16 A plug
and socket-outlet system is being introduced in
Switzerland, the plugs of which are according to
the following dimension sheets, published in
February 1998:
currents exceeding 10A. However, a 16 A plug
and socket-outlet system is being introduced in
Switzerland, the plugs of which are according to
the following dimension sheets, published in
February 1998:
SEV 5932-2.1998, Plug Type 25, 3L+N+PE 230/400 V, 16 A
SEV 5933-2.1998, Plug Type 21, L+N
SEV 5933-2.1998, Plug Type 21, L+N
250 V, 16 A
SEV 5934-2.1998, Plug Type 23, L+N+PE 250 V, 16 A
Class III equipment. Unit is not
intended for direct connection
to a mains supply.
intended for direct connection
to a mains supply.
N/A
3.2.1.1
S (DK): Supply cords of single-phase equipment
having a rated current not exceeding 13 A shall
be provided with a plug according to the Heavy
Current Regulations, Section 107-2-D1.
C
having a rated current not exceeding 13 A shall
be provided with a plug according to the Heavy
Current Regulations, Section 107-2-D1.
C
LASS
I
EQUIPMENT
provided with socket-outlets
with earth contacts or which are intended to be
used in locations where protection against
indirect contact is required according to the
wiring rules shall be provided with a plug in
accordance with standard sheet DK 2-1a or
DK 2-5a.
If poly-phase equipment and single-phase
equipment having a
used in locations where protection against
indirect contact is required according to the
wiring rules shall be provided with a plug in
accordance with standard sheet DK 2-1a or
DK 2-5a.
If poly-phase equipment and single-phase
equipment having a
RATED CURRENT
exceeding
13 A is provided with a supply cord with a plug,
this plug shall be in accordance with the Heavy
Current Regulations, Section 107-2-D1 or
EN 60309-2.
this plug shall be in accordance with the Heavy
Current Regulations, Section 107-2-D1 or
EN 60309-2.
Class III equipment. Unit is not
intended for direct connection
to a mains supply.
intended for direct connection
to a mains supply.
N/A
Click on the first or last page to see other ON STAGEII (serv.man12) service manuals if exist.