Report
No.
98323
IEC 60950-1:2005 / EN 60950-1:2006
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IECEN60950_1C
1.5.7.4 Accessible
parts
N
1.5.8
Components in equipment for IT power systems
No components connected
between line and earth.
between line and earth.
N
1.5.9
Surge suppressors
See below.
—
1.5.9.1 General
See
below.
N
1.5.9.2
Protection of VDRs
No such parts.
N
1.5.9.3
Bridging of functional insulation by a VDR
No such parts.
N
1.5.9.4
Bridging of basic insulation by a VDR
No such parts.
N
1.5.9.5
Bridging of supplementary, double or reinforced
insulation by a VDR
insulation by a VDR
No such parts.
N
1.6 Power
interface
—
1.6.1
AC power distribution systems
Class III equipment.
N
1.6.2 Input
current
(see appended table 1.6.2)
P
1.6.3
Voltage limit of hand-held equipment
The equipment is not hand-
held.
held.
N
1.6.4
Neutral conductor
Class III equipment.
N
Measuring instrument
Inv. no.
Date
1.7
Marking and instructions
—
1.7.1
Power rating
The required marking is
located on the outside surface
of the equipment.
located on the outside surface
of the equipment.
P
Rated voltage(s) or voltage range(s) (V) ...............: 12V DC
—
Symbol for nature of supply, for d.c. only...............: IEC 60417-1, symbol No.
5031, is used.
P
Rated frequency or rated frequency range (Hz) ...: DC rated.
N
Rated current (mA or A) ........................................: 1.25A
P
Manufacturer’s name or trade-mark or identification
mark .......................................................................:
mark .......................................................................:
JBL P
Model identification or type reference ...................: jbl on stage - 200 iD
P
- Page 9 of 63 -
Report
No.
98323
IEC 60950-1:2005 / EN 60950-1:2006
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IECEN60950_1C
Symbol for Class II equipment only .......................: Class III equipment.
N
Other markings and symbols ................................: The
additional marking does
not give rise to
misunderstandings.
misunderstandings.
P
1.7.2
Safety instructions and marking
Provided with marking
regarding use of specified
power supply, refer to marking
label.
regarding use of specified
power supply, refer to marking
label.
P
1.7.2.1 General
Considered.
—
1.7.2.2
Disconnect devices
Class III equipment.
N
1.7.2.3 Overcurrent
protective device
Class III equipment.
N
1.7.2.4
IT power distribution systems
N
1.7.2.5
Operator access with a tool
Class III equipment.
N
1.7.2.6
Ozone
The equipment does not
produce Ozone.
produce Ozone.
N
1.7.3
Short duty cycles
The equipment is intended for
continuous operation.
continuous operation.
N
1.7.4
Supply voltage adjustment ...................................: No
voltage
selector. N
Methods and means of adjustment; reference to
installation instructions .........................................:
installation instructions .........................................:
N
1.7.5
Power outlets on the equipment ...........................:
No standard power outlet.
N
1.7.6
Fuse identification (marking, special fusing
characteristics, cross-reference) ..........................:
characteristics, cross-reference) ..........................:
No fuses.
N
1.7.7
Wiring terminals
Class III equipment
N
1.7.7.1 Protective
earthing and bonding terminals ...........:
—
1.7.7.2
Terminals for a.c. mains supply conductors
—
1.7.7.3
Terminals for d.c. mains supply conductors
—
1.7.8
Controls and indicators
Refer below.
—
1.7.8.1 Identification,
location
and marking ......................: No
controls. N
1.7.8.2 Colours
................................................................: For
functional indication a LED
lights when the equipment is
operating.
operating.
N
- Page 10 of 63 -
Report
No.
98323
IEC 60950-1:2005 / EN 60950-1:2006
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IECEN60950_1C
1.7.8.3
Symbols according to IEC 60417.........................:
The ON/OFF (push-push)
switch is marked with the
switch is marked with the
symbol "
" (IEC 60417-1 No.
5010).
P
1.7.8.4 Markings
using figures .......................................:
N
1.7.9
Isolation of multiple power sources .....................:
Class III equipment.
N
1.7.10
Thermostats and other regulating devices ..........:
No thermostats or other
regulating devices.
regulating devices.
N
1.7.11
Durability
The marking withstands
required tests.
required tests.
P
1.7.12
Removable parts
No removable parts.
N
1.7.13 Replaceable
batteries ..........................................:
No battery in the equipment.
N
Language(s)
........................................................:
⎯
1.7.14
Equipment for restricted access locations ...........:
Equipment not intended for
intallation in RAL.
intallation in RAL.
N
2
PROTECTION FROM HAZARDS
—
2.1
Protection from electric shock and energy hazards
—
2.1.1
Protection in operator access areas
Refer below:
—
2.1.1.1
Access to energized parts
Class III equipment.
N
Test by inspection .................................................:
—
Test with test finger (Figure 2A) ............................:
—
Test with test pin (Figure 2B) ................................:
—
Test with test probe (Figure 2C) ...........................:
—
2.1.1.2
Battery compartments
No TNV circuits in the
equipment.
equipment.
N
2.1.1.3
Access to ELV wiring
No internal wiring at ELV
accessible to the operator.
accessible to the operator.
N
Working voltage (Vpeak or Vrms); minimum
distance through insulation (mm)
distance through insulation (mm)
⎯
2.1.1.4
Access to hazardous voltage circuit wiring
Class III equipment.
N
2.1.1.5 Energy
hazards .....................................................:
Class III equipment, supplies
from a LPS.
from a LPS.
N
- Page 11 of 63 -
Report
No.
98323
IEC 60950-1:2005 / EN 60950-1:2006
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IECEN60950_1C
2.1.1.6
Manual controls
No shafts of knobs etc. at ELV
or hazardous voltage.
or hazardous voltage.
N
2.1.1.7
Discharge of capacitors in equipment
Class III equipment.
N
Measured voltage (V); time-constant (s)................:
⎯
2.1.1.8
Energy hazards – d.c. mains supply
Supplied from SELV.
N
a) Capacitor connected to the d.c. mains supply ..:
N
N
2.1.1.9 Audio
amplifiers .....................................................:
See 2.1.1.1.
P
2.1.2
Protection in service access areas
Class III equipment.
N
2.1.3
Protection in restricted access locations
Equipment not intended for
installation in RAL.
installation in RAL.
N
Measuring instrument
Inv. no.
Date
2.2 SELV
circuits
⎯
2.2.1
General requirements
SELV limits are not exceeded
under normal condition and
after a single fault. Equipment
is powered from a SELV
source.
under normal condition and
after a single fault. Equipment
is powered from a SELV
source.
P
2.2.2
Voltages under normal conditions (V) ................... :
Powered by SELV source.
P
2.2.3
Voltages under fault conditions (V) ....................... :
Powered by SELV source.
P
2.2.4
Connection of SELV circuits to other circuits ...... :
SELV circuits are not
connected to other circuits
than protective earth.
connected to other circuits
than protective earth.
P
Measuring instrument
Inv. no.
Date
2.3 TNV
circuits
⎯
2.3.1 Limits
⎯