JBL ON STAGE 200ID EMC - CB Certificate ▷ View online
- Page 28 of 63 -
Report
No.
98323
IEC 60950-1:2005 / EN 60950-1:2006
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IECEN60950_1C
4.7.2
Conditions for a fire enclosure
Equipment is class III
equipment, powered from a
LPS. Fire enclosure is not
considered necessary.
equipment, powered from a
LPS. Fire enclosure is not
considered necessary.
N
4.7.2.1
Parts requiring a fire enclosure
Refer to 4.7.2.
N
4.7.2.2
Parts not requiring a fire enclosure
Equipment is class III powered
from a LPS. Additionally all
components are mounted on V-
1 or better material.
from a LPS. Additionally all
components are mounted on V-
1 or better material.
P
4.7.3 Materials
⎯
4.7.3.1
General
Components and materials
have adequate flammability
classification. See appended
table 1.5.1.
have adequate flammability
classification. See appended
table 1.5.1.
P
4.7.3.2
Materials for fire enclosures
Fire enclosure not required,
refer to 4.7.2.
refer to 4.7.2.
N
4.7.3.3
Materials for components and other parts outside
fire enclosures
fire enclosures
Fire enclosure not required,
refer to 4.7.2.
refer to 4.7.2.
N
4.7.3.4
Materials for components and other parts inside fire
enclosures
enclosures
Fire enclosure not required,
refer to 4.7.2.
refer to 4.7.2.
N
4.7.3.5
Materials for air filter assemblies
No air filters in the equipment.
N
4.7.3.6
Materials used in high-voltage components
No parts exceeding 4kV.
N
Measuring instrument
Inv. no.
Date
5
ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS
⎯
5.1
Touch current and protective conductor current
⎯
5.1.1
General
Class III equipment. Unit is
not intended for direct
connection to a mains supply.
No test considered
necessary.
not intended for direct
connection to a mains supply.
No test considered
necessary.
N
5.1.2
Configuration of equipment under test (EUT)
N
5.1.2.1
Single connection to an a.c. mains supply
N
- Page 29 of 63 -
Report
No.
98323
IEC 60950-1:2005 / EN 60950-1:2006
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IECEN60950_1C
5.1.2.2
Redundant multiple connections to an a.c. mains
supply
supply
N
5.1.2.3
Simultaneous multiple connections to an a.c. mains
supply
supply
N
5.1.3 Test
circuit
N
5.1.4
Application of measuring instrument
N
5.1.5 Test
procedure
N
5.1.6 Test
measurements
N
Supply
voltage (V) ................................................:
⎯
Measured touch current (mA) ..............................:
⎯
Max. allowed touch current (mA) .........................:
⎯
Measured protective conductor current (mA) .......:
⎯
Max. allowed protective conductor current (mA)...:
⎯
5.1.7
Equipment with touch current exceeding 3,5 mA
N
5.1.7.1 General .................................................................:
N
5.1.7.2
Simultaneous multiple connections to the supply
N
5.1.8
Touch currents to telecommunication networks and
cable distribution systems and from
telecommunication networks
cable distribution systems and from
telecommunication networks
Not connected to a
telecommunication network
nor a cable distribution
system.
telecommunication network
nor a cable distribution
system.
N
5.1.8.1
Limitation of the touch current to a
telecommunication network or to a cable distribution
system
telecommunication network or to a cable distribution
system
N
Supply
voltage (V) ................................................:
⎯
Measured touch current (mA) ..............................:
⎯
Max. allowed touch current (mA) .........................:
⎯
5.1.8.2
Summation of touch currents from telecommunication
networks
networks
N
a) EUT with earthed telecommunication ports .....:
N
b) EUT whose telecommunication ports have no
reference to protective earth
reference to protective earth
N
- Page 30 of 63 -
Report
No.
98323
IEC 60950-1:2005 / EN 60950-1:2006
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IECEN60950_1C
Measuring instrument
Inv. no.
Date
5.2 Electric
strength
⎯
5.2.1
General
Functional insulation, no test
required.
required.
N
5.2.2
Test procedure
N
Measuring instrument
Inv. no.
Date
5.3
Abnormal operating and fault conditions
⎯
5.3.1
Protection against overload and abnormal operation
(see appended table 5.3)
P
5.3.2
Motors
There is no motor in the
equipment.
equipment.
N
5.3.3
Transformers
There are no safety
transformers in the
equipment.
transformers in the
equipment.
N
5.3.4 Functional
insulation .............................................: Complies with c).
P
5.3.5
Electromechanical components
No electromechanical
components in secondary
circuits.
components in secondary
circuits.
N
5.3.6
Audio amplifiers in ITE .........................................:
See the enclosed fault
condition tests.
condition tests.
P
5.3.7
Simulation of faults
See the enclosed fault
condition tests.
condition tests.
P
5.3.8 Unattended
equipment
No
thermostats, temperauter
limiters or thermal cut-outs.
N
5.3.9
Compliance criteria for abnormal operating and fault
conditions
conditions
See below.
P
5.3.9.1
During the tests
No fire or molten metal
occurred and no deformation
of enclosure during the tests.
occurred and no deformation
of enclosure during the tests.
P
- Page 31 of 63 -
Report
No.
98323
IEC 60950-1:2005 / EN 60950-1:2006
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IECEN60950_1C
5.3.9.2
After the tests
No hazard. Class III
equipment.
equipment.
P
Measuring instrument
Inv. no.
Date
6
CONNECTION TO TELECOMMUNICATION NETWORKS
⎯
6.1
Protection of telecommunication network service persons, and users of other
equipment connected to the network, from hazards in the equipment
equipment connected to the network, from hazards in the equipment
⎯
6.1.1
Protection from hazardous voltages
⎯
6.1.2
Separation of the telecommunication network from earth
⎯
6.1.2.1
Requirements
No TNV circuit.
N
Supply
voltage (V) ................................................:
⎯
Current in the test circuit (mA) ...........................:
⎯
6.1.2.2 Exclusions ............................................................:
N
Measuring instrument
Inv. no.
Date
6.2
Protection of equipment users from overvoltages on telecommunication networks
⎯
6.2.1 Separation
requirements
N
6.2.2
Electric strength test procedure
N
6.2.2.1 Impulse
test
N
6.2.2.2 Steady-state
test
N
6.2.2.3 Compliance
criteria
N
Measuring instrument
Inv. no.
Date