 Report 
No. 
98323 
 
 
IEC 60950-1:2005 / EN 60950-1:2006 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
 
TRF No. IECEN60950_1C 
 
 
4.7.2 
Conditions for a fire enclosure 
Equipment is class III 
equipment, powered from a 
LPS. Fire enclosure is not 
considered necessary.
 
4.7.2.1 
Parts requiring a fire enclosure 
Refer to 4.7.2.
 
4.7.2.2 
Parts not requiring a fire enclosure 
Equipment is class III powered 
from a LPS. Additionally all 
components are mounted on V-
1 or better material.
 
4.7.3 Materials 
⎯ 
4.7.3.1 
General 
Components and materials 
have adequate flammability 
classification. See appended 
table 1.5.1. 
4.7.3.2 
Materials for fire enclosures 
Fire enclosure not required, 
refer to 4.7.2.
 
4.7.3.3 
Materials for components and other parts outside 
fire enclosures 
Fire enclosure not required, 
refer to 4.7.2.
 
4.7.3.4 
Materials for components and other parts inside fire 
enclosures 
Fire enclosure not required, 
refer to 4.7.2.
 
4.7.3.5 
Materials for air filter assemblies 
No air filters in the equipment.
4.7.3.6 
Materials used in high-voltage components 
No parts exceeding 4kV. 
 
Measuring instrument 
Inv. no. 
Date 
 
 
 
 
 
 
 
ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS 
 
5.1 
Touch current and protective conductor current 
⎯ 
5.1.1 
General 
Class III equipment. Unit is 
not intended for direct 
connection to a mains supply. 
No test considered 
necessary. 
5.1.2 
Configuration of equipment under test (EUT) 
 
5.1.2.1 
Single connection to an a.c. mains supply 
 
 
 
- Page 29 of 63 - 
 
 
 Report 
No. 
98323 
 
 
IEC 60950-1:2005 / EN 60950-1:2006 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
 
TRF No. IECEN60950_1C 
 
 
5.1.2.2 
Redundant multiple connections to an a.c. mains 
supply 
 N 
5.1.2.3 
Simultaneous multiple connections to an a.c. mains 
supply 
 N 
5.1.3 Test 
circuit 
 
5.1.4 
Application of measuring instrument 
 
5.1.5 Test 
procedure 
 
5.1.6 Test 
measurements 
 
 Supply 
voltage (V)  ................................................:  
⎯ 
 
Measured touch current (mA)  ..............................: 
 
⎯ 
 
Max. allowed touch current (mA)  .........................: 
 
⎯ 
 
Measured protective conductor current (mA) .......: 
 
⎯ 
 
Max. allowed protective conductor current (mA)...: 
 
⎯ 
5.1.7 
Equipment with touch current exceeding 3,5 mA 
 
5.1.7.1 General .................................................................: 
 
5.1.7.2 
Simultaneous multiple connections to the supply 
 
5.1.8 
Touch currents to telecommunication networks and 
cable distribution systems and from 
telecommunication networks 
Not connected to a 
telecommunication network 
nor a cable distribution 
system. 
5.1.8.1 
Limitation of the touch current to a 
telecommunication network or to a cable distribution 
system 
 N 
 Supply 
voltage (V)  ................................................:  
⎯ 
 
Measured touch current (mA)  ..............................: 
 
⎯ 
 
Max. allowed touch current (mA)  .........................: 
 
⎯ 
5.1.8.2 
Summation of touch currents from telecommunication 
networks 
 N 
 
a) EUT with earthed telecommunication ports  .....: 
 
 
b) EUT whose telecommunication ports have no 
reference to protective earth 
 N 
 
 
 
- Page 30 of 63 - 
 
 
 Report 
No. 
98323 
 
 
IEC 60950-1:2005 / EN 60950-1:2006 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
 
TRF No. IECEN60950_1C 
 
 
Measuring instrument 
Inv. no. 
Date 
 
 
 
 
 
 
 
5.2 Electric 
strength 
⎯ 
5.2.1 
General 
Functional insulation, no test 
required. 
5.2.2 
Test procedure  
 
 
Measuring instrument 
Inv. no. 
Date 
 
 
 
 
 
 
 
5.3 
Abnormal operating and fault conditions 
⎯ 
5.3.1 
Protection against overload and abnormal operation 
(see appended table 5.3)  
5.3.2 
Motors 
There is no motor in the 
equipment. 
5.3.3 
Transformers 
There are no safety 
transformers in the 
equipment. 
5.3.4 Functional 
insulation .............................................: Complies with c). 
5.3.5 
Electromechanical components 
No electromechanical 
components in secondary 
circuits. 
5.3.6 
Audio amplifiers in ITE .........................................: 
See the enclosed fault 
condition tests. 
5.3.7 
Simulation of faults 
See the enclosed fault 
condition tests. 
5.3.8 Unattended 
equipment 
No 
thermostats, temperauter 
limiters or thermal cut-outs. 
5.3.9 
Compliance criteria for abnormal operating and fault 
conditions 
See below. 
5.3.9.1 
During the tests 
No fire or molten metal 
occurred and no deformation 
of enclosure during the tests. 
 
 
- Page 31 of 63 - 
 
 
 Report 
No. 
98323 
 
 
IEC 60950-1:2005 / EN 60950-1:2006 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
 
TRF No. IECEN60950_1C 
 
 
5.3.9.2 
After the tests 
No hazard. Class III 
equipment. 
 
Measuring instrument 
Inv. no. 
Date 
 
 
 
 
 
 
 
CONNECTION TO TELECOMMUNICATION NETWORKS 
⎯ 
6.1 
Protection of telecommunication network service persons, and users of other 
equipment connected to the network, from hazards in the equipment 
⎯ 
6.1.1 
Protection from hazardous voltages 
⎯ 
6.1.2 
Separation of the telecommunication network from earth 
⎯ 
6.1.2.1 
Requirements 
No TNV circuit. 
 Supply 
voltage (V)  ................................................:  
⎯ 
 
Current  in the test circuit  (mA)  ...........................: 
 
⎯ 
6.1.2.2 Exclusions ............................................................: 
 
 
Measuring instrument 
Inv. no. 
Date 
 
 
 
 
 
 
 
6.2 
Protection of equipment users from overvoltages on telecommunication networks 
⎯ 
6.2.1 Separation 
requirements 
 
6.2.2 
Electric strength test procedure 
 
6.2.2.1 Impulse 
test 
 
6.2.2.2 Steady-state 
test 
 
6.2.2.3 Compliance 
criteria 
 
 
Measuring instrument 
Inv. no. 
Date 
 
 
 
 
 
 
 
Page of 103