JBL ON STAGE 200ID EMC - CB Certificate ▷ View online
- Page 12 of 63 -
Report
No.
98323
IEC 60950-1:2005 / EN 60950-1:2006
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IECEN60950_1C
Type of TNV circuits............................................... :
No TNV circuit.
⎯
2.3.2
Separation from other circuits and from accessible
parts
parts
N
2.3.2.1 General
requirements
N
2.3.2.2
Protection by basic insulation
⎯
2.3.2.3
Protection by earthing
⎯
2.3.2.4
Protection by other constructions ......................... :
⎯
2.3.3
Separation from hazardous voltages
N
Insulation
employed ............................................... :
⎯
2.3.4
Connection of TNV circuits to other circuits
N
Insulation
employed ............................................... :
⎯
2.3.5
Test for operating voltages generated externally
N
Measuring instrument
Inv. no.
Date
2.4
Limited current circuits
N
2.4.1
General requirements
No limited current circuits.
⎯
2.4.2 Limit
values
⎯
Frequency
(Hz) ...................................................... :
⎯
Measured
current (mA) .......................................... :
⎯
Measured
voltage (V)............................................. :
⎯
Measured circuit capacitance (nF or µF) ............... :
⎯
2.4.3
Connection of limited current circuits to other
circuits
circuits
⎯
Measuring instrument
Inv. no.
Date
2.5
Limited power sources
⎯
- Page 13 of 63 -
Report
No.
98323
IEC 60950-1:2005 / EN 60950-1:2006
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IECEN60950_1C
a) Inherently limited output
Class III equipment powered
by Limited Power Source.
Therefore all outputs are
considered to be limited
power.
by Limited Power Source.
Therefore all outputs are
considered to be limited
power.
P
b) Impedance limited output
⎯
c) Regulating network limited output under normal
operating and single fault condition
operating and single fault condition
⎯
d) Overcurrent protective device limited output
⎯
Max. output voltage (V), max. output current (A),
max. apparent power (VA)..................................... :
max. apparent power (VA)..................................... :
⎯
Current rating of overcurrent protective device (A)
⎯
Measuring instrument
Inv. no.
Date
2.6
Provisions for earthing and bonding
⎯
2.6.1
Protective earthing
Class III equipment.
N
2.6.2 Functional
earthing
⎯
2.6.3
Protective earthing and protective bonding
conductors
conductors
⎯
2.6.3.1 General
⎯
2.6.3.2
Size of protective earthing conductors
⎯
Rated current (A), cross-sectional area (mm
2
),
AWG .......................................................................:
⎯
2.6.3.3
Size of protective bonding conductors
⎯
Rated current (A), cross-sectional area (mm
2
),
AWG .......................................................................:
⎯
2.6.3.4
Resistance of earthing conductors and their
terminations; resistance (
terminations; resistance (
Ω), voltage drop (V), test
current (A), duration (min) ......................................:
⎯
2.6.3.5 Colour
of insulation.................................................:
⎯
2.6.4 Terminals
—
2.6.4.1 General
—
- Page 14 of 63 -
Report
No.
98323
IEC 60950-1:2005 / EN 60950-1:2006
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IECEN60950_1C
2.6.4.2
Protective earthing and bonding terminals
—
Rated current (A), type, nominal thread diameter
(mm) .......................................................................:
(mm) .......................................................................:
—
2.6.4.3
Separation of the protective earthing conductor
from protective bonding conductors
from protective bonding conductors
—
2.6.5
Integrity of protective earthing
—
2.6.5.1
Interconnection of equipment
—
2.6.5.2
Components in protective earthing conductors and
protective bonding conductors
protective bonding conductors
—
2.6.5.3
Disconnection of protective earth
—
2.6.5.4
Parts that can be removed by an operator
—
2.6.5.5
Parts removed during servicing
—
2.6.5.6 Corrosion
resistance
—
2.6.5.7
Screws for protective bonding
—
2.6.5.8
Reliance on telecommunication network or cable
distribution system
distribution system
—
Measuring instrument
Inv. no.
Date
2.7
Overcurrent and earth fault protection in primary circuits
⎯
2.7.1 Basic
requirements
⎯
Instructions when protection relies on building
installation
installation
Class III equipment.
—
2.7.2
Faults not simulated in 5.3.7
⎯
2.7.3
Short-circuit backup protection
—
2.7.4
Number and location of protective devices .......... :
⎯
2.7.5
Protection by several devices
⎯
2.7.6 Warning
to
service personnel................................ :
—
2.8 Safety
interlocks
⎯
- Page 15 of 63 -
Report
No.
98323
IEC 60950-1:2005 / EN 60950-1:2006
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IECEN60950_1C
2.8.1
General principles
No safety interlocks.
N
2.8.2 Protection
requirements
⎯
2.8.3 Inadvertent
reactivation
—
2.8.4 Fail-safe
operation
⎯
2.8.5 Moving
parts
—
2.8.6 Overriding
⎯
2.8.7
Switches and relays
—
2.8.7.1 Contact
gaps (mm) ............................................... :
⎯
2.8.7.2 Overload
test
—
2.8.7.3 Endurance
test
⎯
2.8.7.4
Electric strength test
—
2.8.8 Mechanical
actuators
⎯
Measuring instrument
Inv. no.
Date
2.9 Electrical
insulation
⎯
2.9.1
Properties of insulating materials
Class III equipment, only
functional insulation provided.
Refer also to clause 5.3.4.
functional insulation provided.
Refer also to clause 5.3.4.
N
2.9.2
Humidity conditioning
No test considered necessary
N
Relative humidity (%), temperature (°C) ...............:
⎯
2.9.3
Grade of insulation
Insulation is considered to be
functional and complies with
5.3.4 c.
functional and complies with
5.3.4 c.
P
2.9.4
Separation from hazardous voltages
N
Method(s) used .....................................................:
⎯
Click on the first or last page to see other ON STAGE 200ID service manuals if exist.